Javascript must be enabled to continue!
Perancangan dan Penempatan Alat Pemadam Kebakaran Jenis Sprinkler
View through CrossRef
The fire suppression ability of this sprinkler installation compared to other fire extinguishing equipment has been proven to be more effective. Because the sprinkler system does not require an operator when operating, fires can be prevented earlier before causing greater losses. For this reason, the implementation of sprinkler systems in buildings is crucial. According to KEPMEN PU NO. 10/KPTS/2000, a building must have elements that can maintain structural stability to a certain level during a fire. This research was conducted directly in the field, and the necessary data was obtained independently through interviews with relevant parties. The author conducted research observations in the archive warehouse to obtain both primary and secondary data. Primary data included field documentation and calculations. Planning calculations were done directly by calculating the number of sprinklers, water requirements, and reservoirs to determine the precise needs. Based on the survey, it was found that the size of the archive warehouse is 48 x 48 m, totaling 2304 m2. The maximum distance between sprinklers used was 4.6 m. Therefore, the effective distance between sprinkler heads is 193 units. The result of the calculation for the water supply for the sprinkler system obtained 34,139.77 liters, with the total overall cost for the equipment and materials used being Rp. 63,121,925.74. Based on the data and calculation results regarding the planning and design of fire protection equipment in open active spaces adhering to the NFPA-13 Standard for the Year 2019, it is expected to provide comfort and safety against the threat of fire incidents.
Fakultas Hukum, Universitas Katolik Widya Karya Malang
Title: Perancangan dan Penempatan Alat Pemadam Kebakaran Jenis Sprinkler
Description:
The fire suppression ability of this sprinkler installation compared to other fire extinguishing equipment has been proven to be more effective.
Because the sprinkler system does not require an operator when operating, fires can be prevented earlier before causing greater losses.
For this reason, the implementation of sprinkler systems in buildings is crucial.
According to KEPMEN PU NO.
10/KPTS/2000, a building must have elements that can maintain structural stability to a certain level during a fire.
This research was conducted directly in the field, and the necessary data was obtained independently through interviews with relevant parties.
The author conducted research observations in the archive warehouse to obtain both primary and secondary data.
Primary data included field documentation and calculations.
Planning calculations were done directly by calculating the number of sprinklers, water requirements, and reservoirs to determine the precise needs.
Based on the survey, it was found that the size of the archive warehouse is 48 x 48 m, totaling 2304 m2.
The maximum distance between sprinklers used was 4.
6 m.
Therefore, the effective distance between sprinkler heads is 193 units.
The result of the calculation for the water supply for the sprinkler system obtained 34,139.
77 liters, with the total overall cost for the equipment and materials used being Rp.
63,121,925.
74.
Based on the data and calculation results regarding the planning and design of fire protection equipment in open active spaces adhering to the NFPA-13 Standard for the Year 2019, it is expected to provide comfort and safety against the threat of fire incidents.
Related Results
Perancangan Markas Besar Pemadam Kebakaran di Semarang
Perancangan Markas Besar Pemadam Kebakaran di Semarang
Pemadam kebakaran (BRANDWEER) adalah orang atau pasukan yang bertugas memadamkan kebakaran, melakukan penyelamatan, dan menanggulangi musibah atau bencana alam lainya. Dinas Pemada...
SEMAR: SOSIALISASI NOMOR DARURAT PEMADAM KEBAKARAN POS CILEUNYI
SEMAR: SOSIALISASI NOMOR DARURAT PEMADAM KEBAKARAN POS CILEUNYI
Kebakaran merupakan salah satu bencana yang kerap kali terjadi di pemukiman penduduk yang dapat menyebabkan kerusakan, kerugian serta memakan korban jiwa. Dengan begitu diperlukan ...
Upaya Perawatan Alat Pemadam Api Jenis Portable Foam DI MT. KATOMAS
Upaya Perawatan Alat Pemadam Api Jenis Portable Foam DI MT. KATOMAS
When there is combustion there are three main components that cause the fire which is commonly called the Fire Triangle. The fire triangle itself consists of unified and balanced H...
Mitigasi Kebakaran melalui Masyarakat
Mitigasi Kebakaran melalui Masyarakat
Upaya dini pencegahan kebakaran telah mampu menurunkan risiko kecelakaan di lingkungan permukiman padat perkotaan. Penelitian ini bertujuanuntuk mengidentifikasi kebutuhan masyarak...
Gambaran Umum Proses yang Terjadi dalam Investigasi Kebakaran Liar)
Gambaran Umum Proses yang Terjadi dalam Investigasi Kebakaran Liar)
Investigasi kebakaran hutan secara proaktif memberikan pemahaman yang lebih baik kepada manajer kehutanan, kebakaran, dan penegak hukum tentang kecenderungan penyebab kebakaran hut...
ANALISIS VISUAL TENTANG POLA KEBAKARAN HUTAN: STUDI KASUS MENGGUNAKAN DATA INDEKS CUACA DAN AREA TERBAKAR
ANALISIS VISUAL TENTANG POLA KEBAKARAN HUTAN: STUDI KASUS MENGGUNAKAN DATA INDEKS CUACA DAN AREA TERBAKAR
Kebakaran hutan menyebabkan kerugian yang signifikan dalam bentuk kerusakan habitat, emisi gasrumah kaca, hilangnya kehidupan satwa liar, dan bahkan hilangnya nyawa manusia. Untuk ...
ANALISIS PELAKSANAAN SISTEM TANGGAP DARURAT BENCANA KEBAKARAN DI RSUD ARIFIN ACHMAD PROVINSI RIAU
ANALISIS PELAKSANAAN SISTEM TANGGAP DARURAT BENCANA KEBAKARAN DI RSUD ARIFIN ACHMAD PROVINSI RIAU
Tingginya risiko kebakaran di rumah sakit, pemerintah dalam Peraturan Menteri Kesehatan Republik Indonesia Nomor 66 Tahun 2016 tentang Keselamatan dan Kesehatan Kerja Rumah Sakit (...
Construction and Validation of Sprinkler Pattern Radius Computational Model
Construction and Validation of Sprinkler Pattern Radius Computational Model
Abstract
In ascertaining the sprinkler and micro-sprinkler computational approach. computing models of sprinkler pattern radius were generated in accordance with hydraulic ...

