Javascript must be enabled to continue!
ISO/CIE 11664-3:2019(E) Colorimetry ? Part 3: CIE tristimulus values
View through CrossRef
This document was prepared by the International Commission on Illumination (CIE) in cooperation with Technical Committee ISO/TC 274, Light and lighting. This first edition of ISO/CIE 11664-3 cancels and replaces ISO 11664-3:2012 | CIE S 014-3:2011, of which it constitutes a minor revision. The document has been editorially revised as per current ISO and CIE rules and the references have been updated.-\n--\n-The document specifies methods of calculating the tristimulus values of colour stimuli for which the spectral distributions are provided. These colour stimuli can be produced by self-luminous light sources or by reflecting or transmitting objects. This document requires that the colour stimulus function be tabulated at measurement intervals of 5 nm or less in a wavelength range of at least 380 nm to 780 nm. Extrapolation methods are suggested for cases where the measured wavelength range is less than 380 nm to 780 nm. The standard method is defined as summation at 1 nm intervals over the wavelength range from 360 nm to 830 nm. Alternative abridged methods are defined for larger intervals (up to 5 nm) and shorter ranges (down to 380 nm to 780 nm). The alternative methods are to be used only when appropriate and when the user has reviewed the impact on the final results. This document can be used in conjunction with the CIE 1931 standard colorimetric observer or the CIE 1964 standard colorimetric observer.
International Commission on Illumination (CIE)
Title: ISO/CIE 11664-3:2019(E) Colorimetry ? Part 3: CIE tristimulus values
Description:
This document was prepared by the International Commission on Illumination (CIE) in cooperation with Technical Committee ISO/TC 274, Light and lighting.
This first edition of ISO/CIE 11664-3 cancels and replaces ISO 11664-3:2012 | CIE S 014-3:2011, of which it constitutes a minor revision.
The document has been editorially revised as per current ISO and CIE rules and the references have been updated.
-\n--\n-The document specifies methods of calculating the tristimulus values of colour stimuli for which the spectral distributions are provided.
These colour stimuli can be produced by self-luminous light sources or by reflecting or transmitting objects.
This document requires that the colour stimulus function be tabulated at measurement intervals of 5 nm or less in a wavelength range of at least 380 nm to 780 nm.
Extrapolation methods are suggested for cases where the measured wavelength range is less than 380 nm to 780 nm.
The standard method is defined as summation at 1 nm intervals over the wavelength range from 360 nm to 830 nm.
Alternative abridged methods are defined for larger intervals (up to 5 nm) and shorter ranges (down to 380 nm to 780 nm).
The alternative methods are to be used only when appropriate and when the user has reviewed the impact on the final results.
This document can be used in conjunction with the CIE 1931 standard colorimetric observer or the CIE 1964 standard colorimetric observer.
Related Results
CIE S 014-3:2011 Colorimetry - Part 3: CIE Tristimulus Values
CIE S 014-3:2011 Colorimetry - Part 3: CIE Tristimulus Values
Superseded by Colorimetry - Part 3: CIE Tristimulus Values, 2nd Edition-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 11664-3:2012(E)/CIE S 014-3/E:2011-\n--\n-Colour stimuli with diffe...
CIE S 014-1:2006 Colorimetry - Part 1: CIE Standard Colorimetric Observers
CIE S 014-1:2006 Colorimetry - Part 1: CIE Standard Colorimetric Observers
Superseded by Colorimetry - Part 1: CIE Standard Colorimetric Observers, 2nd Edition-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 11664-1:2007(E)/CIE S 014-1/E:2006-\n--\n-This CIE Sta...
CIE S 014-5:2009 Colorimetry - Part 5: CIE 1976 L*u*v* Colour Space and u', v', Uniform Chromaticity Scale Diagram
CIE S 014-5:2009 Colorimetry - Part 5: CIE 1976 L*u*v* Colour Space and u', v', Uniform Chromaticity Scale Diagram
Superseded by Colorimetry - Part 5: CIE 1976 L*u*v* Colour Space and u', v' Uniform Chromaticity Scale Diagram, 2nd Edition-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 11664-5:2009(E)...
ISO/CIE 11664-1:2019(F) Colorim�trie ? Partie 1: Observateurs CIE de r�f�rence pour la colorim�trie
ISO/CIE 11664-1:2019(F) Colorim�trie ? Partie 1: Observateurs CIE de r�f�rence pour la colorim�trie
This document was prepared by the International Commission on Illumination (CIE) in cooperation with Technical Committee ISO/TC 274, Light and lighting. This first edition of ISO/C...
Standardization in Health and Medical Informatics
Standardization in Health and Medical Informatics
When things go well then often it is because they conform to standards (ISO, 2005). According to the Oxford Dictionary of Modern English, there is a lot of explanation of what stan...
The influence of corporate social responsibility on impulse buying
The influence of corporate social responsibility on impulse buying
PurposeCorporate social responsibility (CSR) ISO standards have been noted as an essential marketing strategy by which firms can achieve consumer trust while improving environmenta...
CIE S 003-1996 CIE Standard Overcast Sky and Clear Sky
CIE S 003-1996 CIE Standard Overcast Sky and Clear Sky
Superseded by Spatial Distribution of Daylight - CIE Standard General Sky-\n--\n-Joint ISO/CIE Standard-\n--\n-ISO 15469:2004 (E)/CIE S 011/E:2003-\n--\n-CIE has published the Stan...
CIE 009-1963 History of the CIE
CIE 009-1963 History of the CIE
Superseded by: -\n-CIE 082-1990 CIE History 1913-1988-\n--\n- -\n--\n-In 1963, the history of the first 50 years of the CIE together with the 13 years of its predecessor, the CIP, ...

