Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Is motor‐driven insertion of orthodontic miniscrews more advantageous than manual insertion? A micro‐CT evaluation of bone miniscrew contact surface area and cortical microcracks in rabbits

View through CrossRef
AbstractAimThis in vitro study aimed to evaluate and compare the bone–miniscrew contact surface area (BMC) and the cortical bone microcracks (CM) resulting from manual (hand‐driven) and automated (motor‐driven) orthodontic miniscrew (OM) insertion methods.MethodsThirty‐three OM were inserted in the femurs of nine New Zealand rabbits using manual (n = 16) and automated (n = 17) insertions. After euthanizing the rabbits, bone blocks, each including one OM, were sawed. Micro‐CT scanning was performed, and data analysis included reconstruction, binarization and quantification of morphometric parameters of BMC and the number and length of CM. Means and standard deviations for complete BMC, complete BMC proportion, cortical BMC, cortical BMC proportion, and length and number of CM were calculated. Mixed model analysis was used to adjust for more than one sample/CM per animal. A paired t‐test was used to compare the number of CM between the two groups.ResultsCompared to the automated insertion, manually inserted miniscrews had significantly lower complete BMC (7.54 ± 1.80 mm2 vs. 11.99 ± 3.64 mm2), cortical BMC (5.91 ± 1.48 mm2 vs. 8.48 ± 1.90 mm2) and cortical BMC proportion (79.44 ± 5.84% vs. 87.94 ± 3.66%). However, it was not statistically significant in complete BMC proportion (p = .052). The automated insertion also resulted in a significantly lower mean number of CM than the manual method (p = .012). However, the length of the cracks was shorter in the manual group but with no significant difference (p = 0.256).ConclusionMotor‐driven OM insertion results in superior BMC and reduction in the number of CM, which may lead to better miniscrew stability.
Title: Is motor‐driven insertion of orthodontic miniscrews more advantageous than manual insertion? A micro‐CT evaluation of bone miniscrew contact surface area and cortical microcracks in rabbits
Description:
AbstractAimThis in vitro study aimed to evaluate and compare the bone–miniscrew contact surface area (BMC) and the cortical bone microcracks (CM) resulting from manual (hand‐driven) and automated (motor‐driven) orthodontic miniscrew (OM) insertion methods.
MethodsThirty‐three OM were inserted in the femurs of nine New Zealand rabbits using manual (n = 16) and automated (n = 17) insertions.
After euthanizing the rabbits, bone blocks, each including one OM, were sawed.
Micro‐CT scanning was performed, and data analysis included reconstruction, binarization and quantification of morphometric parameters of BMC and the number and length of CM.
Means and standard deviations for complete BMC, complete BMC proportion, cortical BMC, cortical BMC proportion, and length and number of CM were calculated.
Mixed model analysis was used to adjust for more than one sample/CM per animal.
A paired t‐test was used to compare the number of CM between the two groups.
ResultsCompared to the automated insertion, manually inserted miniscrews had significantly lower complete BMC (7.
54 ± 1.
80 mm2 vs.
11.
99 ± 3.
64 mm2), cortical BMC (5.
91 ± 1.
48 mm2 vs.
8.
48 ± 1.
90 mm2) and cortical BMC proportion (79.
44 ± 5.
84% vs.
87.
94 ± 3.
66%).
However, it was not statistically significant in complete BMC proportion (p = .
052).
The automated insertion also resulted in a significantly lower mean number of CM than the manual method (p = .
012).
However, the length of the cracks was shorter in the manual group but with no significant difference (p = 0.
256).
ConclusionMotor‐driven OM insertion results in superior BMC and reduction in the number of CM, which may lead to better miniscrew stability.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 B...
Periodontal Implications of Orthodontic Treatment: Assessment of The Balance between Tooth Movement and Surrounding Tissue
Periodontal Implications of Orthodontic Treatment: Assessment of The Balance between Tooth Movement and Surrounding Tissue
Orthodontic treatment also aims to maintain ideal periodontal health. Gingival/periodontal conditions and orthodontic interventions have a complicated relationship because orthodon...
Investigation of Different Miniscrew-Supported Mesialization Protocols with Finite Element Analysis
Investigation of Different Miniscrew-Supported Mesialization Protocols with Finite Element Analysis
Background: To examine the force and stress distributions caused by two different mesialization methods in dentoalveolar structures in cases of congenital bilateral maxillary later...
The effect of housing system on the behaviour and growth parameters of fattening rabbits
The effect of housing system on the behaviour and growth parameters of fattening rabbits
AbstractThree housing systems for fattening rabbits were compared using a stocking density of 15 rabbits m–2. The rabbits were housed in large pens (3.67 m2, 50 rabbits), small pen...

Back to Top