Javascript must be enabled to continue!
Modeling of the Efficiency of the Centrifugal Conical Disk Dispenser of Bulk Materials
View through CrossRef
Centrifugal disk dispensers are widely used in various tasks of dosing bulk, dispersed materials. The design of the disk depends on the physical and mechanical characteristics of the dosing medium. The work discusses the development of an analytical model of the movement of a material particle along a conical centrifugal disk depending on the kinematic characteristics of the dosing process and the characteristics of the dosing material, as well as experimental confirmation of the theoretical model, which is relevant for the calculation and design of working elements of this type. The obtained system of differential equations is solved using the Runge–Kutta numerical method. Experimental studies were carried out using the method of a planned factorial experiment. The experiment was conducted for three factors at three levels. The feedback criterion was the performance of a centrifugal conical disk dispenser for bulk materials. The disk cone angle was set at 10, 20, and 30°. The disk diameter was 130, 150, and 170 mm, the gap between the disk and the edge of the hopper neck was 6, 8, and 10 mm, and the rotational speed of the conical disk was 0.65, 1.02, and 1.39 rad/s. The dispensing rate of the dispenser ranged from 15 to 770 g/s, depending on the values of the experimental factors. For use in the regression equation of the natural values of the factors, a method of transforming the terms of the equation from coded values to natural ones is provided. The obtained experimental correlation dependencies were checked for reproducibility with Cochrane’s test, and the adequacy of the model was checked using Fisher’s test. The significance of the coefficients in the correlation equation was evaluated using the Student’s t-test. The difference between the experimental data and the results of the theoretical modeling does not exceed 5%. The obtained system of differential equations makes it possible to model the radial velocity of the ascent of bulk material from the conical rotating disk depending on the rotation frequency, disk diameter, and the height of the annular gap between the discharge throat of the hopper and the conical disk. The analytical model enables the modeling of the productivity of the conical dispenser for bulk materials for arbitrary parameters of rotation frequency, disk diameter, and the size of the annular gap between the discharge throat of the hopper and the conical disk.
Title: Modeling of the Efficiency of the Centrifugal Conical Disk Dispenser of Bulk Materials
Description:
Centrifugal disk dispensers are widely used in various tasks of dosing bulk, dispersed materials.
The design of the disk depends on the physical and mechanical characteristics of the dosing medium.
The work discusses the development of an analytical model of the movement of a material particle along a conical centrifugal disk depending on the kinematic characteristics of the dosing process and the characteristics of the dosing material, as well as experimental confirmation of the theoretical model, which is relevant for the calculation and design of working elements of this type.
The obtained system of differential equations is solved using the Runge–Kutta numerical method.
Experimental studies were carried out using the method of a planned factorial experiment.
The experiment was conducted for three factors at three levels.
The feedback criterion was the performance of a centrifugal conical disk dispenser for bulk materials.
The disk cone angle was set at 10, 20, and 30°.
The disk diameter was 130, 150, and 170 mm, the gap between the disk and the edge of the hopper neck was 6, 8, and 10 mm, and the rotational speed of the conical disk was 0.
65, 1.
02, and 1.
39 rad/s.
The dispensing rate of the dispenser ranged from 15 to 770 g/s, depending on the values of the experimental factors.
For use in the regression equation of the natural values of the factors, a method of transforming the terms of the equation from coded values to natural ones is provided.
The obtained experimental correlation dependencies were checked for reproducibility with Cochrane’s test, and the adequacy of the model was checked using Fisher’s test.
The significance of the coefficients in the correlation equation was evaluated using the Student’s t-test.
The difference between the experimental data and the results of the theoretical modeling does not exceed 5%.
The obtained system of differential equations makes it possible to model the radial velocity of the ascent of bulk material from the conical rotating disk depending on the rotation frequency, disk diameter, and the height of the annular gap between the discharge throat of the hopper and the conical disk.
The analytical model enables the modeling of the productivity of the conical dispenser for bulk materials for arbitrary parameters of rotation frequency, disk diameter, and the size of the annular gap between the discharge throat of the hopper and the conical disk.
Related Results
Antibiogram of Escherichia coli isolated from semi-closed system farmed Asian clam (Corbicula fluminea)
Antibiogram of Escherichia coli isolated from semi-closed system farmed Asian clam (Corbicula fluminea)
In the present study, antibiogram of Escherichia coli isolated from farmed Asian clam, Corbiculafluminea was characterised. Asian clam or locally known as ‘etak’ is processed to be...
Collision Analysis for Multiple Satellites Released from a Common Dispenser
Collision Analysis for Multiple Satellites Released from a Common Dispenser
With the increasing demand for multiple satellites released in a single launch being supported by developments in both rocketry and satellite manufacturing, risks of having collisi...
Snapshot of a magnetohydrodynamic disk wind
Snapshot of a magnetohydrodynamic disk wind
Abstract
The formation of astrophysical objects of different nature and size, from black holes to gaseous giant planets, involves a disk-jet system, where the disk drives t...
Integrated switchable ventricular assist devices for pediatric patients
Integrated switchable ventricular assist devices for pediatric patients
Thousands of children are born each year with significant cardiac defects that result in the development of heart disease and ultimately premature congestive heart failure (CHF). I...
CONVERSION OF CHARACTERISTICS OF CENTRIFUGAL PUMPS TO VISCOUS LIQUIDS
CONVERSION OF CHARACTERISTICS OF CENTRIFUGAL PUMPS TO VISCOUS LIQUIDS
The urgency of the work is due to the large use of modern industry centrifugal pumps for pumping viscous liquids. In the energy sector, this is the use of fuel oil and thermal powe...
EFFICIENCY OF A MODIFIED CONICAL METALLIC COOKING STOVE INCORPORATING CLAY FOR OPTIMAL CHARCOAL CONSUMPTION IN KARA REGION - TOGO
EFFICIENCY OF A MODIFIED CONICAL METALLIC COOKING STOVE INCORPORATING CLAY FOR OPTIMAL CHARCOAL CONSUMPTION IN KARA REGION - TOGO
An acceptability survey of improved charcoal stoves conducted in some households in the Kara region in Togo revealed that 40% of households use the clay cookestove and 30% the coni...
Improvement of Methadone Maintenance Treatment (MMT) Process Through Development and Implementation of Methadone Dispenser
Improvement of Methadone Maintenance Treatment (MMT) Process Through Development and Implementation of Methadone Dispenser
Abstract
Methadone is a controlled drug and can be prescribed by an authorized person in charge, under the direction of medical practitioners, for particular patient...
Bioconvection dynamics in rotating and stationary cone-disk systems
Bioconvection dynamics in rotating and stationary cone-disk systems
This work focuses on the study of bioconvection in a conical region of rotating and stationary cone-disk systems utilizing nanofluids involving gyrotactic micro-organisms. The flow...

