The Reference Wideband Inductive Current Transformer
View through CrossRef
The aim of this paper is to show that the developed inductive current transformer may ensure the required wideband transformation accuracy and it may be applied, as the reference source, in the measuring system for the evaluation of the transformation accuracy of inductive current transformers for harmonics of distorted current. This device ensures 5 A and 1 A RMS secondary currents to provide the opportunity to use the differential measuring setup. Such solutions are characterized by the significantly reduced measurement uncertainty in relation to the comparative measurements made between two current/voltage channels. The problems required to ensure the high wideband transformation accuracy, including the self-generation phenomenon of the low order higher harmonics to the secondary current and a too-low frequency range of operation, were overcome in the design process. The values of its ratio error and the phase displacement of the developed reference wideband inductive current transformer did not exceed ±0.2%/° up to 1 kHz, ±0.4%/° from 1 kHz up to 1.5 kHz and ±0.5%/° from 1.5 kHz up to 3 kHz, as is required to perform the test procedure in accordance with the optional requirements for the inductive current transformers defined in the new edition of the standard IEC 61869-1.
Title: The Reference Wideband Inductive Current Transformer
Description:
The aim of this paper is to show that the developed inductive current transformer may ensure the required wideband transformation accuracy and it may be applied, as the reference source, in the measuring system for the evaluation of the transformation accuracy of inductive current transformers for harmonics of distorted current.
This device ensures 5 A and 1 A RMS secondary currents to provide the opportunity to use the differential measuring setup.
Such solutions are characterized by the significantly reduced measurement uncertainty in relation to the comparative measurements made between two current/voltage channels.
The problems required to ensure the high wideband transformation accuracy, including the self-generation phenomenon of the low order higher harmonics to the secondary current and a too-low frequency range of operation, were overcome in the design process.
The values of its ratio error and the phase displacement of the developed reference wideband inductive current transformer did not exceed ±0.
2%/° up to 1 kHz, ±0.
4%/° from 1 kHz up to 1.
5 kHz and ±0.
5%/° from 1.
5 kHz up to 3 kHz, as is required to perform the test procedure in accordance with the optional requirements for the inductive current transformers defined in the new edition of the standard IEC 61869-1.
Related Results
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Evaluation of the Current Shunt Influence on the Determined Wideband Accuracy of Inductive Current Transformers
Evaluation of the Current Shunt Influence on the Determined Wideband Accuracy of Inductive Current Transformers
This manuscript presents performed laboratory studies and the analysis of the impact of current shunt values used in the differential connection on the wideband metrological perfor...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Why Should We Test the Wideband Transformation Accuracy of Inductive Current Transformers?
Why Should We Test the Wideband Transformation Accuracy of Inductive Current Transformers?
Inductive current transformers are characterized by different transformation accuracies for higher harmonics of distorted primary currents. Therefore, it is highly required to perf...
Analysis of Transformer Service Life Prediction at Traction Substation Cipete Raya MRT Jakarta Based on Temperature and Load Using Linear Regression Method.
Analysis of Transformer Service Life Prediction at Traction Substation Cipete Raya MRT Jakarta Based on Temperature and Load Using Linear Regression Method.
PT Mass Rapid Transit Jakarta operates a mass transportation system from Lebak Bulus Station to Bundaran HI. One of the traction substations is located in Cipete Raya, with a volta...