Javascript must be enabled to continue!
Efficacy of urine reagent strips for analysis of cerebrospinal fluid cellularity and biochemical parameters
View through CrossRef
Background: Meningitis is a severe infection affecting the central nervous system requiring early management to prevent debilitating consequences and death. Detection of meningitis can be done by the analysis of cerebrospinal fluid cellularity and biochemistry (glucose and protein concentration). Urine reagent strips can be used to assess these variables and reach to the diagnosis of meningitis early, thereby, reducing the delay in the initiation of its treatment.
Aims and Objectives: The current study aimed to determine the efficacy of urine reagent strips for the analysis of CSF.
Materials and Methods: The current prospective study was done in a tertiary care center in Rewa, M.P., on 100 cerebral spinal fluid (CSF) samples obtained from the children suspected of meningitis, which were, then, analyzed by both the conventional methods of CSF analysis (including routine biochemical and microscopic analysis) the index test, utilizing the Combur-10 urine reagent strips for the estimation of CSF cell, protein, and glucose. These results were, then, correlated to calculate the diagnostic utility of urine reagent strips for the rapid diagnosis of meningitis.
Results: The sensitivity, specificity, and diagnostic accuracy of urine reagent strips for the detection of cell count >10/cumm were 81.81%, 98.21%, and 91%, respectively, and 78.57%, 81.25%, and 79% for detection of protein >30 mg/dL. Reagent strips showed a sensitivity and specificity of 96.85% and 79.41% for the detection of glucose levels <50 mg/dL. The two methods showed an almost perfect degree of agreement for the detection of leucocytes with Cohen’s kappa value of 0.86.
Conclusion: Reagent strips can be a helpful bedside screening test for the detection of meningitis and also in resource-limited settings.
Pharmamedix India Publication Pvt Ltd
Title: Efficacy of urine reagent strips for analysis of cerebrospinal fluid cellularity and biochemical parameters
Description:
Background: Meningitis is a severe infection affecting the central nervous system requiring early management to prevent debilitating consequences and death.
Detection of meningitis can be done by the analysis of cerebrospinal fluid cellularity and biochemistry (glucose and protein concentration).
Urine reagent strips can be used to assess these variables and reach to the diagnosis of meningitis early, thereby, reducing the delay in the initiation of its treatment.
Aims and Objectives: The current study aimed to determine the efficacy of urine reagent strips for the analysis of CSF.
Materials and Methods: The current prospective study was done in a tertiary care center in Rewa, M.
P.
, on 100 cerebral spinal fluid (CSF) samples obtained from the children suspected of meningitis, which were, then, analyzed by both the conventional methods of CSF analysis (including routine biochemical and microscopic analysis) the index test, utilizing the Combur-10 urine reagent strips for the estimation of CSF cell, protein, and glucose.
These results were, then, correlated to calculate the diagnostic utility of urine reagent strips for the rapid diagnosis of meningitis.
Results: The sensitivity, specificity, and diagnostic accuracy of urine reagent strips for the detection of cell count >10/cumm were 81.
81%, 98.
21%, and 91%, respectively, and 78.
57%, 81.
25%, and 79% for detection of protein >30 mg/dL.
Reagent strips showed a sensitivity and specificity of 96.
85% and 79.
41% for the detection of glucose levels <50 mg/dL.
The two methods showed an almost perfect degree of agreement for the detection of leucocytes with Cohen’s kappa value of 0.
86.
Conclusion: Reagent strips can be a helpful bedside screening test for the detection of meningitis and also in resource-limited settings.
Related Results
Efficacy of urine reagent strips for analysis of cerebrospinal fluid cellularity and biochemical parameters
Efficacy of urine reagent strips for analysis of cerebrospinal fluid cellularity and biochemical parameters
Background: Meningitis is a severe infection affecting the central nervous system requiring early management to prevent debilitating consequences and death. Detection of meningitis...
The Effectiveness of Longitudinal Rumble Strips on Indiana Roads
The Effectiveness of Longitudinal Rumble Strips on Indiana Roads
Rumble strips are designed and deployed to reduce run-off-road and head-on crashes by alerting drivers about near-lane departures. Although they have been widely used, their operat...
PO-258 Women's Freestyle Wrestling Athletes Prepare for Urine Ten Evaluation Before the National Games
PO-258 Women's Freestyle Wrestling Athletes Prepare for Urine Ten Evaluation Before the National Games
Objective Urine routines inspection was used as a kind of non invasive test method, which was used widely in the biochemical monitoring of athletes.The urine routine was monitored ...
Experimental Investigation of Permeability and Fluid Loss Properties of Water Based Mud Under High Pressure-High Temperature Conditions
Experimental Investigation of Permeability and Fluid Loss Properties of Water Based Mud Under High Pressure-High Temperature Conditions
Drilling in deeper formations and in high pressure and high temperature (HPHT) environments is a new frontier for the oil industry. Fifty years ago, no one would have imagined dril...
Economic comparison of methods of wound closure: wound closure strips versus sutures and wound adhesives
Economic comparison of methods of wound closure: wound closure strips versus sutures and wound adhesives
Comparaison économique des méthodes de fermeture des plaies: fermetures des plaies par sutures adhésives strips versus sutures et tissus adhésifsNotre objectif était de faire la re...
Chiral Sensitivity of Medetomidine Lateral Flow Immunoassay Test Strips
Chiral Sensitivity of Medetomidine Lateral Flow Immunoassay Test Strips
Abstract
Medetomidine has recently emerged in the illicit drug supply in the United States, and lateral flow immunoassay test strips are an inexpensive and easy-to-...
Correlation of Random Urine Protein Creatinine (P-C) Ratio with 24-Hour Protein Urine in Lupus Nephritis Patients
Correlation of Random Urine Protein Creatinine (P-C) Ratio with 24-Hour Protein Urine in Lupus Nephritis Patients
Background : Systemic lupus erythematosus (SLE) is a systemic autoimmune disease involving multiple organs including kidney and known as lupus nephritis (LN). Lupus nephritis has a...
Translational potential of synaptic alterations in Alzheimer’s disease patients and amyloid precursor protein knock-in mice
Translational potential of synaptic alterations in Alzheimer’s disease patients and amyloid precursor protein knock-in mice
AbstractSynaptic dysfunction is an early event in Alzheimer’s disease. Post-mortem studies suggest that alterations in synaptic proteins are associated with cognitive decline in Al...

