Javascript must be enabled to continue!
Analisis Daya Dukung Fondasi Bored Pile Pada Rumah Sakit Sultan Imanuddin Pangkalan Bun
View through CrossRef
This study intended to analyze the bearing capacity of single bored pile, the bearing capacity of the bored pile group, the load carried, the safety factor, and the settlement that occurs. The first calculation method is Schmertmann and Nottingham method, and the second calculation method is Meyerhof method. Based on the calculation of the bearing capacity of a single bored pile using the Schmertmann and Nottingham method obtained a value Qu = 49005,88 kN, while the Meyerhof method obtained a value Qu = 1633.71 kN. The calculation results for bearing capacity of the pile group using the Schmertmann and Nottingham method obtained a value Qg = 164169,70 kN and the Meyerhof method obtained a value Qg = 5472.93 kN. The results of the load carried by the bored pile group using Schmertmann and Nottingham method is Qi = 353.98 kN ≤ Qg = 164169.70 kN which means it’s still within safe limits. Using the Meyerhof method is Qi = 353.98 kN ≤ Qg = 5472.93 kN which means it is still within safe limits. The safety factor using the Schmertmann and Nottingham method obtained SF = 463.78 and using the Meyerhof method obtained SF = 15.46 which means it is very safe. Total settlement of a single bored pile is S = 0.0142 m ≤ 0.04 m which means it is safe. And the settlement of the bored pile group is Sg = 0.03 m ≤ 0.08 m which also means it is safe
Universitas Muhammadiyah Palangkaraya
Title: Analisis Daya Dukung Fondasi Bored Pile Pada Rumah Sakit Sultan Imanuddin Pangkalan Bun
Description:
This study intended to analyze the bearing capacity of single bored pile, the bearing capacity of the bored pile group, the load carried, the safety factor, and the settlement that occurs.
The first calculation method is Schmertmann and Nottingham method, and the second calculation method is Meyerhof method.
Based on the calculation of the bearing capacity of a single bored pile using the Schmertmann and Nottingham method obtained a value Qu = 49005,88 kN, while the Meyerhof method obtained a value Qu = 1633.
71 kN.
The calculation results for bearing capacity of the pile group using the Schmertmann and Nottingham method obtained a value Qg = 164169,70 kN and the Meyerhof method obtained a value Qg = 5472.
93 kN.
The results of the load carried by the bored pile group using Schmertmann and Nottingham method is Qi = 353.
98 kN ≤ Qg = 164169.
70 kN which means it’s still within safe limits.
Using the Meyerhof method is Qi = 353.
98 kN ≤ Qg = 5472.
93 kN which means it is still within safe limits.
The safety factor using the Schmertmann and Nottingham method obtained SF = 463.
78 and using the Meyerhof method obtained SF = 15.
46 which means it is very safe.
Total settlement of a single bored pile is S = 0.
0142 m ≤ 0.
04 m which means it is safe.
And the settlement of the bored pile group is Sg = 0.
03 m ≤ 0.
08 m which also means it is safe.
Related Results
Analysis Of Three-Dimensional Pile Groups With Nonlinear Soil Response And Pile-Soil-Pile Interaction
Analysis Of Three-Dimensional Pile Groups With Nonlinear Soil Response And Pile-Soil-Pile Interaction
ABSTRACT
Present methods of pile group analysis are either limited to special geometric cases or do not consider pile-soil-pile interaction. An analytical procedu...
STUDI PERBANDINGAN DAYA DUKUNG PONDASI TIANG TUNGGAL DAN TIANG KELOMPOK DENGAN BEBERAPA VARIASI DIMENSI PENAMPANG TIANG DITINJAU TERHADAP NILAI EKONOMIS (Studi Kasus: Pembangunan Gedung Rektorat UNISKA MAB Banjarmasin)
STUDI PERBANDINGAN DAYA DUKUNG PONDASI TIANG TUNGGAL DAN TIANG KELOMPOK DENGAN BEBERAPA VARIASI DIMENSI PENAMPANG TIANG DITINJAU TERHADAP NILAI EKONOMIS (Studi Kasus: Pembangunan Gedung Rektorat UNISKA MAB Banjarmasin)
Gedung Rektorat Universitas Islam Kalimantan (UNISKA) Muhammad Arsyad Al Banjari (MAB) adalah proyek strategis yang bertujuan untuk meningkatkan kualitas infrastruktur pendidikan d...
ANALISIS PENGARUH DIAMETER TIANG TERHADAP DAYA DUKUNG LATERAL FONDASI TIANG TUNGGAL DENGAN PEMBEBANAN STATIK DAN SIKLIK
ANALISIS PENGARUH DIAMETER TIANG TERHADAP DAYA DUKUNG LATERAL FONDASI TIANG TUNGGAL DENGAN PEMBEBANAN STATIK DAN SIKLIK
The pile foundation is a frequently chosen option in constructing multi-story buildings, where the vertical load is substantial and needs to be transferred to hard soil/strata. Mul...
PERENCANAAN FONDASI TIANG PANCANG PADA PROYEK TOWER 2 ARANDRA RESIDENCE
PERENCANAAN FONDASI TIANG PANCANG PADA PROYEK TOWER 2 ARANDRA RESIDENCE
ABSTRACTThe pile foundation is an sub-structure to load from the upper structure. Ultimate load carrying-capacity (qu) will be transfered into a hard soil layer by using a deep fou...
PERTANGGUNGJAWABAN PIDANA RUMAH SAKIT TERHADAP TINDAK PIDANA PEMALSUAN JUMLAH TAGIHAN UANG KEPADA BADAN PENYELENGGARA JAMINAN SOSIAL (BPJS)
PERTANGGUNGJAWABAN PIDANA RUMAH SAKIT TERHADAP TINDAK PIDANA PEMALSUAN JUMLAH TAGIHAN UANG KEPADA BADAN PENYELENGGARA JAMINAN SOSIAL (BPJS)
PERTANGGUNGJAWABAN PIDANA RUMAH SAKIT TERHADAP TINDAK PIDANA PEMALSUAN JUMLAH TAGIHAN UANG KEPADA BADAN PENYELENGGARA JAMINAN SOSIAL (BPJS)
sonyaairinibatubara@unprim...
Simplified Heat Transfer Model for Spiral‐Coil Energy Pile Groups and the Pile–Pile Thermal Interference
Simplified Heat Transfer Model for Spiral‐Coil Energy Pile Groups and the Pile–Pile Thermal Interference
ABSTRACTThe spiral heat exchanger of the energy pile groups is divided into multiple segments. Each heat exchanger segment is regarded as a three‐dimensional spiral heat source of ...
Pile–Soil Interaction and Group Pile Effect in Composite Foundation Under Different Pile Length Conditions
Pile–Soil Interaction and Group Pile Effect in Composite Foundation Under Different Pile Length Conditions
With the rapid development of urbanization and infrastructure construction, the requirements for the foundation design of high-rise buildings and large bridges are increasing. Pile...
Analisis Daya Dukung Pondasi Spun Pile Dievaluasi Dengan Kalendering Dan PDA
Analisis Daya Dukung Pondasi Spun Pile Dievaluasi Dengan Kalendering Dan PDA
Dalam suatu proyek konstruksi jembatan, terdapat dua jenis struktur, yaitu struktur atas dan struktur bawah. Pondasi merupakan bagian dari struktur bawah yang berfungsi sebagai pen...