Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device

View through CrossRef
ABSTRACT Objective: To clarify the in vivo effect of an automatic embedding device on miniscrew stability. Materials and Methods: 42 miniscrews were implanted into rabbit femurs. The miniscrews with the novel auxiliary device formed the auxiliary group (n = 11 at 4 weeks; n = 11 at 8 weeks) and the miniscrews without the auxiliary device formed the nonauxiliary control group (n = 9 at 4 weeks; n = 11 at 8 weeks). Cortical bone thickness, distance from the cortical bone surface to the miniscrew head, and implantation depth of the spike were measured using micro-computed tomography. The mechanical retention force was evaluated by measuring the displacement of the miniscrew head after it was loaded perpendicular to its long axis. In the lateral displacement test, effects of the auxiliary (with vs without auxiliary), and time (4 vs 8 weeks) were assessed using the Brunner–Langer nonparametric analysis of longitudinal data in factorial experiments. Results: The mean implantation depth of the spike in the auxiliary group at 4 and 8 weeks was 0.28 mm (median: 0.33; SD: 0.12) and 0.37 mm (median: 0.33; SD: 0.19), respectively. The retention force was approximately 2.0 to 2.8 and 1.6 to 1.8 times greater in the auxiliary group than in the nonauxiliary group at 4 and 8 weeks, respectively. Conclusions: The auxiliary device improved the mechanical retention force without the need to increase miniscrew length or diameter. This may enable the safe use of miniscrews in difficult areas.
Title: Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device
Description:
ABSTRACT Objective: To clarify the in vivo effect of an automatic embedding device on miniscrew stability.
Materials and Methods: 42 miniscrews were implanted into rabbit femurs.
The miniscrews with the novel auxiliary device formed the auxiliary group (n = 11 at 4 weeks; n = 11 at 8 weeks) and the miniscrews without the auxiliary device formed the nonauxiliary control group (n = 9 at 4 weeks; n = 11 at 8 weeks).
Cortical bone thickness, distance from the cortical bone surface to the miniscrew head, and implantation depth of the spike were measured using micro-computed tomography.
The mechanical retention force was evaluated by measuring the displacement of the miniscrew head after it was loaded perpendicular to its long axis.
In the lateral displacement test, effects of the auxiliary (with vs without auxiliary), and time (4 vs 8 weeks) were assessed using the Brunner–Langer nonparametric analysis of longitudinal data in factorial experiments.
Results: The mean implantation depth of the spike in the auxiliary group at 4 and 8 weeks was 0.
28 mm (median: 0.
33; SD: 0.
12) and 0.
37 mm (median: 0.
33; SD: 0.
19), respectively.
The retention force was approximately 2.
0 to 2.
8 and 1.
6 to 1.
8 times greater in the auxiliary group than in the nonauxiliary group at 4 and 8 weeks, respectively.
Conclusions: The auxiliary device improved the mechanical retention force without the need to increase miniscrew length or diameter.
This may enable the safe use of miniscrews in difficult areas.

Related Results

Anchorage loss and inclination during retraction: A systematic review
Anchorage loss and inclination during retraction: A systematic review
This review focused on anchorage lost and incisor inclination variation in the orthodontic retraction process. It compared the effectiveness of skeletal anchorage to that of conven...
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Abstract A cervical rib (CR), also known as a supernumerary or extra rib, is an additional rib that forms above the first rib, resulting from the overgrowth of the transverse proce...
Comparative Study Between English And Korean Interrogative Sentences
Comparative Study Between English And Korean Interrogative Sentences
This study discusses English And Korean Interrogative Sentences. It is aimed at describing the forms and types of English and Korean Interrogative Sentences and finding out the sim...
Efficiency of anchorage systems for RC beams strengthened in flexure using basalt fiber reinforced polymers
Efficiency of anchorage systems for RC beams strengthened in flexure using basalt fiber reinforced polymers
Abstract Recently, Basalt Fiber Reinforced Polymer (BFRP) composites emerged as a new FRP type, in addition to the commonly used glass, carbo...
Microscrew Anchorage in Skeletal Anterior Open-bite Treatment
Microscrew Anchorage in Skeletal Anterior Open-bite Treatment
Abstract Objective: To evaluate the effectiveness of miniscrew anchorage for intrusion of the posterior dentoalveolar region to correct skeletal open bite. ...
Comparative evaluation of anchorage loss and canine retraction rate using mini-implant anchorage versus conventional molar anchorage
Comparative evaluation of anchorage loss and canine retraction rate using mini-implant anchorage versus conventional molar anchorage
Orthodontic anchorage control during space closure is critical to prevent unwanted tooth movement, prolong treatment and maintain facial aesthetics. This randomised controlled tria...
Experimental Research on Bonded Anchorage of Carbon Fiber Reinforced Polymer Prestressed Strands
Experimental Research on Bonded Anchorage of Carbon Fiber Reinforced Polymer Prestressed Strands
Aiming at the problems of a large number of corrosion and fatigue damage of the current prestressed steel strands, this paper adopts carbon fiber-reinforced composite (CFRP) strand...

Back to Top