Effects of Different Voltage Sag Types on Induction Motor
View through CrossRef
This paper analyzes effects caused by voltage sag types A, B, C and D on induction motor based on experimental test. The effect can be investigated in term the current peaks and speed variation. The magnitudes depend on magnitude of sag and duration, voltage sag types, during and recovery voltage sag. Several of voltage sag characteristics have been conducted in different magnitude, duration and sag types. The results show that the current peaks generated reach more than 4 times of normal current and it was achieved at recovery voltage instant. Sag magnitude has great influence on the current peak but sag duration is not significantly. Type A voltage sag only can cause the motor stop running and it was achieved when it was subjected to sag magnitude of 10% and 6s in duration. The motor stops running in shorter duration when it was subjected to interruption with sag duration of 4s. Therefore voltage sag of type A lead to more severe on induction motor if compared with other sag type. This is according to number of phase that experience sag. The magnitude and duration of voltage sags have influenced significantly on the motor speed only for low sag magnitude and long sag duration.
Trans Tech Publications, Ltd.
Title: Effects of Different Voltage Sag Types on Induction Motor
Description:
This paper analyzes effects caused by voltage sag types A, B, C and D on induction motor based on experimental test.
The effect can be investigated in term the current peaks and speed variation.
The magnitudes depend on magnitude of sag and duration, voltage sag types, during and recovery voltage sag.
Several of voltage sag characteristics have been conducted in different magnitude, duration and sag types.
The results show that the current peaks generated reach more than 4 times of normal current and it was achieved at recovery voltage instant.
Sag magnitude has great influence on the current peak but sag duration is not significantly.
Type A voltage sag only can cause the motor stop running and it was achieved when it was subjected to sag magnitude of 10% and 6s in duration.
The motor stops running in shorter duration when it was subjected to interruption with sag duration of 4s.
Therefore voltage sag of type A lead to more severe on induction motor if compared with other sag type.
This is according to number of phase that experience sag.
The magnitude and duration of voltage sags have influenced significantly on the motor speed only for low sag magnitude and long sag duration.
Related Results
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Induction motor is widely used due to advantages in terms of performance, size, maintenance and efficiency compared to dc motor. Induction motor is either Scalar Controlled or Vect...
Comparative Analysis between Dynamic Voltage Restorer and PWM-Switched Autotransformer in Voltage Sag Mitigation
Comparative Analysis between Dynamic Voltage Restorer and PWM-Switched Autotransformer in Voltage Sag Mitigation
This research aims to address the problem of voltage sag, which is a significant power quality issue in power systems. Voltage sag can lead to power transmission and distribution l...
Experimental Study on the Phenomenon of Barite Sag
Experimental Study on the Phenomenon of Barite Sag
Abstract
Increasing global energy demand and diminishing petroleum reserves have continually elevated the significance of extended reach deepwater drilling. The e...
Self-Supervised Voltage Sag Source Identification Method Based on CNN
Self-Supervised Voltage Sag Source Identification Method Based on CNN
A self-supervised voltage sag source identification method based on a convolution neural network is proposed in this study. In addition, a self-supervised CNN (Convolutional Neural...
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Background:
Data suggests that the presence of measurable residual disease (MRD) at the time of transplant for AML portends a poor prognosis. The timing of MRD asses...
Clustering Analysis of Voltage Sag Events Based on Waveform Matching
Clustering Analysis of Voltage Sag Events Based on Waveform Matching
Voltage sags are a serious problem within power supplies, which pose threats to both residential electricity and industrial manufacturing. Since any one sag may be recorded by mult...
Design and Control of Modular Multilevel Converter for Voltage Sag Mitigation
Design and Control of Modular Multilevel Converter for Voltage Sag Mitigation
Voltage sag in a power system is an unavoidable power quality issue, and it is also an urgent concern of sensitive industrial users. To ensure the power quality demand and economic...
Sağ Siyasetin Ontolojik Grameri
Sağ Siyasetin Ontolojik Grameri
Sağ siyasetin ontolojik gramerini anlamayı ve anlamlandırmayı amaçlayan bu makalede öncelikle ontolojik gramer kavramı üzerinde durulacaktır. Ontolojik gramer Martin Heidegger’in ...