Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Abstract 4145264: Balloon-expandable versus Self-expandable transcatheter aortic valve replacement for failed surgical prostheses: A systematic review and meta-analysis

View through CrossRef
Background: Transcatheter aortic valve-in-valve (VIV) replacement has emerged as a valid alternative to conventional re-operation for the treatment of failed bioprosthetic surgical aortic valves. Self-expandable valves (SEV) and balloon-expandable valves (BEV) are the two major devices used. The aim of this study is to compare outcomes between SEV and BEV when used for transcatheter aortic valve replacement (TAVR) procedures in failed surgical prostheses. <div> Methods: A comprehensive search was conducted on PubMed, Scopus, Web of Science, Cochrane Library, and Embase databases to identify studies comparing aortic valve in valve (ViV) with SEV and BEV for failed surgical aortic prostheses from inception to May 22, 2024. To estimate the effect size, dichotomous outcomes were pooled as risk ratio (RR), and continuous outcomes were pooled as mean difference (MD) with their respective 95% confidence interval (CI).</div> <div> Results: We included nine studies with a total of 1258 patients in the SEV group and 1079 in the BEV group. Compared to patients in the BEV group, patients in the SEV group had significantly lower one-year mortality (RR = 0.69; 95% CI: [0.49-0.98], p = 0.04). SEV group also had less incidence of severe patient protheses mismatch (RR = 0.49; 95% CI: [0.32-0.75], p <0.01). On the other hand, patients with SEV had a significantly higher risk of moderate to severe aortic regurgitation (AR) (RR = 2.71; 95% CI: [1.69-4.36], p = <0.01) as well as permanent pacemaker implantation (PPI) (RR = 1.63; 95% CI: [1.18 - 2.26], p <0.01). There was no difference in the rate of coronary obstruction (RR = 0.87; 95% CI: [ 0.49-1.55], p = 0.64), stroke (RR = 0.82; 95% CI: [0.42-1.58], p = 0.55), and short-term mortality (RR = 0.76; 95% CI: [0.49-1.18], p = 0.23) between both groups. One-year change in mean aortic valve gradient was comparable between both groups (MD = -13.94; 95% CI:[-31.16-3.28], p = 0.11).</div> <div> Conclusion: The present systematic review and meta-analysis found that for patients with failed surgical protheses who underwent transcatheter aortic VIV, SEV was associated with significantly less rate of one-year mortality and severe patients Prosthesis mismatch, but higher rates of PPI implantation and AR of moderate or higher degree. These findings provide valuable information in guiding proper selection of devices for patients with degenerated aortic surgical bioprostheses. </div> <div> </div>
Title: Abstract 4145264: Balloon-expandable versus Self-expandable transcatheter aortic valve replacement for failed surgical prostheses: A systematic review and meta-analysis
Description:
Background: Transcatheter aortic valve-in-valve (VIV) replacement has emerged as a valid alternative to conventional re-operation for the treatment of failed bioprosthetic surgical aortic valves.
Self-expandable valves (SEV) and balloon-expandable valves (BEV) are the two major devices used.
The aim of this study is to compare outcomes between SEV and BEV when used for transcatheter aortic valve replacement (TAVR) procedures in failed surgical prostheses.
<div> Methods: A comprehensive search was conducted on PubMed, Scopus, Web of Science, Cochrane Library, and Embase databases to identify studies comparing aortic valve in valve (ViV) with SEV and BEV for failed surgical aortic prostheses from inception to May 22, 2024.
To estimate the effect size, dichotomous outcomes were pooled as risk ratio (RR), and continuous outcomes were pooled as mean difference (MD) with their respective 95% confidence interval (CI).
</div> <div> Results: We included nine studies with a total of 1258 patients in the SEV group and 1079 in the BEV group.
Compared to patients in the BEV group, patients in the SEV group had significantly lower one-year mortality (RR = 0.
69; 95% CI: [0.
49-0.
98], p = 0.
04).
SEV group also had less incidence of severe patient protheses mismatch (RR = 0.
49; 95% CI: [0.
32-0.
75], p <0.
01).
On the other hand, patients with SEV had a significantly higher risk of moderate to severe aortic regurgitation (AR) (RR = 2.
71; 95% CI: [1.
69-4.
36], p = <0.
01) as well as permanent pacemaker implantation (PPI) (RR = 1.
63; 95% CI: [1.
18 - 2.
26], p <0.
01).
There was no difference in the rate of coronary obstruction (RR = 0.
87; 95% CI: [ 0.
49-1.
55], p = 0.
64), stroke (RR = 0.
82; 95% CI: [0.
42-1.
58], p = 0.
55), and short-term mortality (RR = 0.
76; 95% CI: [0.
49-1.
18], p = 0.
23) between both groups.
One-year change in mean aortic valve gradient was comparable between both groups (MD = -13.
94; 95% CI:[-31.
16-3.
28], p = 0.
11).
</div> <div> Conclusion: The present systematic review and meta-analysis found that for patients with failed surgical protheses who underwent transcatheter aortic VIV, SEV was associated with significantly less rate of one-year mortality and severe patients Prosthesis mismatch, but higher rates of PPI implantation and AR of moderate or higher degree.
These findings provide valuable information in guiding proper selection of devices for patients with degenerated aortic surgical bioprostheses.
</div> <div> </div>.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...
Small Aortic Annulus: Aortic Allografts vs Perceval S
Small Aortic Annulus: Aortic Allografts vs Perceval S
Цель. Оценить и сравнить гемодинамические показатели и изменение качества жизни после имплантации протезов Perceval S и аортальных аллографтов, а также частоту и спектр осложнений ...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, whic...

Back to Top