Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Single-Disk and Double-Disk Viscous Micropump

View through CrossRef
The development and testing of two novel micropumps called the single-disk and double-disk viscous pumps are described. A single disk and the top pump housing, or two disks are separated by a small gap that forms a fluid passage. A wiper, that is the height of this gap, is placed between the two disks, or between the single disk and top pump housing, and extends from the outer diameter of the disk(s) to the center region of the disk(s). The movement of the disk(s) induces viscous stresses on the fluid that forces the fluid through the pump area above the single disk, or between the two disks. The wiper acts to “wipe” the fluid from the disk(s) toward the outlet channel. The fluid flow through the double-disk pump is visualized using a red Rhodamine dye that is injected into the fluid passage upstream of the pumping area. Experimental flow rate for the single-disk and double-disk pumps are obtained for a disk diameter of 2.381 mm, and a gap height of 103 μm. The maximum flow rates obtained are 0.74 ml/min and 2.1 ml/min for the single-disk and double-disk pumps, respectively, for a rotational speed of 5000 rpm. Advantages of the disk pumps include simplicity of design, planar structure, continuous flow, well controlled flow rate, and mixing characteristics.
Title: Single-Disk and Double-Disk Viscous Micropump
Description:
The development and testing of two novel micropumps called the single-disk and double-disk viscous pumps are described.
A single disk and the top pump housing, or two disks are separated by a small gap that forms a fluid passage.
A wiper, that is the height of this gap, is placed between the two disks, or between the single disk and top pump housing, and extends from the outer diameter of the disk(s) to the center region of the disk(s).
The movement of the disk(s) induces viscous stresses on the fluid that forces the fluid through the pump area above the single disk, or between the two disks.
The wiper acts to “wipe” the fluid from the disk(s) toward the outlet channel.
The fluid flow through the double-disk pump is visualized using a red Rhodamine dye that is injected into the fluid passage upstream of the pumping area.
Experimental flow rate for the single-disk and double-disk pumps are obtained for a disk diameter of 2.
381 mm, and a gap height of 103 μm.
The maximum flow rates obtained are 0.
74 ml/min and 2.
1 ml/min for the single-disk and double-disk pumps, respectively, for a rotational speed of 5000 rpm.
Advantages of the disk pumps include simplicity of design, planar structure, continuous flow, well controlled flow rate, and mixing characteristics.

Related Results

Electrostatically driven micropump with peristaltically moving membrane
Electrostatically driven micropump with peristaltically moving membrane
An electrostatically driven valveless micropump with a peristaltically moving membrane for gas chromatography is presented. The one‐chamber micropump has a peristaltically moving m...
A SUPERIMPOSED VALVELESS MICROPUMP USING NEW CHANNELS FOR OPTIMAL DRUG DELIVERY
A SUPERIMPOSED VALVELESS MICROPUMP USING NEW CHANNELS FOR OPTIMAL DRUG DELIVERY
In this paper, we propose a valveless micropump with an improved inlet/outlet channel configuration for biomedical applications. To do so, we added curved parts known as "ears" to ...
Characterization of a 3D Printed Self-Powered Micropump Mould for Microfluidics Application
Characterization of a 3D Printed Self-Powered Micropump Mould for Microfluidics Application
The number of words should not exceed 350 Self-powered infusion micropump is a non-mechanical micropumps for microfluidics application. A three- dimensional (3D) printing is an int...
Immiscible Viscous Fingering: the Effects of Wettability/Capillarity and Scaling
Immiscible Viscous Fingering: the Effects of Wettability/Capillarity and Scaling
Abstract Realistic immiscible viscous fingering, showing all of the complex finger structure observed in experiments, has proved to be very difficult to model using direct ...
A Bioinspired Active Micropump
A Bioinspired Active Micropump
A preliminary design concept is provided for a bioinspired active micropump. The proposed micropump uses light energy to activate the transporter proteins (bacteriorhodopsin protei...
Development of High-Power Micropump Using Inertia Effect of Fluid for Small-Sized Fluid Actuators
Development of High-Power Micropump Using Inertia Effect of Fluid for Small-Sized Fluid Actuators
The authors have been developing a high output micropump for the small but powerful fluid actuator which has a source of fluid power individually. In this paper, a novel piezoelect...
Antibiogram of Escherichia coli isolated from semi-closed system farmed Asian clam (Corbicula fluminea)
Antibiogram of Escherichia coli isolated from semi-closed system farmed Asian clam (Corbicula fluminea)
In the present study, antibiogram of Escherichia coli isolated from farmed Asian clam, Corbiculafluminea was characterised. Asian clam or locally known as ‘etak’ is processed to be...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract Introduction Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...

Back to Top