Javascript must be enabled to continue!
Stratospheric water vapour as tracer for vortex filamentation in the Arctic winter 2002/2003
View through CrossRef
Abstract. During winter 2002/2003, three balloon-borne frost point hygrometers measured high-resolution profiles of stratospheric water vapour above Ny-Ålesund, Spitsbergen. All measurements reveal a high H2O mixing ratio of about 7 ppmv above 24 km, thus differing significantly from the 5 ppmv that are commonly assumed for the calculation of polar stratospheric cloud existence temperatures. The profiles obtained on 12 December 2002 and on 17 January 2003 provide an insight into the vertical distribution of water vapour in the core of the polar vortex. Unlike the earlier profiles, the water vapour sounding on 11 February 2003 detected the vortex edge region in the lower part of the stratosphere. Here, a striking diminuition in H2O mixing ratio stands out between 16 and 19 km. The according stratospheric temperatures clarify that this dehydration can not be caused by the presence of polar stratospheric clouds or earlier PSC particle sedimentation. On the same day, ozone observations by lidar indicate a large scale movement of the polar vortex, while an ozone sonde measurement even shows laminae in the same altitude range as in the water vapour profile. Tracer lamination in the vortex edge region is caused by filamentation of the vortex. The link between the observed water vapour diminuition and filaments in the vortex edge region is highlighted by results of the MIMOSA contour advection model. In the altitude of interest, adjoined filaments of polar and mid-latitudinal air can be identified above the Spitsbergen region. A vertical cross-section reveals that the water vapour sonde has flown through polar air in the lowest part of the stratosphere. Where the low water vapour mixing ratio was detected, the balloon passed through air from a mid-latitudinal filament from about 425 to 445 K, before it finally entered the polar vortex above 450 K. The MIMOSA model results elucidate the correlation that on 11 February 2003 the frost point hygrometer measured strongly variable water vapour concentrations as the sonde detected air with different origins, respectively. Instead of being linked to dehydration due to PSC particle sedimentation, the local diminuition in the stratospheric water vapour profile of 11 February 2003 has been found to be caused by dynamical processes in the polar stratosphere.
Title: Stratospheric water vapour as tracer for vortex filamentation in the Arctic winter 2002/2003
Description:
Abstract.
During winter 2002/2003, three balloon-borne frost point hygrometers measured high-resolution profiles of stratospheric water vapour above Ny-Ålesund, Spitsbergen.
All measurements reveal a high H2O mixing ratio of about 7 ppmv above 24 km, thus differing significantly from the 5 ppmv that are commonly assumed for the calculation of polar stratospheric cloud existence temperatures.
The profiles obtained on 12 December 2002 and on 17 January 2003 provide an insight into the vertical distribution of water vapour in the core of the polar vortex.
Unlike the earlier profiles, the water vapour sounding on 11 February 2003 detected the vortex edge region in the lower part of the stratosphere.
Here, a striking diminuition in H2O mixing ratio stands out between 16 and 19 km.
The according stratospheric temperatures clarify that this dehydration can not be caused by the presence of polar stratospheric clouds or earlier PSC particle sedimentation.
On the same day, ozone observations by lidar indicate a large scale movement of the polar vortex, while an ozone sonde measurement even shows laminae in the same altitude range as in the water vapour profile.
Tracer lamination in the vortex edge region is caused by filamentation of the vortex.
The link between the observed water vapour diminuition and filaments in the vortex edge region is highlighted by results of the MIMOSA contour advection model.
In the altitude of interest, adjoined filaments of polar and mid-latitudinal air can be identified above the Spitsbergen region.
A vertical cross-section reveals that the water vapour sonde has flown through polar air in the lowest part of the stratosphere.
Where the low water vapour mixing ratio was detected, the balloon passed through air from a mid-latitudinal filament from about 425 to 445 K, before it finally entered the polar vortex above 450 K.
The MIMOSA model results elucidate the correlation that on 11 February 2003 the frost point hygrometer measured strongly variable water vapour concentrations as the sonde detected air with different origins, respectively.
Instead of being linked to dehydration due to PSC particle sedimentation, the local diminuition in the stratospheric water vapour profile of 11 February 2003 has been found to be caused by dynamical processes in the polar stratosphere.
Related Results
Stability and dynamics of geophysical neutral vortices
Stability and dynamics of geophysical neutral vortices
(English) Mesoscale and submesoscale vortical structures are ubiquitous in the ocean and atmosphere. Most of these vortices are long-lived with a lifetime of several months. They o...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract
The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Quantifying Arctic Storm Risk in a Changing Climate
Quantifying Arctic Storm Risk in a Changing Climate
<p>The Arctic has undergone significant change over the past few decades, and there has been great reductions in Arctic sea ice extent. The Arctic ocean has become mo...
Satellite observations of cirrus clouds in the lower stratosphere
Satellite observations of cirrus clouds in the lower stratosphere
<div>
<p>While cirrus cloud are frequently observed by ground-based lidars in the lowermost stratosphere, evidence from satellite observations is less c...
Water vapour monitoring with E-band microwave links of cellular backhaul
Water vapour monitoring with E-band microwave links of cellular backhaul
<p>Water vapour observations represent an important input e.g. for predicting mesoscale initiation of convective precipitation or estimating evapotranspiration. E-ban...
Dynamics of femtosecond synthesized coronary profile laser beam filamentation in air
Dynamics of femtosecond synthesized coronary profile laser beam filamentation in air
Abstract
Multiple filamentation in air of high-power ultrashort laser radiation with a transverse intensity profile resembling a corona composed of several annula...
Solar Backscatter Ultraviolet (BUV) retrievals of mid-stratospheric aerosols from the 2022 Hunga Eruption
Solar Backscatter Ultraviolet (BUV) retrievals of mid-stratospheric aerosols from the 2022 Hunga Eruption
Abstract. On 15 January 2022, a highly explosive eruption of the submarine Hunga volcano (Kingdom of Tonga) generated the largest stratospheric hydration event ever observed and th...
Investigation of the Ozone Enhancement during the 2019 Sudden Stratospheric Warming in the Southern Hemisphere
Investigation of the Ozone Enhancement during the 2019 Sudden Stratospheric Warming in the Southern Hemisphere
<p>Sudden stratospheric warmings (SSWs) are dynamic events associated with the rise in stratospheric temperature and the reversal in zonal mean zonal winds. SSWs are ...