Javascript must be enabled to continue!
BEYOND THE PIXEL: CAN SYNTHETIC 2D MAMMOGRAPHY DELIVER WHAT DIGITAL CAN'T
View through CrossRef
Objective: This study aimed to compare two-dimensional (2D) synthetic mammography (SM) and conventional 2D
full-field digital mammography (FFDM) in the evaluation of breast lesions. We aim to determine whether SM, when
combined with digital breast tomosynthesis (DBT), can serve as a new standard suitable for clinical adoption. This potential shift could impact
existing screening protocols, offering benefits such as improved patient outcomes, maintained diagnostic accuracy, and workflow efficiency.
Implementing SM+DBT may reduce radiation exposure, streamline image acquisition, and maintain diagnostic detail. This protocol could also
increase patient throughput by minimizing image capture time and may enable more frequent, guideline-aligned screenings, ultimately
supporting healthcare delivery efficiency from a clinical perspective. Mammograms from 100 patients wi Material And Method: th suspected
breast pathologies were obtained using the Hologic Selenia Dimensions System in COMBO HD mode, generating FFDM, DBT, and SM
images. FFDM and SM images were independently assessed using the 5th edition ACR Breast Imaging Reporting and Data System (5th edition
BI-RADS) lexicon and compared. Institutional review board approval and patient consent were obtained. Spiculated margins and fine Result:
pleomorphic calcifications were more distinctly visualised on SM images. FFDM images provided a more precise visualisation of nipple
retraction and skin thickening. There was no significant difference in average glandular dose between FFDM and SM images (p = 0.12). BIRADS categorisation showed complete agreement across both methods in all cases. FFDM and SM images Conclusion: provided equivalent
diagnostic performance for breast lesion evaluation. Combining DBT with SM reduced patient radiation dose without compromising diagnostic
accuracy. Synthetic mammography may be considered a viable alternative to full-field digital mammogra Advances In Knowledge: phy when
combined with digital breast tomosynthesis.
Title: BEYOND THE PIXEL: CAN SYNTHETIC 2D MAMMOGRAPHY DELIVER WHAT DIGITAL CAN'T
Description:
Objective: This study aimed to compare two-dimensional (2D) synthetic mammography (SM) and conventional 2D
full-field digital mammography (FFDM) in the evaluation of breast lesions.
We aim to determine whether SM, when
combined with digital breast tomosynthesis (DBT), can serve as a new standard suitable for clinical adoption.
This potential shift could impact
existing screening protocols, offering benefits such as improved patient outcomes, maintained diagnostic accuracy, and workflow efficiency.
Implementing SM+DBT may reduce radiation exposure, streamline image acquisition, and maintain diagnostic detail.
This protocol could also
increase patient throughput by minimizing image capture time and may enable more frequent, guideline-aligned screenings, ultimately
supporting healthcare delivery efficiency from a clinical perspective.
Mammograms from 100 patients wi Material And Method: th suspected
breast pathologies were obtained using the Hologic Selenia Dimensions System in COMBO HD mode, generating FFDM, DBT, and SM
images.
FFDM and SM images were independently assessed using the 5th edition ACR Breast Imaging Reporting and Data System (5th edition
BI-RADS) lexicon and compared.
Institutional review board approval and patient consent were obtained.
Spiculated margins and fine Result:
pleomorphic calcifications were more distinctly visualised on SM images.
FFDM images provided a more precise visualisation of nipple
retraction and skin thickening.
There was no significant difference in average glandular dose between FFDM and SM images (p = 0.
12).
BIRADS categorisation showed complete agreement across both methods in all cases.
FFDM and SM images Conclusion: provided equivalent
diagnostic performance for breast lesion evaluation.
Combining DBT with SM reduced patient radiation dose without compromising diagnostic
accuracy.
Synthetic mammography may be considered a viable alternative to full-field digital mammogra Advances In Knowledge: phy when
combined with digital breast tomosynthesis.
Related Results
Access Denied
Access Denied
Introduction
As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Abstract IA15: Neighborhood factors and changes in mammography screening rates in response to promotora intervention in Latinas
Abstract IA15: Neighborhood factors and changes in mammography screening rates in response to promotora intervention in Latinas
Abstract
Latinas have relatively low rates of mammography screening participation, which may contribute to later stage of breast cancer at diagnosis for Latinas, and...
Cost–benefit analysis of mammography screening: the perspective of Nigerian healthcare providers
Cost–benefit analysis of mammography screening: the perspective of Nigerian healthcare providers
Introduction
There is no national breast cancer screening implemented in Nigeria. The National Cancer Control Plan (NCCP) has a goal of making screening services ...
Comparison of Chromosomal Damage caused by Conventional and Digital Mammography in Human Peripheral Lymphocytes
Comparison of Chromosomal Damage caused by Conventional and Digital Mammography in Human Peripheral Lymphocytes
ABSTRACT
Background:
Mammography is a widely used technology preferred by doctors for the early detection of breast canc...
Intervention to Improve Mammography Screening at a Student-Run Free Clinic
Intervention to Improve Mammography Screening at a Student-Run Free Clinic
Background: Most late-stage breast cancer occurs in those who have never been screened. Uninsured women have lower screening rates than insured women. Student-run free clinics (SRF...
Abstract P5-01-02: Glandular dose in contrast-enhanced dual-energy mammography
Abstract P5-01-02: Glandular dose in contrast-enhanced dual-energy mammography
Abstract
INTRODUCTION
Estimation of the Average Glandular Dose (AGD) absorbed by the breast during x-ray based examination is an established part of q...
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
THE INFLUENCE OF MICRO-INFLUENCERS AND DIGITAL MARKETING ON PURCHASE DECISIONS OF TIKTOK SHOP CUSTOMERS IN BENGKULU CITY
Andhes Tiani Putri, Meylaty F
12Faculty Of Economic
E...
Psychological predictors of intention and avoidance of attending organized mammography screening in Norway: applying the Extended Parallel Process Model
Psychological predictors of intention and avoidance of attending organized mammography screening in Norway: applying the Extended Parallel Process Model
Abstract
Background
Mammography screening is the main method for early detection of breast cancer in Norway. Few studies have focused on psychologic...

