Javascript must be enabled to continue!
Signal processing techniques for operator independent Doppler ultrasound : potential for use in transcranial Doppler ultrasound
View through CrossRef
2D Doppler ultrasound can be used for continuous monitoring of vasospasm. However, the use of Doppler ultrasound suffers from operator dependence requiring a skilled ultrasonographer to make Doppler angle corrections. The aim of the research is to minimize the need of dedicated ultrasonographers for Doppler ultrasound monitoring of cerebral vasospasms. In this thesis, three studies including a steady flow phantom, pulsatile flow phantom and in vivo human internal carotid artery (ICA) were completed with the use of 3D Doppler ultrasound. The 3D vascular structure of the phantom and ICA were obtained using binary skeletonization from 3D power Doppler images. The vascular structure was used in combination with angle independent pulsed-wave Doppler to reconstruct the temporal blood velocity profiles at various parts of the vasculature. The results indicate that Doppler angle corrections can be minimized with the use of 3D Doppler ultrasound, and operator independent monitoring of blood flow is possible.
Title: Signal processing techniques for operator independent Doppler ultrasound : potential for use in transcranial Doppler ultrasound
Description:
2D Doppler ultrasound can be used for continuous monitoring of vasospasm.
However, the use of Doppler ultrasound suffers from operator dependence requiring a skilled ultrasonographer to make Doppler angle corrections.
The aim of the research is to minimize the need of dedicated ultrasonographers for Doppler ultrasound monitoring of cerebral vasospasms.
In this thesis, three studies including a steady flow phantom, pulsatile flow phantom and in vivo human internal carotid artery (ICA) were completed with the use of 3D Doppler ultrasound.
The 3D vascular structure of the phantom and ICA were obtained using binary skeletonization from 3D power Doppler images.
The vascular structure was used in combination with angle independent pulsed-wave Doppler to reconstruct the temporal blood velocity profiles at various parts of the vasculature.
The results indicate that Doppler angle corrections can be minimized with the use of 3D Doppler ultrasound, and operator independent monitoring of blood flow is possible.
Related Results
Perancangan Beban Kerja Proses Produksi Pabrik Tahu Ciburial dengan Metode Work Load Analysis
Perancangan Beban Kerja Proses Produksi Pabrik Tahu Ciburial dengan Metode Work Load Analysis
Abstract. Excessive workload can create an uncomfortable working atmosphere for workers because it can trigger the emergence of work stress more quickly. On the other hand, a lack ...
Signal processing techniques for operator independent Doppler ultrasound : potential for use in transcranial Doppler ultrasound
Signal processing techniques for operator independent Doppler ultrasound : potential for use in transcranial Doppler ultrasound
2D Doppler ultrasound can be used for continuous monitoring of vasospasm. However, the use of Doppler ultrasound suffers from operator dependence requiring a skilled ultrasonograph...
To Doppler or Not to Doppler: From Doppler Ultrasound to Color Doppler to Doppler in 3D and Beyond
To Doppler or Not to Doppler: From Doppler Ultrasound to Color Doppler to Doppler in 3D and Beyond
ABSTRACT
This review aims to provide the reader with an update on the present and potential clinical applications in Doppler ultrasound in perinatal medicine. Umbilical artery Dopp...
Transcranial electrostimulation and magnetic stimulation: modern physiotherapy technologies
Transcranial electrostimulation and magnetic stimulation: modern physiotherapy technologies
The article presents a comprehensive literature review of two non-invasive neuromodulation methods: transcranial electrical stimulation and transcranial magnetic stimulation. The a...
Long-term analgesic effect of trans-spinal direct current stimulation compared to non-invasive motor cortex stimulation in complex regional pain syndrome
Long-term analgesic effect of trans-spinal direct current stimulation compared to non-invasive motor cortex stimulation in complex regional pain syndrome
Abstract
The aim of the present study was to compare the analgesic effect of motor cortex stimulation using high-frequency repetitive transcranial magnetic stimulati...
The second four-electron singlet in the Hubbard impurity model
The second four-electron singlet in the Hubbard impurity model
We consider the energy operator of four-electron systems in the Hubbard impurity model and investigate the structure of the essential spectrum and discrete spectra for the second s...
Minimasi Risiko Muskuloskeletal Disorders dan Beban Kerja Fisik pada Operator Proses Setting Di PT. Jaya Beton Indonesia
Minimasi Risiko Muskuloskeletal Disorders dan Beban Kerja Fisik pada Operator Proses Setting Di PT. Jaya Beton Indonesia
Intisari—Penelitian ini dilakukan pada PT.Jaya Beton Indonesia dimana ditemukannya indikasi beban kerja fisik yang berlebih dan postur kerja yang buruk pada operator proses setting...
Power and Color Doppler Ultrasound Settings for Inflammatory Flow: Impact on Scoring of Disease Activity in Patients With Rheumatoid Arthritis
Power and Color Doppler Ultrasound Settings for Inflammatory Flow: Impact on Scoring of Disease Activity in Patients With Rheumatoid Arthritis
ObjectiveTo determine how settings for power and color Doppler ultrasound sensitivity vary on different high‐ and intermediate‐range ultrasound machines and to evaluate the impact ...

