Incidence and Predictors of Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement

View through CrossRef
BackgroundTranscatheter aortic valve replacement (TAVR) has emerged as an alternative treatment for patients with symptomatic aortic stenosis who are at high risk for surgical aortic valve replacement. The development of conduction abnormalities is a major complication in the postprocedural period of TAVR.ObjectivesThe objective of this study was to investigate the development of postprocedural conduction abnormalities and the requirement of permanent pacemaker (PPM) implantation in patients undergoing TAVR.MethodsData from 137 consecutive patients who underwent TAVR (Edwards SAPIEN valve, Edwards Lifesciences, Irvine, CA, USA) between June 2008 and October 2012 were reviewed. Patients with prior history of PPM (n = 27) were excluded. The role of various predictors for pacemaker implantation after TAVR, including the valve index (calculated as [valve size/left ventricular outflow tract diameter] × 100) was investigated.ResultsA total of 31/110 (28.2%) patients required implantation of a PPM after TAVR. The median time to implantation of a PPM was 5 days after the procedure. The development of postprocedural complete heart block was the most common indication for implantation of a PPM (16/31; 51.6%). On multivariate analysis, the presence of preexisting right bundle branch block (RBBB) was found to be a strong predictor of PPM implantation after TAVR (adjusted odds ratio: 4.87; 95% confidence interval: 1.29–18.46, P = 0.020). Using the receiver operated curve analysis, a cut‐off value of valve index of 128 was found to be a strong predictor for PPM implantation with a sensitivity of 73% and specificity of 61% (c statistic = 0.68).ConclusionsThis study identified the presence of prior RBBB and a valve index of 128 as important risk factors for PPM implantation after TAVR. A larger implanted valve size relative to left ventricular outflow tract diameter leads to a greater compression of the intrinsic conduction system, increasing the need for pacemaker placement.
Title: Incidence and Predictors of Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement
Description:
BackgroundTranscatheter aortic valve replacement (TAVR) has emerged as an alternative treatment for patients with symptomatic aortic stenosis who are at high risk for surgical aortic valve replacement.
The development of conduction abnormalities is a major complication in the postprocedural period of TAVR.
ObjectivesThe objective of this study was to investigate the development of postprocedural conduction abnormalities and the requirement of permanent pacemaker (PPM) implantation in patients undergoing TAVR.
MethodsData from 137 consecutive patients who underwent TAVR (Edwards SAPIEN valve, Edwards Lifesciences, Irvine, CA, USA) between June 2008 and October 2012 were reviewed.
Patients with prior history of PPM (n = 27) were excluded.
The role of various predictors for pacemaker implantation after TAVR, including the valve index (calculated as [valve size/left ventricular outflow tract diameter] × 100) was investigated.
ResultsA total of 31/110 (28.
2%) patients required implantation of a PPM after TAVR.
The median time to implantation of a PPM was 5 days after the procedure.
The development of postprocedural complete heart block was the most common indication for implantation of a PPM (16/31; 51.
6%).
On multivariate analysis, the presence of preexisting right bundle branch block (RBBB) was found to be a strong predictor of PPM implantation after TAVR (adjusted odds ratio: 4.
87; 95% confidence interval: 1.
29–18.
46, P = 0.
020).
Using the receiver operated curve analysis, a cut‐off value of valve index of 128 was found to be a strong predictor for PPM implantation with a sensitivity of 73% and specificity of 61% (c statistic = 0.
68).
ConclusionsThis study identified the presence of prior RBBB and a valve index of 128 as important risk factors for PPM implantation after TAVR.
A larger implanted valve size relative to left ventricular outflow tract diameter leads to a greater compression of the intrinsic conduction system, increasing the need for pacemaker placement.

Related Results

Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Permanent Pacemaker Implantation Following Aortic Valve Replacement: Current Prevalence and Clinical Predictors
Permanent Pacemaker Implantation Following Aortic Valve Replacement: Current Prevalence and Clinical Predictors
Background: The incidence of conduction disease requiring permanent pacemaker (PPM) implantation following aortic valve replacement (AVR) ranges from 3% to 6%....
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can occur in patients with prior conotruncal defect surgery, the Ross procedure, and connective tissue ...
Outcomes of permanent pacemaker implantation following transcatheter aortic valve replacement
Outcomes of permanent pacemaker implantation following transcatheter aortic valve replacement
Abstract Background Conduction abnormalities leading to permanent pacemaker (PPM) implantation are common complications followin...

Back to Top