Javascript must be enabled to continue!
Non-Contact Magnetic Tomography Method MTM Inspection for Re-Instatement of a Decommissioned Buried Pipeline
View through CrossRef
Abstract
The Magnetic Tomography Method (MTM) has been introduced as a non-intrusive inspection technique capable of inspecting ferromagnetic materials such as carbon steel pipeline without any contact. A buried main pipeline in one of PETRONAS's operating countries that had been out of service for more than 8 years needed to be inspected prior to being re-instated. This paper discusses in detail how this innovative MTM technology was used to successfully inspect a decommissioned buried pipeline and safely re-instated the pipeline operation. The MTM inspection covered 172 kilometres of buried pipeline, including the calibration work which involved direct assessment methods. The danger degrees such as Rank 1, 2 and 3, as well as the safe operating pressures, Psafe along the entire pipeline were determined using the MTM results of Risk Factor F in accordance with MTM technical approach. Direct assessment findings were consistent with the MTM inspection findings, as the technology detected all of the anomalies discovered by the direct assessment methods. MTM inspections of decommissioned buried pipelines are proven since they are reliant on the residual self-magnetic leakage field (SMLF) in the pipeline and do not require any intrusive works. Being a non-intrusive inspection method, this technology was not affected by the low pressure & low flowrate, and no changes to the pipeline operation mode was required during the inspection. Further, this MTM inspection method was not affected by the stalled pigs inside the pipeline, as this inspection method was non-intrusive. The inspection results serve as major input to the Pipeline Integrity Management System (PIMS) to effectively manage the integrity and risk level of the pipeline.
Title: Non-Contact Magnetic Tomography Method MTM Inspection for Re-Instatement of a Decommissioned Buried Pipeline
Description:
Abstract
The Magnetic Tomography Method (MTM) has been introduced as a non-intrusive inspection technique capable of inspecting ferromagnetic materials such as carbon steel pipeline without any contact.
A buried main pipeline in one of PETRONAS's operating countries that had been out of service for more than 8 years needed to be inspected prior to being re-instated.
This paper discusses in detail how this innovative MTM technology was used to successfully inspect a decommissioned buried pipeline and safely re-instated the pipeline operation.
The MTM inspection covered 172 kilometres of buried pipeline, including the calibration work which involved direct assessment methods.
The danger degrees such as Rank 1, 2 and 3, as well as the safe operating pressures, Psafe along the entire pipeline were determined using the MTM results of Risk Factor F in accordance with MTM technical approach.
Direct assessment findings were consistent with the MTM inspection findings, as the technology detected all of the anomalies discovered by the direct assessment methods.
MTM inspections of decommissioned buried pipelines are proven since they are reliant on the residual self-magnetic leakage field (SMLF) in the pipeline and do not require any intrusive works.
Being a non-intrusive inspection method, this technology was not affected by the low pressure & low flowrate, and no changes to the pipeline operation mode was required during the inspection.
Further, this MTM inspection method was not affected by the stalled pigs inside the pipeline, as this inspection method was non-intrusive.
The inspection results serve as major input to the Pipeline Integrity Management System (PIMS) to effectively manage the integrity and risk level of the pipeline.
Related Results
Health impact assessment of mountaintop mining
Health impact assessment of mountaintop mining
Background: Mountaintop mining (MTM) is one of the most high profile environmental issues in the United States. The adverse environmental impacts of MTM have been determined after ...
Abstract 1851: Selective targeting of aberrant ETS transcription factors using uniquely modified mithramycin analogs
Abstract 1851: Selective targeting of aberrant ETS transcription factors using uniquely modified mithramycin analogs
Abstract
Background: Recent studies demonstrated that the aberrant oncogenic activity of ETS transcription factor fusions such as EWS-FLI1 and EWS-ERG in Ewing sarco...
Zero-Biasing Split Ring Resonator using Metamaterial Element for High Gain Superstrates Ultra-Wideband Antenna
Zero-Biasing Split Ring Resonator using Metamaterial Element for High Gain Superstrates Ultra-Wideband Antenna
Complex materials with artificial structures known as metamaterials (MTM) have unique properties that draw several scientists to use them in a variety of research fields. In additi...
Installation Analysis of Matterhorn Pipeline Replacement
Installation Analysis of Matterhorn Pipeline Replacement
Abstract
The paper describes the installation analysis for the Matterhorn field pipeline replacement, located in water depths between 800-ft to 1200-ft in the Gul...
Decision Support System on Pipeline Replacement of 200 kilometers Main Oil Transport Pipeline in a Very Mature Oil Block
Decision Support System on Pipeline Replacement of 200 kilometers Main Oil Transport Pipeline in a Very Mature Oil Block
Abstract
Objectives/Scope
The objectives of the research are to establish decision support system for pipeline replacement. The ...
Integrity of Buried Flexible Pipeline Using Numerical Approach
Integrity of Buried Flexible Pipeline Using Numerical Approach
Abstract
Unbonded flexible pipe is being adopted by many operators worldwide for short pipelines and where scrapping is not mandated from the perspective of service ...
Seismic Vulnerability of the Subsea Pipeline
Seismic Vulnerability of the Subsea Pipeline
Abstract
Unburied marine pipeline vulnerability under seismic impact, a new approach of investigation, and conclusion / recommendations for certain analyzed cases...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...

