Javascript must be enabled to continue!
Carbon Paste Electrode Modified with PMBP: A Sensitive Sensor for Electrochemical Detection of Acetaminophen
View through CrossRef
In this present work, a sensitive electrocatalytic modified electrode based on 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP)/multiwalled carbon nanotubes (MWCNT) modified carbon paste electrode (CPE) was successfully developed. Electrochemical impedance spectroscopy, square wave voltammetry, chronocoulometry and cyclic voltammetry were used in prompt to evaluate the PMBP/MWCNT/CPE electrochemical capacity in detecting acetaminophen (APAP) in 0.1 M PBS pH 6.4. Under optimized conditions, PMBP/MWCNT/CPE displayed a well-defined electrocatalytic activity towards APAP oxidation in the linear responses which range from 1 μM to 1 mM (R2 = 0.991) with the LOD obtained at 0.245 μM while LOQ 0.816 μM. The presence of excess (10-fold and 25-fold) interferents such as sucrose, fructose, glucose, sodium chloride, sodium sulphate, potassium nitrate, lysine, potassium chloride and magnesium chloride as interferents was insignificant. The results presented in this study provide new perspectives on PMBP as a potential nanomaterial in the development of APAP sensors. As a conclusion, the PMBP/MWCNT/CPE revealed good stability, reproducibility, and repeatability, and was discovered to be relevant for usage in the pharmaceutical samples with satisfactory performance.
Chemical Society of Pakistan
Title: Carbon Paste Electrode Modified with PMBP: A Sensitive Sensor for Electrochemical Detection of Acetaminophen
Description:
In this present work, a sensitive electrocatalytic modified electrode based on 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP)/multiwalled carbon nanotubes (MWCNT) modified carbon paste electrode (CPE) was successfully developed.
Electrochemical impedance spectroscopy, square wave voltammetry, chronocoulometry and cyclic voltammetry were used in prompt to evaluate the PMBP/MWCNT/CPE electrochemical capacity in detecting acetaminophen (APAP) in 0.
1 M PBS pH 6.
4.
Under optimized conditions, PMBP/MWCNT/CPE displayed a well-defined electrocatalytic activity towards APAP oxidation in the linear responses which range from 1 μM to 1 mM (R2 = 0.
991) with the LOD obtained at 0.
245 μM while LOQ 0.
816 μM.
The presence of excess (10-fold and 25-fold) interferents such as sucrose, fructose, glucose, sodium chloride, sodium sulphate, potassium nitrate, lysine, potassium chloride and magnesium chloride as interferents was insignificant.
The results presented in this study provide new perspectives on PMBP as a potential nanomaterial in the development of APAP sensors.
As a conclusion, the PMBP/MWCNT/CPE revealed good stability, reproducibility, and repeatability, and was discovered to be relevant for usage in the pharmaceutical samples with satisfactory performance.
Related Results
Pengabdian Sosial Berbasis Potensi Pelatihan Canvativity dan Fokus Cipta Puisi
Pengabdian Sosial Berbasis Potensi Pelatihan Canvativity dan Fokus Cipta Puisi
Pengabdian Masyarakat Berbasis Potensi (PMBP) merupakan salah satu bentuk kegiatan pengabdian yang dilakukan oleh mahasiswa Universitas Insan Budi Utomo Malang dalam lingkungan sek...
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Introduction
Heavy metal pollution seriously affects human health. Mercury is one of the most hazardous pollution, it has been accum...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Boosting Oxygen Electrode Performance via a Redox-Treatment
Boosting Oxygen Electrode Performance via a Redox-Treatment
Introduction
The transition to a sustainable energy system complying with climate policy targets is a huge societal challenge. “Hard to electri...
Supercapacitive MnO2/PEDOT: PSS Modified 3D-Printed Polymeric Micro-Pillar Electrode for Extraction of Photosynthetic Electrons
Supercapacitive MnO2/PEDOT: PSS Modified 3D-Printed Polymeric Micro-Pillar Electrode for Extraction of Photosynthetic Electrons
Photosynthetic bio-electrochemical cells (PBECs) have been reported as having promising potential for the renewable energy field. When photosynthesis occurs, photosynthetic electro...
Multiple Biomarker Responses in Female Catfish (Clarias Gariepinus) Exposed to Acetaminophen
Multiple Biomarker Responses in Female Catfish (Clarias Gariepinus) Exposed to Acetaminophen
Abstract
Acetaminophen is one of the most commonly detected Analgesics and pain killer drug in freshwater environments. This study evaluated the ...
Acute Acetaminophen Overdose Is Associated with Dose‐Dependent Hypokalaemia: A Prospective Study of 331 Patients
Acute Acetaminophen Overdose Is Associated with Dose‐Dependent Hypokalaemia: A Prospective Study of 331 Patients
Abstract: Hypokalaemia is a recognized complication of acute acetaminophen overdose. It is unclear whether this might be a pharmacological effect of acetaminophen, or due to assoc...
Molecularly imprinted polyaniline‐modified electrode for quantitative detection of acetaminophen
Molecularly imprinted polyaniline‐modified electrode for quantitative detection of acetaminophen
AbstractIn this work, a voltammetry sensor was prepared using the general molecularly imprinted polymer (MIP) method based on polyaniline for detection of acetaminophen (ACT). The ...