Javascript must be enabled to continue!
Results and cost analysis of Amplatzer® Ductal Occluder-ii, Nit Occlud® Lê Coil, and Konar-MF® ventricular septal defect occluder for percutaneous ventricular septal defect closure
View through CrossRef
Background: A number of devices have been used for percutaneous closure of ventricular septal defect (VSD) in this era of Jaminan Kesehatan Nasional. The aim of this study is to describe the differences in results and cost analysis of various devices used for percutaneous closure of VSD.
Patients and methods: This retrospective study was done in 88 patients underwent transcatheter VSD closure between May 2015-April 2019 at Sanglah Hospital Indonesia (regional 2, medical service level 3). Three types of devices were compared: Amplatzer® Ductal Occluder-II (ADO-II®), Nit Occlud® Lê Coil, and KONAR-MF® VSD Occluder (MFO®). Total cost and hospital earnings from Indonesia Case Based Groups (INA-CBG’s), procedure outcomes, and complications were recorded. Statistical analysis was done using Kruskal-Wallis test and Mann-Whitney test.
Results: Successful deployment of ADO-II® Nit Occlud, ® Lê Coil, and MFO® were 33, 32, and 21 cases respectively. Procedure and fluoroscopy time were shorter in ADO-II® compared to other groups (p=0.001 and 0.003). Complication rate was equally similar in all groups. Real cost was higher in Nit Occlud® Lê Coil compared to other groups. Negative hospital earnings was smaller in ADO-II® and MFO® groups than Nit Occlud® Lê Coil group (median -1,633,850 vs -14,006,600 vs -1,247,900 respectively), adjustment for length of stay found similar result. Adjustment by admission class found no difference of hospital earnings.
Conclusion: The ADO-II® and MFO® have the smallest cost. Considering the cost-effectiveness and feasibility, ADO-II® can be chosen in small defects (<6 mm), meanwhile MFO® in larger defects. All devices described have equal success rate and complications.
Title: Results and cost analysis of Amplatzer® Ductal Occluder-ii, Nit Occlud® Lê Coil, and Konar-MF® ventricular septal defect occluder for percutaneous ventricular septal defect closure
Description:
Background: A number of devices have been used for percutaneous closure of ventricular septal defect (VSD) in this era of Jaminan Kesehatan Nasional.
The aim of this study is to describe the differences in results and cost analysis of various devices used for percutaneous closure of VSD.
Patients and methods: This retrospective study was done in 88 patients underwent transcatheter VSD closure between May 2015-April 2019 at Sanglah Hospital Indonesia (regional 2, medical service level 3).
Three types of devices were compared: Amplatzer® Ductal Occluder-II (ADO-II®), Nit Occlud® Lê Coil, and KONAR-MF® VSD Occluder (MFO®).
Total cost and hospital earnings from Indonesia Case Based Groups (INA-CBG’s), procedure outcomes, and complications were recorded.
Statistical analysis was done using Kruskal-Wallis test and Mann-Whitney test.
Results: Successful deployment of ADO-II® Nit Occlud, ® Lê Coil, and MFO® were 33, 32, and 21 cases respectively.
Procedure and fluoroscopy time were shorter in ADO-II® compared to other groups (p=0.
001 and 0.
003).
Complication rate was equally similar in all groups.
Real cost was higher in Nit Occlud® Lê Coil compared to other groups.
Negative hospital earnings was smaller in ADO-II® and MFO® groups than Nit Occlud® Lê Coil group (median -1,633,850 vs -14,006,600 vs -1,247,900 respectively), adjustment for length of stay found similar result.
Adjustment by admission class found no difference of hospital earnings.
Conclusion: The ADO-II® and MFO® have the smallest cost.
Considering the cost-effectiveness and feasibility, ADO-II® can be chosen in small defects (<6 mm), meanwhile MFO® in larger defects.
All devices described have equal success rate and complications.
Related Results
Cardiovascular Malformations Among Preterm Infants
Cardiovascular Malformations Among Preterm Infants
Objective. Preterm birth and cardiovascular malformations are the 2 most common causes of neonatal and infant death, but there are no published population-based reports on the rela...
Transcatheter and hybrid closure of muscular ventricular septal defects using the KONAR-MF™ occluder: a multicentre paediatric experience in India
Transcatheter and hybrid closure of muscular ventricular septal defects using the KONAR-MF™ occluder: a multicentre paediatric experience in India
Abstract
Background:
The KONAR-MF™ occluder, with its flexible medium-profile design, has broadened the feasibility of tr...
The clinical evaluation of transcatheter closure of perimembranous ventricular septal defects with the Amplatzer duct occluder II
The clinical evaluation of transcatheter closure of perimembranous ventricular septal defects with the Amplatzer duct occluder II
Objectives
Investigate the feasibility of perimembranous ventricular septal defects closure with the Amplatzer duct occluder II.
...
Advanced three-dimensional surgical planning of complex ventricular anatomy in transposition of the great arteries
Advanced three-dimensional surgical planning of complex ventricular anatomy in transposition of the great arteries
Abstract
This is a case of a 6-week-old male with D-TGA and multiple large ventricular septal defects who presented with oxygen desaturations into the 60s. He had initially unde...
COMPARATIVE STUDY OF TWO OCCLUDER-RELEASE TECHNIQUES IN TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECT
COMPARATIVE STUDY OF TWO OCCLUDER-RELEASE TECHNIQUES IN TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECT
Objectives
Reported experience with the retained guidewire technique in transcatheter closure of perimembranous ventricular septal defect (VSD) is limited. To com...
Clinical evaluation of capsular ventricular septal defect with multiple export underwent transcatheter closure
Clinical evaluation of capsular ventricular septal defect with multiple export underwent transcatheter closure
Objective
To evaluate the feasibility, safety and efficacy of capsular ventricular septal defect with multiple export underwent Tran catheter closure.
...
Endoscopic closure of a bronchopleural fistula after pneumonectomy with the Amplatzer occluder: a step forward?
Endoscopic closure of a bronchopleural fistula after pneumonectomy with the Amplatzer occluder: a step forward?
Abstract
OBJECTIVES
A bronchopleural fistula after pneumonectomy is a relatively rare but very serious complicat...
The Incidence of Isolated Ventricular Septal Defect in Libyan Newborns
The Incidence of Isolated Ventricular Septal Defect in Libyan Newborns
This study aimed to evaluate the incidence and spontaneous closure of ventricular septal defects in a randomly selected newborn population, using color Doppler echocardiographic sc...

