Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

3D range-modulators for proton therapy: near field simulations with FLUKA and comparison with film measurements

View through CrossRef
Abstract The 3D range-modulator is a device used in particle delivery systems that can create a highly conformal and homogeneous dose distribution in the target volume with mono-energetic beams, providing an option for high dose-rate FLASH therapy. In the normal case, the modulators are positioned at a typical distance of 30-50 cm in front of the target in order to avoid the fluence ripples resulting from the periodic structure of the modulators. FLUKA Monte Carlo simulation package was used to investigate the fluence distributions of protons penetrating through the 2D range-modulator, the simplified version of the 3D range-modulator, and to determine the minimum distance at which the fluence is homogeneous enough for the treatment. To implement the complex geometry of the modulator in FLUKA, a dedicated FLUKA user routine was developed for the simulation of the periodic pin structures. The highest fluence ripple occurred at a few centimetres behind the modulators and then faded away as the distance increased, which can be described by the edge-scattering effect and later by the blur-out of the overlapping contributions from the pins. Moreover, the dose distribution in water was investigated, particularly for small distances between the modulators and the water phantom. Furthermore, the Monte Carlo results were compared with radiochromic film measurements irradiated with a 3D-printed range modulator and showed a good qualitative agreement. Prospectively, for low modulator-to-target distances, the strong dose inhomogeneities which appear in the proximal part of the target, could introduce additionally a kind of ‘mini beam’ normal-tissue sparing by the 3D range-modulators.
Title: 3D range-modulators for proton therapy: near field simulations with FLUKA and comparison with film measurements
Description:
Abstract The 3D range-modulator is a device used in particle delivery systems that can create a highly conformal and homogeneous dose distribution in the target volume with mono-energetic beams, providing an option for high dose-rate FLASH therapy.
In the normal case, the modulators are positioned at a typical distance of 30-50 cm in front of the target in order to avoid the fluence ripples resulting from the periodic structure of the modulators.
FLUKA Monte Carlo simulation package was used to investigate the fluence distributions of protons penetrating through the 2D range-modulator, the simplified version of the 3D range-modulator, and to determine the minimum distance at which the fluence is homogeneous enough for the treatment.
To implement the complex geometry of the modulator in FLUKA, a dedicated FLUKA user routine was developed for the simulation of the periodic pin structures.
The highest fluence ripple occurred at a few centimetres behind the modulators and then faded away as the distance increased, which can be described by the edge-scattering effect and later by the blur-out of the overlapping contributions from the pins.
Moreover, the dose distribution in water was investigated, particularly for small distances between the modulators and the water phantom.
Furthermore, the Monte Carlo results were compared with radiochromic film measurements irradiated with a 3D-printed range modulator and showed a good qualitative agreement.
Prospectively, for low modulator-to-target distances, the strong dose inhomogeneities which appear in the proximal part of the target, could introduce additionally a kind of ‘mini beam’ normal-tissue sparing by the 3D range-modulators.

Related Results

Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
It was always based on a teenage love story between the two kids. One is a sniffer and one is not. It was designed for Central Australia because we do write these kids off there. N...
New Capabilities of the FLUKA Multi-Purpose Code
New Capabilities of the FLUKA Multi-Purpose Code
FLUKA is a general purpose Monte Carlo code able to describe the transport and interaction of any particle and nucleus type in complex geometries over an energy range extending fro...
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
Evaluation and assessment of the near field behind 3D printed-modulators for proton beam therapy
Evaluation and assessment of the near field behind 3D printed-modulators for proton beam therapy
A 3D-printed modulator is an innovation developed for particle therapy delivery systems that enables a highly conformal and homogeneous dose distribution around the tumor within a ...
Latest FLUKA developments
Latest FLUKA developments
The FLUKA Monte Carlo code has recently undergone significant enhancements, driven by needs from its user community. Key improvements are discussed, such as a new point-wise treatm...
Computer simulation of an excess proton in aqueous systems
Computer simulation of an excess proton in aqueous systems
This thesis aims at studying the microscopic physical-chemical properties of an excess proton in aqueous systems. From bulk water environments to narrow hydrophobic channels constr...
Simulation of proton and photon depth dose distributions using FLUKA and PHIT
Simulation of proton and photon depth dose distributions using FLUKA and PHIT
The most popular radiation therapy currently used for cancer treatment is photon radiation. Nevertheless, there is damage to normal tissue resulting from photon energy deposition. ...
Study on Dosimetry Technology of Absorbed Dose to Water for Proton
Study on Dosimetry Technology of Absorbed Dose to Water for Proton
In proton therapy, precise energy transfer to tissues is crucial for cancer treatment, as accurate dose delivery directly influences tumor control efficiency and minimizes radiatio...

Back to Top