Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Pengujian Orifice Flow Meter dengan Kapasitas Aliran Rendah

View through CrossRef
Orifice flow meter is used in many laboratory and industrial application due because of its simple design and low cost. The present research investigated an orifice flow meter operated in relatively low flow rate. Orifice plate is a metal plate, 10 mm width provided with bevel at inlet section. The diameter ratios (β) are 0.3, 0.4, 0.5, 0.6, 0.7, and 0.8, respectively. The experiment used water with flowrate range having Reynolds number between 6827,55 and 8004,72. The fluid is flown through the orifice plate. Pressure taps are used to measure pressure at upstream and downstream of the orifice plate. The actual capacity is directly measured at an outlet reservoir; while the theoretical capacity is calculated using modified Bernoulli equation with diameter ratio (β) within the equation. The results showed that the irrecoverable pressure drop decreased with the increase of flow capacity and the diameter ratio. The discharge coefficient of the orifice flowmeter ranged between 0.3 and 1.3.
Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Lampung
Title: Pengujian Orifice Flow Meter dengan Kapasitas Aliran Rendah
Description:
Orifice flow meter is used in many laboratory and industrial application due because of its simple design and low cost.
The present research investigated an orifice flow meter operated in relatively low flow rate.
Orifice plate is a metal plate, 10 mm width provided with bevel at inlet section.
The diameter ratios (β) are 0.
3, 0.
4, 0.
5, 0.
6, 0.
7, and 0.
8, respectively.
The experiment used water with flowrate range having Reynolds number between 6827,55 and 8004,72.
The fluid is flown through the orifice plate.
Pressure taps are used to measure pressure at upstream and downstream of the orifice plate.
The actual capacity is directly measured at an outlet reservoir; while the theoretical capacity is calculated using modified Bernoulli equation with diameter ratio (β) within the equation.
The results showed that the irrecoverable pressure drop decreased with the increase of flow capacity and the diameter ratio.
The discharge coefficient of the orifice flowmeter ranged between 0.
3 and 1.
3.

Related Results

Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
Simulasi Aliran Fluida Crude Palm Oil (CPO) dan Air Pada Pipa Horizontal Menggunakan Metode Volume Hingga
Simulasi Aliran Fluida Crude Palm Oil (CPO) dan Air Pada Pipa Horizontal Menggunakan Metode Volume Hingga
Telah dilakukan simulasi aliran dua fasa cair- cair crude palm oil (CPO) dan air yang mengalir satu arah dalam pipa horizontal untuk mendapatkan pola aliran campuran dan karakteris...
PERBANDINGAN KINERJA WATER METER DIGITAL DAN WATER METER MEKANIK TERHADAP FINANSIAL PERUMDA AIR MINUM TIRTA AJI WONOSOBO
PERBANDINGAN KINERJA WATER METER DIGITAL DAN WATER METER MEKANIK TERHADAP FINANSIAL PERUMDA AIR MINUM TIRTA AJI WONOSOBO
PERUMDA Air Minum Tirta Aji Wonosobo meningkatkan pelayanan kepada pelanggan dengan pengembangan aksesoris berupa penggunaan water meter digital dan mekanik. Penelitian ini bertuju...
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet gas metering by differential pressure flow meters is gaining prominence in the oil and gas industry, owing to their simple construction. Slotted orifice, a modified version of ...
Studi terhadap Penumpukan Debris Kayu dengan Backwater Rise Kenaikan Muka Air pada Hulu Jembatan
Studi terhadap Penumpukan Debris Kayu dengan Backwater Rise Kenaikan Muka Air pada Hulu Jembatan
Debris flow is a phenomenon that occurs in both upstream and downstream watersheds. Heavy rains cause debris flow, which transports some of the material in the watershed, including...
Evaluation of a Close Coupled Slotted Orifice, Electric Impedance, and Swirl Flow Meters for Multiphase Flow
Evaluation of a Close Coupled Slotted Orifice, Electric Impedance, and Swirl Flow Meters for Multiphase Flow
The feasibility of a multiphase flow meter utilizing closely coupled slotted orifice and swirl flow meters along with an impedance sensor is investigated. The slotted flow meter ha...
Pengaruh Variasi Tebal Orifice dan Bilangan Reynolds (Re) terhadap Penurunan Tekanan (Pressure Drop) pada Entrance Region
Pengaruh Variasi Tebal Orifice dan Bilangan Reynolds (Re) terhadap Penurunan Tekanan (Pressure Drop) pada Entrance Region
Orifice is a device that is placed in a pipe flow to inhibit the flow of fluid and cause a pressure drop. The measurement of the flow rate (flow rate) is obtained from the differen...