Javascript must be enabled to continue!
The Effect of Different Sterilization Methods on Polypropylene Syringes
View through CrossRef
This presents the influence of gamma irradiation on Pharmacopeia specifications, mechanical and flow parameters of polypropylene (PP) syringes. There has been significant progress in the terminal sterilization of single-use, disposable medical devices with gamma radiation sterilization due to the growing awareness of toxic residues during the ethylene oxide (EtO) sterilization. PP is a widely used polymer for the production of syringes because of its excellent mechanical and thermal properties and has expanded continuously over the last decade. Although 25 kGy was generally recommended for the gamma radiation sterilization of medical products, this radiation dose is high enough to produce substantial damage. Electron spin resonance (ESR) characteristics of irradiated syringes were also studied at normal (25 °C, 60% relative humidity) and accelerated (40 °C, 75% relative humidity) stability test conditions. It was found that the chemical and radiolytic changes and sterility assurance levels (SAL) after gamma radiation sterilization were different in PP syringes. It was shown that for two commercial syringes, E1 and E3, a SAL of 10−4 could be attained with only 10 kGy, with there being less detrimental radiation effects on E1. The differences in the radiosensitivity of the propylene syringes could be due to the different formulations and manufacturing processes. The results indicated that a commercial syringe, identified as E1 could be safely sterilized with gamma irradiation as the radicals decay over a period of days under normal conditions and quenched much faster under stability conditions. Furthermore, ESR technique could be used successfully in monitoring the radiosterilization of this material. Additionally, the confirmation and validation of the SAL doses which are below 25 kGy, will decrease the time and cost of the sterilization with less damaging effects of ionizing irradiation.
Title: The Effect of Different Sterilization Methods on Polypropylene Syringes
Description:
This presents the influence of gamma irradiation on Pharmacopeia specifications, mechanical and flow parameters of polypropylene (PP) syringes.
There has been significant progress in the terminal sterilization of single-use, disposable medical devices with gamma radiation sterilization due to the growing awareness of toxic residues during the ethylene oxide (EtO) sterilization.
PP is a widely used polymer for the production of syringes because of its excellent mechanical and thermal properties and has expanded continuously over the last decade.
Although 25 kGy was generally recommended for the gamma radiation sterilization of medical products, this radiation dose is high enough to produce substantial damage.
Electron spin resonance (ESR) characteristics of irradiated syringes were also studied at normal (25 °C, 60% relative humidity) and accelerated (40 °C, 75% relative humidity) stability test conditions.
It was found that the chemical and radiolytic changes and sterility assurance levels (SAL) after gamma radiation sterilization were different in PP syringes.
It was shown that for two commercial syringes, E1 and E3, a SAL of 10−4 could be attained with only 10 kGy, with there being less detrimental radiation effects on E1.
The differences in the radiosensitivity of the propylene syringes could be due to the different formulations and manufacturing processes.
The results indicated that a commercial syringe, identified as E1 could be safely sterilized with gamma irradiation as the radicals decay over a period of days under normal conditions and quenched much faster under stability conditions.
Furthermore, ESR technique could be used successfully in monitoring the radiosterilization of this material.
Additionally, the confirmation and validation of the SAL doses which are below 25 kGy, will decrease the time and cost of the sterilization with less damaging effects of ionizing irradiation.
Related Results
Forced Sterilization
Forced Sterilization
Photo by Renè Müller on Unsplash
INTRODUCTION
Forced sterilization of women around the globe is a human rights violation and bioethical concern. In the past, countries enacted laws...
Pregnancy after Tubal Sterilization
Pregnancy after Tubal Sterilization
Objectives: In our study, we have tried to evaluate the causative factors for sterilization failure and also to discuss preventive measures to avoid maternal morbidities and unwant...
Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures
Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures
OBJECTIVE:
To compare obstetric outcomes after failed hysteroscopic and laparoscopic sterilization.
METHODS:
This retrospe...
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
Sterilization is a critical process with wide-ranging applications in healthcare, pharmaceuticals, food production, and laboratory research. Its primary objective is the complete e...
Efficacy of air/water syringe tip sterilization
Efficacy of air/water syringe tip sterilization
AbstractBackgroundDental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilizat...
Gynecologic Outcomes After Hysteroscopic and Laparoscopic Sterilization Procedures
Gynecologic Outcomes After Hysteroscopic and Laparoscopic Sterilization Procedures
OBJECTIVE:
To compare rates of gynecologic morbidity after laparoscopic and hysteroscopic sterilization.
METHODS:
This ret...
Biocompatibility of gelatins A and B after sterilization by different methods
Biocompatibility of gelatins A and B after sterilization by different methods
Introduction: The reliable sterilization of gelatin-based hydrogels is of critical importance for the clinical application of a multitude of biomanufactured functional constructs f...
Assessing the Clinical, Economic, and Health Resource Utilization Impacts of Prefilled Syringes Versus Conventional Medication Administration Methods: Results From a Systematic Literature Review
Assessing the Clinical, Economic, and Health Resource Utilization Impacts of Prefilled Syringes Versus Conventional Medication Administration Methods: Results From a Systematic Literature Review
Objective:
The objective of this systematic review was to assess the clinical, economic, and health resource utilization outcomes associated with the use of pre...

