Javascript must be enabled to continue!
Development and verification of an electron Monte Carlo engine for applications in intraoperative radiation therapy
View through CrossRef
AbstractBackgroundIn preparation of future clinical trials employing the Mobetron electron linear accelerator to deliver FLASH Intraoperative Radiation Therapy (IORT), the development of a Monte Carlo (MC)‐based framework for dose calculation was required.PurposeTo extend and validate the in‐house developed fast MC dose engine MonteRay (MR) for future clinical applications in IORT.MethodsMR is a CPU MC dose calculation engine written in C++ that is capable of simulating therapeutic proton, helium, and carbon ion beams. In this work, development steps are taken to include electrons and photons in MR are presented. To assess MRs accuracy, MR generated simulation results were compared against FLUKA predictions in water, in presence of heterogeneities as well as in an anthropomorphic phantom. Additionally, dosimetric data has been acquired to evaluate MRs accuracy in predicting dose‐distributions generated by the Mobetron accelerator. Runtimes of MR were evaluated against those of the general‐purpose MC code FLUKA on standard benchmark problems.ResultsMR generated dose distributions for electron beams incident on a water phantom match corresponding FLUKA calculated distributions within 2.3% with range values matching within 0.01 mm. In terms of dosimetric validation, differences between MR calculated and measured dose values were below 3% for almost all investigated positions within the water phantom. Gamma passing rate (1%/1 mm) for the scenarios with inhomogeneities and gamma passing rate (3%/2 mm) with the anthropomorphic phantom, were > 99.8% and 99.4%, respectively. The average dose differences between MR (FLUKA) and the measurements was 1.26% (1.09%). Deviations between MR and FLUKA were well within 1.5% for all investigated depths and 0.6% on average. In terms of runtime, MR achieved a speedup against reference FLUKA simulations of about 13 for 10 MeV electrons.ConclusionsValidations against general purpose MC code FLUKA predictions and experimental dosimetric data have proven the validity of the physical models implemented in MR for IORT applications. Extending the work presented here, MR will be interfaced with external biophysical models to allow accurate FLASH biological dose predictions in IORT.
Title: Development and verification of an electron Monte Carlo engine for applications in intraoperative radiation therapy
Description:
AbstractBackgroundIn preparation of future clinical trials employing the Mobetron electron linear accelerator to deliver FLASH Intraoperative Radiation Therapy (IORT), the development of a Monte Carlo (MC)‐based framework for dose calculation was required.
PurposeTo extend and validate the in‐house developed fast MC dose engine MonteRay (MR) for future clinical applications in IORT.
MethodsMR is a CPU MC dose calculation engine written in C++ that is capable of simulating therapeutic proton, helium, and carbon ion beams.
In this work, development steps are taken to include electrons and photons in MR are presented.
To assess MRs accuracy, MR generated simulation results were compared against FLUKA predictions in water, in presence of heterogeneities as well as in an anthropomorphic phantom.
Additionally, dosimetric data has been acquired to evaluate MRs accuracy in predicting dose‐distributions generated by the Mobetron accelerator.
Runtimes of MR were evaluated against those of the general‐purpose MC code FLUKA on standard benchmark problems.
ResultsMR generated dose distributions for electron beams incident on a water phantom match corresponding FLUKA calculated distributions within 2.
3% with range values matching within 0.
01 mm.
In terms of dosimetric validation, differences between MR calculated and measured dose values were below 3% for almost all investigated positions within the water phantom.
Gamma passing rate (1%/1 mm) for the scenarios with inhomogeneities and gamma passing rate (3%/2 mm) with the anthropomorphic phantom, were > 99.
8% and 99.
4%, respectively.
The average dose differences between MR (FLUKA) and the measurements was 1.
26% (1.
09%).
Deviations between MR and FLUKA were well within 1.
5% for all investigated depths and 0.
6% on average.
In terms of runtime, MR achieved a speedup against reference FLUKA simulations of about 13 for 10 MeV electrons.
ConclusionsValidations against general purpose MC code FLUKA predictions and experimental dosimetric data have proven the validity of the physical models implemented in MR for IORT applications.
Extending the work presented here, MR will be interfaced with external biophysical models to allow accurate FLASH biological dose predictions in IORT.
Related Results
Monte-Carlo Simulation mit Risk Kit (Monte-Carlo Simulation with Risk Kit)
Monte-Carlo Simulation mit Risk Kit (Monte-Carlo Simulation with Risk Kit)
<b>German Abstract:</b> Monte-Carlo Simulationen spielen eine immer bedeutender werdende Rolle der Finanzwirtschaft, den Sozialwissenschaften und im Risk Management. Mo...
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
For discretely observed barrier options, there exists no closed solution under the Black-Scholes model. Thus, it is often helpful to use Monte Carlo simulations, which are easily a...
Analisis Harga Opsi Beli Tipe Eropa dengan Metode Antithetic Variate dari Monte Carlo
Analisis Harga Opsi Beli Tipe Eropa dengan Metode Antithetic Variate dari Monte Carlo
Stock options is one of the derivative products of stocks. The purpose of this study is to analyze the price of European type call options using the antithetic variate method from ...
Research on Multi-Group Monte Carlo Calculations Based on Group Constants Generated by RMC
Research on Multi-Group Monte Carlo Calculations Based on Group Constants Generated by RMC
Abstract
Nowadays, deterministic two-step or Monte Carlo methods are commonly used in core physics calculations. However, with the development of reactor core design, tradi...
Verification of High Speed on Chip with VIP using System Verilog
Verification of High Speed on Chip with VIP using System Verilog
Abstract - The exploration work is addressing verification of High speed on chips protocol; we've used the system Verilog grounded test bench structure. I developed a system Verilo...
Overview Of Existing Engine System For Rail Application
Overview Of Existing Engine System For Rail Application
The engine is the heart of any hardware which may relate to various applications like Vehicles, Railway, etc. The rail application is the application where the engine will work as ...
Evaluating View Factors Using a Hybrid Monte-Carlo Method
Evaluating View Factors Using a Hybrid Monte-Carlo Method
AbstractThis paper demonstrates that the well-known method for calculating view factors, the Monte Carlo method, combined with ray tracing is not necessarily the most efficient str...
Monte Carlo and quasi-Monte Carlo methods
Monte Carlo and quasi-Monte Carlo methods
Monte Carlo is one of the most versatile and widely used numerical methods. Its convergence rate,
O
(
N
...