Javascript must be enabled to continue!
Reliability and safety of miniscrew insertion planning with the use of lateral cephalograms assessed on corresponding cone-beam computer tomography images
View through CrossRef
Abstract
Background/Objectives
Recently, lateral cephalograms have been proposed for guided miniscrew insertion planning. Therefore, the aim was to assess the reliability and safety of such planning on corresponding cone-beam computer tomography (CBCT) images.
Materials/Methods
Intraoral scans, lateral cephalograms, and CBCT images of 52 subjects (even sexes distribution), aged 15.1 ± 2.5 years, were included. Miniscrew (n = 104) insertion planning was performed using lateral cephalograms superimposed on the maxillary intraoral scans, while the assessment of their bicortical placement, length in bone, contact with adjacent teeth, incisive canal, and nasal floor perforation was done on corresponding superimposed CBCT images. Moreover, maxillary incisor inclination, crowding, and the maxillary intercanine width were measured.
Results
The overall miniscrew length in bone was 7.2 ± 1.3mm. Bicortical placement was seen in 58.7% of the sample (38.5% of subjects). Incisive canal and nasal floor perforation was seen in 25% and 21.2% of subjects, respectively. No contact of the miniscrew with adjacent teeth was recorded. A negative significant interaction was seen between the miniscrew length in bone, the percentage of total miniscrew length and maxillary anterior teeth crowding (β, −0.10, P = .047 and β, −0.90, P = .006, respectively). Moreover, a positive significant interaction was seen between the incisive canal perforation and maxillary anterior teeth crowding (OR = 1.32, P = .021).
Limitations
Exclusion of subjects with impacted teeth.
Conclusions
Miniscrew insertion planning using lateral cephalograms, despite being safe in preventing contact with adjacent teeth, is limited in achieving bicortical placement and insufficient in completely avoiding incisive canal and nasal floor perforation.
Oxford University Press (OUP)
Title: Reliability and safety of miniscrew insertion planning with the use of lateral cephalograms assessed on corresponding cone-beam computer tomography images
Description:
Abstract
Background/Objectives
Recently, lateral cephalograms have been proposed for guided miniscrew insertion planning.
Therefore, the aim was to assess the reliability and safety of such planning on corresponding cone-beam computer tomography (CBCT) images.
Materials/Methods
Intraoral scans, lateral cephalograms, and CBCT images of 52 subjects (even sexes distribution), aged 15.
1 ± 2.
5 years, were included.
Miniscrew (n = 104) insertion planning was performed using lateral cephalograms superimposed on the maxillary intraoral scans, while the assessment of their bicortical placement, length in bone, contact with adjacent teeth, incisive canal, and nasal floor perforation was done on corresponding superimposed CBCT images.
Moreover, maxillary incisor inclination, crowding, and the maxillary intercanine width were measured.
Results
The overall miniscrew length in bone was 7.
2 ± 1.
3mm.
Bicortical placement was seen in 58.
7% of the sample (38.
5% of subjects).
Incisive canal and nasal floor perforation was seen in 25% and 21.
2% of subjects, respectively.
No contact of the miniscrew with adjacent teeth was recorded.
A negative significant interaction was seen between the miniscrew length in bone, the percentage of total miniscrew length and maxillary anterior teeth crowding (β, −0.
10, P = .
047 and β, −0.
90, P = .
006, respectively).
Moreover, a positive significant interaction was seen between the incisive canal perforation and maxillary anterior teeth crowding (OR = 1.
32, P = .
021).
Limitations
Exclusion of subjects with impacted teeth.
Conclusions
Miniscrew insertion planning using lateral cephalograms, despite being safe in preventing contact with adjacent teeth, is limited in achieving bicortical placement and insufficient in completely avoiding incisive canal and nasal floor perforation.
Related Results
#1089 Outcomes of medical and surgical peritoneal dialysis catheter insertion: a single centre experience
#1089 Outcomes of medical and surgical peritoneal dialysis catheter insertion: a single centre experience
Abstract
Background and Aims
Medical insertion of peritoneal dialysis (PD) catheters has been common practice within the ...
Domination of Polynomial with Application
Domination of Polynomial with Application
In this paper, .We .initiate the study of domination. polynomial , consider G=(V,E) be a simple, finite, and directed graph without. isolated. vertex .We present a study of the Ira...
Optimizing Infrazygomatic Miniscrew Insertion Parameters: Systematic Review and Meta-Regression Analysis of Bone Thickness by Insertion Height, Angulation, and Anatomical Position
Optimizing Infrazygomatic Miniscrew Insertion Parameters: Systematic Review and Meta-Regression Analysis of Bone Thickness by Insertion Height, Angulation, and Anatomical Position
Introduction: Infrazygomatic crest (IZC) miniscrews are widely used for skeletal anchorage in orthodontics. Despite their growing popularity, the optimal insertion parameters—such ...
A CROSS-SECTIONAL STUDY OF ARTIFACTS IN CONE BEAM COMPUTED TOMOGRAPHY IMAGES OF PATIENTS IN A HOSPITAL
A CROSS-SECTIONAL STUDY OF ARTIFACTS IN CONE BEAM COMPUTED TOMOGRAPHY IMAGES OF PATIENTS IN A HOSPITAL
Introduction:In the field of dentistry, cone beam computed tomography is frequently used as a method of research. Although it provides a three-dimensional image of the head and nec...
Comparison Between Cephalometric Measurements Derived from Cone Beam Computed Tomography and Lateral Cephalogram
Comparison Between Cephalometric Measurements Derived from Cone Beam Computed Tomography and Lateral Cephalogram
Objective: To compare the mean craniofacial linear and angular measurements derived from cone beam computed tomography synthesized lateral cephalogram and those obtained from conve...
Clinical Experience and Digital Knowledge in Virtual Planning of Palatal Orthodontic Miniscrew Insertion
Clinical Experience and Digital Knowledge in Virtual Planning of Palatal Orthodontic Miniscrew Insertion
At present, temporary anchorage devices (TADs) are continuously gaining importance because of their usability and their possibility to broaden clinical force applications; however,...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Automated tooth numbering on panoramic radiographs versus cone-beam computed tomographs: A diagnostic accuracy study of a commercial artificial intelligence system
Automated tooth numbering on panoramic radiographs versus cone-beam computed tomographs: A diagnostic accuracy study of a commercial artificial intelligence system
Abstract
Objectives
To assess the diagnostic accuracy of a commercial artificial intelligence system for automated tooth ...