Molecularly imprinted polyaniline‐modified electrode for quantitative detection of acetaminophen
View through CrossRef
AbstractIn this work, a voltammetry sensor was prepared using the general molecularly imprinted polymer (MIP) method based on polyaniline for detection of acetaminophen (ACT). The polyaniline molecularly imprinted polymer was made by electropolymerization of aniline in the presence of acetaminophen as a template using power supply, and then acetaminophen was separated from the polymer by solvent extraction method. Different concentrations of ACT were detected using cyclic voltammetry (CV) in water‐ethanol solution, and a calibration curve with a limit of detection (LOD) and limit of quantification (LOQ) of 0.43 and 1.42 ppm, respectively, was reported along with a linear equation. The sensor showed a linear range between 5 and 40 ppm for acetaminophen detection. To investigate the selectivity of the reported sensor, a copper electrode was used to detect ACT and an ibuprofen solution was used as analyte for detection by the ACT‐MIP sensor. Additionally, the nonimprinted polymer (NIP) did not show any significant peak in the presence of ACT. This sensor was able to detect acetaminophen dissolved in a real urine sample successfully. This novel sensor is prepared from polyaniline, which is a conductive polymer, and no other reinforcements are needed for the sensor's conductivity in the presence of template molecule, which in this paper is acetaminophen.
Title: Molecularly imprinted polyaniline‐modified electrode for quantitative detection of acetaminophen
Description:
AbstractIn this work, a voltammetry sensor was prepared using the general molecularly imprinted polymer (MIP) method based on polyaniline for detection of acetaminophen (ACT).
The polyaniline molecularly imprinted polymer was made by electropolymerization of aniline in the presence of acetaminophen as a template using power supply, and then acetaminophen was separated from the polymer by solvent extraction method.
Different concentrations of ACT were detected using cyclic voltammetry (CV) in water‐ethanol solution, and a calibration curve with a limit of detection (LOD) and limit of quantification (LOQ) of 0.
43 and 1.
42 ppm, respectively, was reported along with a linear equation.
The sensor showed a linear range between 5 and 40 ppm for acetaminophen detection.
To investigate the selectivity of the reported sensor, a copper electrode was used to detect ACT and an ibuprofen solution was used as analyte for detection by the ACT‐MIP sensor.
Additionally, the nonimprinted polymer (NIP) did not show any significant peak in the presence of ACT.
This sensor was able to detect acetaminophen dissolved in a real urine sample successfully.
This novel sensor is prepared from polyaniline, which is a conductive polymer, and no other reinforcements are needed for the sensor's conductivity in the presence of template molecule, which in this paper is acetaminophen.
Related Results
Effects of Garnoderma lucidum on Acetaminophen-Induced Liver Injury in Wistar Rats
Effects of Garnoderma lucidum on Acetaminophen-Induced Liver Injury in Wistar Rats
Introduction: Ganoderma lucidum is considered to be a medicinal mushroom, widely used to prevent or treat different types of diseases including cancer, cardiovascular disease and h...
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Trace Mercury Ion Detection Sensor Employing SnO2/Rgo Nanocomposites Modified Electrode
Introduction
Heavy metal pollution seriously affects human health. Mercury is one of the most hazardous pollution, it has been accum...
Genomic imprinted genes in reciprocal hybrid endosperm of Brassica napus
Genomic imprinted genes in reciprocal hybrid endosperm of Brassica napus
AbstractBackgroundGenomic imprinting results in the expression of parent-of-origin-specific alleles in the offspring.Brassica napusis an oil crop with research values in polyploidi...
Trends on the Development of Hybrid Supercapacitor Electrodes from the Combination of Graphene and Polyaniline
Trends on the Development of Hybrid Supercapacitor Electrodes from the Combination of Graphene and Polyaniline
The high demand for efficient energy devices leads to the rapid development of energy storage systems with excellent electrochemical properties, such as long life cycles, high cycl...
Validation of ICD-9-CM/ICD-10 coding algorithms for the identification of patients with acetaminophen overdose and hepatotoxicity using administrative data
Validation of ICD-9-CM/ICD-10 coding algorithms for the identification of patients with acetaminophen overdose and hepatotoxicity using administrative data
Abstract
Background
Acetaminophen overdose is the most common cause of acute liver failure (ALF). Our objective was to develop coding algorithms usi...
Recent Applications of Molecularly Imprinted Sol-Gel Methodology in Sample Preparation
Recent Applications of Molecularly Imprinted Sol-Gel Methodology in Sample Preparation
Due to their selectivity and chemical stability, molecularly imprinted polymers have attracted great interest in sample preparation. Imprinted polymers have been applied for the ex...
Performance Evaluation of Electrode Fabricated by using FDM in Die-Sinking EDM
Performance Evaluation of Electrode Fabricated by using FDM in Die-Sinking EDM
An electrode is a vital transmission tool of electrical charges that erodes a workpiece surface in die-sinking electrical discharge machining (EDM). However, the demanding requirem...
Preparation and anticorrosion properties of polyaniline‐containing coating on Mg‐Li alloy
Preparation and anticorrosion properties of polyaniline‐containing coating on Mg‐Li alloy
PurposeThe purpose of this investigation was to synthesize a doped polyaniline‐containing coating and investigate the anti‐corrosion properties of the coating on Mg‐Li alloy.Design...