Javascript must be enabled to continue!
EXPERIMENTAL AND ANALYTICAL ANALYSIS OF PRE-STRESSED CONCRETE SPLICED GIRDER MODELS
View through CrossRef
The present research is concerned with experimental and analytical studies of prestressed concrete spliced and non-spliced girder models. The test groups consisted of (16) girders of rectangular sections. Eight girders are spliced while the other eight are reference non - spliced girders. Each spliced girder is composed of three concrete segments connected by splices of ordinary reinforced concrete with hooked dowels different locations. The tested girders were of single span or continuous over intermediate supports. For single span girders two splices were used and post-tensioning was carried out for the full assembled girder. For the continuous girders pre-tensioned segments were connected by splices at quarter spans.Concentrated or uniformly distributed loads have been applied to the girders. The deflection was measured at mid-spans while the strain was measured at splice zones and at mid-spans.Nonlinear analysis of the girders was carried out using a modified computer program. A comparison among the experimental and the analytical results for spliced and non-spliced girders was carried out to study the effects of splicing for different girders. Results have shown that at about 50% of the ultimate load which is approximately corresponds to the serviceability limit state, the deflection of the spliced girders is greater than that of the reference non-spliced girders in the range of (10%-15%) and the ultimate loads for the nonspliced girders are greater than those of the spliced girders in the range of (12%-17%). The difference in deflection between the Finite Element and the experimental results at 50% ofthe ultimate load was in the range of (8%-12%). Moreover, the difference in the ultimate load between the Finite Element and the experimental results was in the range of (5%-11%).
Title: EXPERIMENTAL AND ANALYTICAL ANALYSIS OF PRE-STRESSED CONCRETE SPLICED GIRDER MODELS
Description:
The present research is concerned with experimental and analytical studies of prestressed concrete spliced and non-spliced girder models.
The test groups consisted of (16) girders of rectangular sections.
Eight girders are spliced while the other eight are reference non - spliced girders.
Each spliced girder is composed of three concrete segments connected by splices of ordinary reinforced concrete with hooked dowels different locations.
The tested girders were of single span or continuous over intermediate supports.
For single span girders two splices were used and post-tensioning was carried out for the full assembled girder.
For the continuous girders pre-tensioned segments were connected by splices at quarter spans.
Concentrated or uniformly distributed loads have been applied to the girders.
The deflection was measured at mid-spans while the strain was measured at splice zones and at mid-spans.
Nonlinear analysis of the girders was carried out using a modified computer program.
A comparison among the experimental and the analytical results for spliced and non-spliced girders was carried out to study the effects of splicing for different girders.
Results have shown that at about 50% of the ultimate load which is approximately corresponds to the serviceability limit state, the deflection of the spliced girders is greater than that of the reference non-spliced girders in the range of (10%-15%) and the ultimate loads for the nonspliced girders are greater than those of the spliced girders in the range of (12%-17%).
The difference in deflection between the Finite Element and the experimental results at 50% ofthe ultimate load was in the range of (8%-12%).
Moreover, the difference in the ultimate load between the Finite Element and the experimental results was in the range of (5%-11%).
Related Results
Proyek Pembangunan Jembatan Rumah Susun Padat Karya “Pengamatan Pelaksanaan Pekerjaan Plat pada Jembatan Rumah Susun Padat Karya”
Proyek Pembangunan Jembatan Rumah Susun Padat Karya “Pengamatan Pelaksanaan Pekerjaan Plat pada Jembatan Rumah Susun Padat Karya”
Penelitian ini bertujuan untuk mengetahui faktor pertimbangan pemilihan metode erection girder, metode yang efektif untuk pelaksanaan erection girder, faktor yang mempengaruhi pros...
Load Distribution Factors in Straight and Skew Concrete I-Girder Bridges
Load Distribution Factors in Straight and Skew Concrete I-Girder Bridges
<p>Skew bridges in modern highways have become increasingly popular for economic and aesthetic considerations. The current Canadian Highway Bridge Design Code (CHBDC) specifi...
Load Distribution Factors in Straight and Skew Concrete I-Girder Bridges
Load Distribution Factors in Straight and Skew Concrete I-Girder Bridges
<p>Skew bridges in modern highways have become increasingly popular for economic and aesthetic considerations. The current Canadian Highway Bridge Design Code (CHBDC) specifi...
Study on the effect of seawater on making and curing of unreinforced concrete applications
Study on the effect of seawater on making and curing of unreinforced concrete applications
Concrete, an essential component of worldwide infrastructure, depends significantly on fresh water for its manufacturing, contributing to freshwater scarcity in many regions. As co...
Numerical Analysis on Sliding-Type Transverse Splicing Connection Applied in Widening Continuous Concrete Box-Girder Bridge
Numerical Analysis on Sliding-Type Transverse Splicing Connection Applied in Widening Continuous Concrete Box-Girder Bridge
When traditional joint structures are used to widen multi-span continuous concrete box girder bridges, excessive lateral deformation often occurs at the girder ends, typically lead...
Analysis of a Substructure Part of Metro Structure as Per Live Data Using Analysis Tool
Analysis of a Substructure Part of Metro Structure as Per Live Data Using Analysis Tool
A metro system is a railway transport system in an urban area with a high capacity, frequency and the grade separation from other traffic. The Metro System is used in cities, agglo...
Lubricating Effects Against Interfaces Shear Strength Of Soil–Concrete And Concrete–Concrete
Lubricating Effects Against Interfaces Shear Strength Of Soil–Concrete And Concrete–Concrete
Box Jacking is a trenchless method of underpass construction that consists in pushing one or more prefabricated concrete boxes into the soil using high capacity hydraulic jacks, wh...
DESIGN OF PONDOK NONGKO BRIDGE BANYUWANGI USING BOX GIRDER
DESIGN OF PONDOK NONGKO BRIDGE BANYUWANGI USING BOX GIRDER
Pondok Nongko bridge is a bridge that connects between Sukojati and Pondok Nongko villages in Kabat district Banyuwangi regency. This research aims to design the Pondok Nongko brid...

