Javascript must be enabled to continue!
Discrimination of Three-Phase Three-Limb Transformer Inrush Current Based on Characteristics of Instantaneous Excitation Inductances
View through CrossRef
Existing methods utilizing excitation inductances to discriminate inrush current and internal fault of transformer are all derived from the singe-phase transformer circuit model, yet there are no discussions considering the widely used three-phase three-limb transformers. In view of this question, the mathematical model of three-phase three-limb transformer based on the characteristics of its magnetic equivalent circuit is established, through which the excitation inductances of the three-phase three-limb transformer can be calculated. The calculated excitation inductances have definite physical meanings and can reflect the saturation state of the transformer core under inrush condition. Analysis of the circuit model demonstrates that the delta circulating current is not the excitation current of three-phase three-limb transformer, so the proposed method can be used to the transformers with delta connection directly. The proposed method has been verified by electromagnetic transients program including direct current (EMTDC) simulations, simulation results show that the calculated excitation inductances have different characteristics under inrush and internal fault conditions, and can be applied to identify the inrush current of three-phase three-limb transformer.
Trans Tech Publications, Ltd.
Title: Discrimination of Three-Phase Three-Limb Transformer Inrush Current Based on Characteristics of Instantaneous Excitation Inductances
Description:
Existing methods utilizing excitation inductances to discriminate inrush current and internal fault of transformer are all derived from the singe-phase transformer circuit model, yet there are no discussions considering the widely used three-phase three-limb transformers.
In view of this question, the mathematical model of three-phase three-limb transformer based on the characteristics of its magnetic equivalent circuit is established, through which the excitation inductances of the three-phase three-limb transformer can be calculated.
The calculated excitation inductances have definite physical meanings and can reflect the saturation state of the transformer core under inrush condition.
Analysis of the circuit model demonstrates that the delta circulating current is not the excitation current of three-phase three-limb transformer, so the proposed method can be used to the transformers with delta connection directly.
The proposed method has been verified by electromagnetic transients program including direct current (EMTDC) simulations, simulation results show that the calculated excitation inductances have different characteristics under inrush and internal fault conditions, and can be applied to identify the inrush current of three-phase three-limb transformer.
Related Results
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Comparison and Analysis of Magnetizing Inrush and Fault Condition for Power Transformer
Comparison and Analysis of Magnetizing Inrush and Fault Condition for Power Transformer
This paper presents the second harmonics present in the primary current of a power transformer at different conditions using Fast Fourier Transform and Total Harmonic Distortion te...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Leakage Inductances Influences of Integrated-Transformer in Input-Series Flyback Converter
Leakage Inductances Influences of Integrated-Transformer in Input-Series Flyback Converter
In this paper, the leakage inductances influences of integrated-transformer are investigated for an input-series flyback converter, in which each input-series circuit is based on t...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...