Javascript must be enabled to continue!
E-038 Acute histologic changes observed in swine arteries treated with a mechanical thrombectomy device: Abstract E-038 Figure 1
View through CrossRef
Background and purposeEffectiveness of currently used mechanical thrombectomy devices has been evaluated using animal models mainly based upon the angiographical data analysis. However very little has been described about the histologic changes observed in the arteries treated with mechanical thrombectomy devices. The purpose of this study is to evaluate acute arterial histologic changes induced by mechanical thrombectomy using a dedicated swine stroke model.Materials and MethodsA total of eight Superficial Cervical Arteries in four swine were occluded with experimental thrombus and treated using the Merci Clot Retrieval System®. Each treated artery was harvested immediately after the procedure and histologic analysis of each arterial sample was performed. Four untreated Superficial Cervical Arteries were used as controls.ResultsA total of 24 attempts at clot retrieval were made. The average number of retrieval attempts per artery was three. Circumferential intimal denudation and separation of smooth muscle layers in the tunica media were seen in all samples. The intimal denudation was seen regardless of the number of retrieval attempts. A minor sub-intimal dissection was seen in one artery. Arterial perforation with sub-adventitial hematoma was seen in two arteries and these findings were associated with microwire/microcatheter navigation rather than the use of the clot retrieval device.ConclusionMinor histologic changes including intimal denudation and separation of smooth muscle layers in tunica media were seen in every artery treated by mechanical thrombectomy. Two arteries that showed major histologic change (sub-adventitial hematoma) were both associated with microwire/catheter navigation rather than the use of the clot retrieval device. It is possible that major arterial injury (eg vessel perforation) during the mechanical thrombectomy is more likely to be associated with microcatheter/microwire navigation rather than clot retrieval itself. This animal model may be useful in the preclinical safety evaluation of the mechanical thrombectomy devices.Competing interestsI Yuki: None. I Kan: None. A Golshan: None. H Vinters: None. R Kim: None. N Yin: None. G Duckwiler: Concentric Medical. F Vinuela: None. Y Murayama: None. F Vinuela: None.Abstract E-038 Figure 1
Title: E-038 Acute histologic changes observed in swine arteries treated with a mechanical thrombectomy device: Abstract E-038 Figure 1
Description:
Background and purposeEffectiveness of currently used mechanical thrombectomy devices has been evaluated using animal models mainly based upon the angiographical data analysis.
However very little has been described about the histologic changes observed in the arteries treated with mechanical thrombectomy devices.
The purpose of this study is to evaluate acute arterial histologic changes induced by mechanical thrombectomy using a dedicated swine stroke model.
Materials and MethodsA total of eight Superficial Cervical Arteries in four swine were occluded with experimental thrombus and treated using the Merci Clot Retrieval System®.
Each treated artery was harvested immediately after the procedure and histologic analysis of each arterial sample was performed.
Four untreated Superficial Cervical Arteries were used as controls.
ResultsA total of 24 attempts at clot retrieval were made.
The average number of retrieval attempts per artery was three.
Circumferential intimal denudation and separation of smooth muscle layers in the tunica media were seen in all samples.
The intimal denudation was seen regardless of the number of retrieval attempts.
A minor sub-intimal dissection was seen in one artery.
Arterial perforation with sub-adventitial hematoma was seen in two arteries and these findings were associated with microwire/microcatheter navigation rather than the use of the clot retrieval device.
ConclusionMinor histologic changes including intimal denudation and separation of smooth muscle layers in tunica media were seen in every artery treated by mechanical thrombectomy.
Two arteries that showed major histologic change (sub-adventitial hematoma) were both associated with microwire/catheter navigation rather than the use of the clot retrieval device.
It is possible that major arterial injury (eg vessel perforation) during the mechanical thrombectomy is more likely to be associated with microcatheter/microwire navigation rather than clot retrieval itself.
This animal model may be useful in the preclinical safety evaluation of the mechanical thrombectomy devices.
Competing interestsI Yuki: None.
I Kan: None.
A Golshan: None.
H Vinters: None.
R Kim: None.
N Yin: None.
G Duckwiler: Concentric Medical.
F Vinuela: None.
Y Murayama: None.
F Vinuela: None.
Abstract E-038 Figure 1.
Related Results
Aspiration thrombectomy versus stent retriever thrombectomy as a first-line approach for cardiogenic cerebral embolism and cryptogenic stroke in large vessels of the anterior circulation
Aspiration thrombectomy versus stent retriever thrombectomy as a first-line approach for cardiogenic cerebral embolism and cryptogenic stroke in large vessels of the anterior circulation
SubjectThis study aims to compare the clinical efficacy of aspiration thrombectomy and stent retriever thrombectomy as first-line approaches for anterior circulation large vessel c...
THE PIG AS A BIOMEDICAL MODEL: HOW THE NATIONAL SWINE RESOURCE AND RESEARCH CENTER CAN HELP YOU
THE PIG AS A BIOMEDICAL MODEL: HOW THE NATIONAL SWINE RESOURCE AND RESEARCH CENTER CAN HELP YOU
Swine are an excellent large animal model for human health and disease because their size and physiology are similar to humans, and the progression of many diseases, such as cardio...
Knowledge and practices related to swine flu in school students of Bhavnagar, Gujarat
Knowledge and practices related to swine flu in school students of Bhavnagar, Gujarat
Context: Swine Flu caused by Influenza virus of H1N1 strain is a highly infectious respiratory disease. Knowledge and awareness among the community regarding the containment of spr...
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
Background
The radial artery has become a widely used approach for coronary angiography and intervention in patients, and the ulnar artery is another approach for...
Abstract Number ‐ 63: A swine model to simulate the mechanism of aspiration thrombectomy.
Abstract Number ‐ 63: A swine model to simulate the mechanism of aspiration thrombectomy.
Introduction
Aspiration thrombectomy is an effective technique to recanalize large vessel occlusions (LVO) in stroke patients and has become one of the major techniques...
Swine flu awareness in pregnancy
Swine flu awareness in pregnancy
Background: Swine influenza outbreaks are common in pigs year-round and infection in humans is a result of close contact with infected animals. Understanding the perception of the ...
Higher-Quality Data Collection Is Critical to Establish the Safety and Efficacy of Pediatric Mechanical Thrombectomy
Higher-Quality Data Collection Is Critical to Establish the Safety and Efficacy of Pediatric Mechanical Thrombectomy
Background and Purpose:
Because children often have lifelong morbidity after stroke, there is considerable enthusiasm to pursue mechanical thrombectomy in child...
SWINE INFLUENZA
SWINE INFLUENZA
1. It has been possible to demonstrate, in Berkefeld filtrates of infectious material from experimental cases of swine influenza, a virus which when administered intranasally to su...

