Javascript must be enabled to continue!
Experimental Analysis of Different Refrigerants’ Thermal Behavior and Predicting Their Performance Parameters
View through CrossRef
This study experimentally compares thermodynamic performance of R290 and R404A refrigerants in a refrigeration system. In the first part of the paper, energy analysis of the refrigeration system was performed at various evaporator and condenser temperatures. Results revealed that R404A refrigerant caused an 18.6% increase in compressor power consumption. The highest coefficient of performance values in the system for R290 and R404A were 3.99 and 3.21, respectively. The second part of the paper includes artificial intelligence prediction studies. The pace and elastic net regression models were used to predict performance parameters. A single equation that can predict the cooling capacity and compressor power consumption of R290 and R404A simultaneously was derived. For the cooling capacity, pace regression showed mean absolute error of 0.0252 and root-mean-squared error of 0.0334, while elastic net regression indicated mean absolute error of 0.1103 and root-mean-squared error of 0.1262. It was concluded that R290 had better thermodynamic performance than R404A and the equations obtained with artificial intelligence were applicable to predict the experimental findings, regardless of which refrigerant gas was used.
American Institute of Aeronautics and Astronautics (AIAA)
Title: Experimental Analysis of Different Refrigerants’ Thermal Behavior and Predicting Their Performance Parameters
Description:
This study experimentally compares thermodynamic performance of R290 and R404A refrigerants in a refrigeration system.
In the first part of the paper, energy analysis of the refrigeration system was performed at various evaporator and condenser temperatures.
Results revealed that R404A refrigerant caused an 18.
6% increase in compressor power consumption.
The highest coefficient of performance values in the system for R290 and R404A were 3.
99 and 3.
21, respectively.
The second part of the paper includes artificial intelligence prediction studies.
The pace and elastic net regression models were used to predict performance parameters.
A single equation that can predict the cooling capacity and compressor power consumption of R290 and R404A simultaneously was derived.
For the cooling capacity, pace regression showed mean absolute error of 0.
0252 and root-mean-squared error of 0.
0334, while elastic net regression indicated mean absolute error of 0.
1103 and root-mean-squared error of 0.
1262.
It was concluded that R290 had better thermodynamic performance than R404A and the equations obtained with artificial intelligence were applicable to predict the experimental findings, regardless of which refrigerant gas was used.
Related Results
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Ecofriendly Refrigerants
Ecofriendly Refrigerants
The depletion of ozone layer and green house effects are worldwide problem. Refrigerants are part and source of depletion of ozone layer. As we using these Ecofriendly refrigerants...
A Review Paper on Natural and Synthetic Refrigerants
A Review Paper on Natural and Synthetic Refrigerants
The Montreal Protocol (1987) prohibited halogenated hydrocarbons with a high ozone depletion potential (ODP) because of their harmful effects on the ozone layer, which protects the...
PERFORMANCE OF NATURAL REFRIGERANTS IN TWO PHASE FLOW
PERFORMANCE OF NATURAL REFRIGERANTS IN TWO PHASE FLOW
The search for alternative environmentally friendly refrigerants have never been so crucial with the increasing demand for effective cooling of increasing miniaturization of our he...
Study on Flow Boiling of Refrigerants in Micro/Mini-Channels
Study on Flow Boiling of Refrigerants in Micro/Mini-Channels
Abstract
The flow boiling heat transfer in micro/mini-channels is encountered in many compact heat exchangers such as the once-through steam generator in nuclear rea...
Comparison of Subcooling Effect of Water as a Refrigerant With the Current Refrigerants
Comparison of Subcooling Effect of Water as a Refrigerant With the Current Refrigerants
The performance comparison of water as a refrigerant (R718) with some prevailing refrigerants including R717, R290, R134a, R12, R22, and R152a is presented. A computer program simu...
Selection of optimal fluid for refrigeration cycles
Selection of optimal fluid for refrigeration cycles
Refrigeration and air-conditioning play an important role in our life and industrial applications. They have great impact on our life. They have also contributed to the world’s maj...

