Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The presence of helical flow can suppress areas of disturbed shear in parameterised models of an arteriovenous fistula

View through CrossRef
AbstractAreas of disturbed shear that develop following arteriovenous fistula (AVF) creation are believed to trigger the onset of intimal hyperplasia (IH), leading to AVF dysfunction. The presence of helical flow can suppress the flow disturbances that lead to disturbed shear in other areas of the vasculature. However, the relationship between helical flow and disturbed shear remains unevaluated in AVF. In this study, computational fluid dynamics (CFD) is used to evaluate the relationship between geometry, helical flow, and disturbed shear in parameterised models of an AVF characterised by four different anastomosis angles. The AVF models with a small anastomosis angle demonstrate the lowest distribution of low/oscillating shear and are characterised by a high helical intensity coupled with a strong balance between helical structures. Contrastingly, the models with a large anastomosis angle experience the least amount of high shear, multidirectional shear, as well as spatial and temporal gradients of shear. Furthermore, the intensity of helical flow correlates strongly with curvature (r = 0.73, P < .001), whereas it is strongly and inversely associated with taper (r = −0.87, P < .001). In summary, a flow field dominated by a high helical intensity coupled with a strong balance between helical structures can suppress exposure to low/oscillating shear but is ineffective when it comes to other types of shear. This highlights the clinical potential of helical flow as a diagnostic marker of exposure to low/oscillating shear, as helical flow can be identified in vivo with the use of ultrasound imaging.
Title: The presence of helical flow can suppress areas of disturbed shear in parameterised models of an arteriovenous fistula
Description:
AbstractAreas of disturbed shear that develop following arteriovenous fistula (AVF) creation are believed to trigger the onset of intimal hyperplasia (IH), leading to AVF dysfunction.
The presence of helical flow can suppress the flow disturbances that lead to disturbed shear in other areas of the vasculature.
However, the relationship between helical flow and disturbed shear remains unevaluated in AVF.
In this study, computational fluid dynamics (CFD) is used to evaluate the relationship between geometry, helical flow, and disturbed shear in parameterised models of an AVF characterised by four different anastomosis angles.
The AVF models with a small anastomosis angle demonstrate the lowest distribution of low/oscillating shear and are characterised by a high helical intensity coupled with a strong balance between helical structures.
Contrastingly, the models with a large anastomosis angle experience the least amount of high shear, multidirectional shear, as well as spatial and temporal gradients of shear.
Furthermore, the intensity of helical flow correlates strongly with curvature (r = 0.
73, P < .
001), whereas it is strongly and inversely associated with taper (r = −0.
87, P < .
001).
In summary, a flow field dominated by a high helical intensity coupled with a strong balance between helical structures can suppress exposure to low/oscillating shear but is ineffective when it comes to other types of shear.
This highlights the clinical potential of helical flow as a diagnostic marker of exposure to low/oscillating shear, as helical flow can be identified in vivo with the use of ultrasound imaging.

Related Results

Women’s knowledge of symptoms of obstetric fistula, experiences, and associated factors in Sierra Leone
Women’s knowledge of symptoms of obstetric fistula, experiences, and associated factors in Sierra Leone
Background Obstetric fistula is a devastating childbirth condition that results from prolonged obstructed labour without timely medical intervention, leading to a tear between the ...
The efficacy of Percutaneous transluminal angioplasty and Arteriovenous fistula reconstruction for immature arteriovenous fistula
The efficacy of Percutaneous transluminal angioplasty and Arteriovenous fistula reconstruction for immature arteriovenous fistula
Abstract Background To access the efficacy of percutaneous transluminal angioplasty and arteriovenous fistula reconstruction for immature arteriovenous fistula, compare th...
Risk factors for failed fistula closure in Addis Ababa at fistula centre, central Ethiopia
Risk factors for failed fistula closure in Addis Ababa at fistula centre, central Ethiopia
BackgroundObstetric Fistula leads to fecal and urine incontinence in women and girls. Surgical repair is the cornerstone of care. Failure to repair an obstetric fistula exposes wom...
Cartoid-cavernous fistula – diagnostic problems
Cartoid-cavernous fistula – diagnostic problems
<b>Introduction.</b> Carotid-cavernous arteriovenous fistula is an abnormal connection between the internal or external carotid arteries and the brain venous system wit...
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Optimization of magnetoelectricity in thickness shear mode LiNbO3/magnetostrictive laminated composite
Magnetoelectric (ME) composites have recently attracted much attention and triggered a great number of research activities, owing to their potential applications in sensors and tra...
The Treatment of Congenital Recto-vestibular Fistula and Recto-perineal Fistula, and the Effects of the Megarectum on Defecation
The Treatment of Congenital Recto-vestibular Fistula and Recto-perineal Fistula, and the Effects of the Megarectum on Defecation
Objective: This study aims to discuss the treatment of congenital recto-vestibular fistula and recto-perineal fistula, and the effect of the megarectum on defecation. Background:...

Back to Top