Molecularly imprinted polyaniline‐modified electrode for quantitative detection of acetaminophen

View through CrossRef
AbstractIn this work, a voltammetry sensor was prepared using the general molecularly imprinted polymer (MIP) method based on polyaniline for detection of acetaminophen (ACT). The polyaniline molecularly imprinted polymer was made by electropolymerization of aniline in the presence of acetaminophen as a template using power supply, and then acetaminophen was separated from the polymer by solvent extraction method. Different concentrations of ACT were detected using cyclic voltammetry (CV) in water‐ethanol solution, and a calibration curve with a limit of detection (LOD) and limit of quantification (LOQ) of 0.43 and 1.42 ppm, respectively, was reported along with a linear equation. The sensor showed a linear range between 5 and 40 ppm for acetaminophen detection. To investigate the selectivity of the reported sensor, a copper electrode was used to detect ACT and an ibuprofen solution was used as analyte for detection by the ACT‐MIP sensor. Additionally, the nonimprinted polymer (NIP) did not show any significant peak in the presence of ACT. This sensor was able to detect acetaminophen dissolved in a real urine sample successfully. This novel sensor is prepared from polyaniline, which is a conductive polymer, and no other reinforcements are needed for the sensor's conductivity in the presence of template molecule, which in this paper is acetaminophen.
Title: Molecularly imprinted polyaniline‐modified electrode for quantitative detection of acetaminophen
Description:
AbstractIn this work, a voltammetry sensor was prepared using the general molecularly imprinted polymer (MIP) method based on polyaniline for detection of acetaminophen (ACT).
The polyaniline molecularly imprinted polymer was made by electropolymerization of aniline in the presence of acetaminophen as a template using power supply, and then acetaminophen was separated from the polymer by solvent extraction method.
Different concentrations of ACT were detected using cyclic voltammetry (CV) in water‐ethanol solution, and a calibration curve with a limit of detection (LOD) and limit of quantification (LOQ) of 0.
43 and 1.
42 ppm, respectively, was reported along with a linear equation.
The sensor showed a linear range between 5 and 40 ppm for acetaminophen detection.
To investigate the selectivity of the reported sensor, a copper electrode was used to detect ACT and an ibuprofen solution was used as analyte for detection by the ACT‐MIP sensor.
Additionally, the nonimprinted polymer (NIP) did not show any significant peak in the presence of ACT.
This sensor was able to detect acetaminophen dissolved in a real urine sample successfully.
This novel sensor is prepared from polyaniline, which is a conductive polymer, and no other reinforcements are needed for the sensor's conductivity in the presence of template molecule, which in this paper is acetaminophen.

Related Results

Sensor Gas Amonia Berbasis Polimer Konduktif Polianilina: Sebuah Review
Sensor Gas Amonia Berbasis Polimer Konduktif Polianilina: Sebuah Review
Artikel review ini memberikan informasi tentang aplikasi polianilina (PANI) dan kompositnya sebagai sensor gas berbahaya khususnya amonia (NH3). Kajian yang dibahas pada artikel in...
Developing Molecular Imprinted Layers As Electro-Analytical Probes for Dydrogesterone Determination
Developing Molecular Imprinted Layers As Electro-Analytical Probes for Dydrogesterone Determination
Dydrogesterone is a synthetic derivative of female sex hormone whose structure and pharmacological action is similar to progesterone. This drug is used in various conditions includ...
Molecularly Imprinted Polyacrylamide with Fluorescent Nanodiamond for Creatinine Detection
Molecularly Imprinted Polyacrylamide with Fluorescent Nanodiamond for Creatinine Detection
Creatinine measurement in blood and urine is an important diagnostic test for assessing kidney health. In this study, a molecularly imprinted polymer was obtained by incorporating ...
Multiple Biomarker Responses in Female Catfish (Clarias Gariepinus) Exposed to Acetaminophen
Multiple Biomarker Responses in Female Catfish (Clarias Gariepinus) Exposed to Acetaminophen
Abstract Acetaminophen is one of the most commonly detected Analgesics and pain killer drug in freshwater environments. This study evaluated the ...
Acute Acetaminophen Overdose Is Associated with Dose‐Dependent Hypokalaemia: A Prospective Study of 331 Patients
Acute Acetaminophen Overdose Is Associated with Dose‐Dependent Hypokalaemia: A Prospective Study of 331 Patients
Abstract:  Hypokalaemia is a recognized complication of acute acetaminophen overdose. It is unclear whether this might be a pharmacological effect of acetaminophen, or due to assoc...
Molecularly imprinted polymers and their application as environmental sensors
Molecularly imprinted polymers and their application as environmental sensors
Molecularly imprinted polymers are specialty polymers with ability of selectively capturing target molecules. They show great potential to be environmental sensors for the detectio...
Boosting Oxygen Electrode Performance via a Redox-Treatment
Boosting Oxygen Electrode Performance via a Redox-Treatment
Introduction The transition to a sustainable energy system complying with climate policy targets is a huge societal challenge. “Hard to electri...
Preparation of Polyaniline Nanofibers And Experimental Study On Their Electrochemical Properties And Conductivity
Preparation of Polyaniline Nanofibers And Experimental Study On Their Electrochemical Properties And Conductivity
Abstract Among nano polyaniline materials, polyaniline nanofibers are the most important. The low conductivity and poor processability have become the biggest obstacles to ...

Back to Top