Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Hangar fire detection alarm with algorithm for extinguisher

View through CrossRef
A fire alarm is a high-performance system that detects smoke, heat or flames and actuates fire suppression system, for the protection of lives and property. It is employed in aircraft hangars for the protection of aircraft, personnel as well as the hangar structure. The need for a fire alarm in a hangar with algorithm for extinguishers cannot be overemphasized. The structure of the hangar building, type of aircraft housed in the hangar and activities carried out at the hangar such as inspections, overhauls and modifications of aircraft, determine the type of fire alarm to be used, whether it should be automatic or manual [2]. The detection employed, be it smoke detection, heat sensing or both and the process of extinguishing in the face of a fire threat or hazard is equally important. The effectiveness of the alarm is dependent on genuine alerts and not false alarm triggers, hence in this research paper, the employment of intelligent detection using comparators in programmed IC, the Micro-controller, was interfaced with a 555 Timer, a multi-vibrator for generating aural sound for alarm, LCD Display for indicated readings as well as algorithm for extinguishing using water or foam via sprinklers. The basic work started with a block diagram representation, thereafter, individual subsystems, which form the building blocks were analyzed and the components parts identified. A circuit diagram for the project was analyzed and built using Proteus. This was simulated and found to be achievable, hence a program was written in C++ for the micro-controller using Arduino Language known as the source code. The results show hangar fire detection alarm with algorithm for extinguishing and was investigated as an effective means of suppressing fire threat in the hangar [4].
Title: Hangar fire detection alarm with algorithm for extinguisher
Description:
A fire alarm is a high-performance system that detects smoke, heat or flames and actuates fire suppression system, for the protection of lives and property.
It is employed in aircraft hangars for the protection of aircraft, personnel as well as the hangar structure.
The need for a fire alarm in a hangar with algorithm for extinguishers cannot be overemphasized.
The structure of the hangar building, type of aircraft housed in the hangar and activities carried out at the hangar such as inspections, overhauls and modifications of aircraft, determine the type of fire alarm to be used, whether it should be automatic or manual [2].
The detection employed, be it smoke detection, heat sensing or both and the process of extinguishing in the face of a fire threat or hazard is equally important.
The effectiveness of the alarm is dependent on genuine alerts and not false alarm triggers, hence in this research paper, the employment of intelligent detection using comparators in programmed IC, the Micro-controller, was interfaced with a 555 Timer, a multi-vibrator for generating aural sound for alarm, LCD Display for indicated readings as well as algorithm for extinguishing using water or foam via sprinklers.
The basic work started with a block diagram representation, thereafter, individual subsystems, which form the building blocks were analyzed and the components parts identified.
A circuit diagram for the project was analyzed and built using Proteus.
This was simulated and found to be achievable, hence a program was written in C++ for the micro-controller using Arduino Language known as the source code.
The results show hangar fire detection alarm with algorithm for extinguishing and was investigated as an effective means of suppressing fire threat in the hangar [4].

Related Results

Animal Alarm Calls
Animal Alarm Calls
Alarm calls are broadly defined as calls occurring in a predator context. Alarm calls have been the subject of intense scrutiny in animal communication research, as they are releva...
Clinical Alarm Awareness, Management Challenges, and Alarm Fatigue Among ICU Nurses
Clinical Alarm Awareness, Management Challenges, and Alarm Fatigue Among ICU Nurses
Abstract Background Clinical alarms play a crucial role in ensuring patient safety in intensive care units (ICUs). However, excessive alarms and ineffective alarm managemen...
Optimizing Multimodal Alarm Design for Attention Allocation in Discrete Monitoring Tasks
Optimizing Multimodal Alarm Design for Attention Allocation in Discrete Monitoring Tasks
Discrete monitoring tasks are common in scenarios such as flight missions, air traffic control, nuclear power plant monitoring, and clinical healthcare. In these tasks, operators p...
Implementing an Efficient Alarm Management System Using Cutting-Edge Methods
Implementing an Efficient Alarm Management System Using Cutting-Edge Methods
Abstract The objective of this paper is to provide new, effective and innovative methods and best practices for an efficient implementation of the alarm management s...
Detecting False Alarms by Analyzing Alarm-Context Information: Algorithm Development and Validation (Preprint)
Detecting False Alarms by Analyzing Alarm-Context Information: Algorithm Development and Validation (Preprint)
BACKGROUND Although alarm safety is a critical issue that needs to be addressed to improve patient care, hospitals have not given serious consideration abou...
Alarm-Calling And Response Behaviors Of The Black-Tailed Prairie Dog In Kansas
Alarm-Calling And Response Behaviors Of The Black-Tailed Prairie Dog In Kansas
Prairie dogs (Cynomys spp.) use alarm calls to warn offspring and other kin of predatory threats. Dialects occur when vocalizations contain consistent differences among populations...
Üst gis endoskopi yapılacak hastalarda alarm semptom varlığı ile organik patoloji arasındaki prediksiyon çalışması
Üst gis endoskopi yapılacak hastalarda alarm semptom varlığı ile organik patoloji arasındaki prediksiyon çalışması
Giriş ve Amaç: Dispepsili genç hastalarda alarm semptomlarının olmaması malignite yokluğuna dair güvenilir bir gösterge olarak kabul edilmektedir. Ancak alarm semptomla...

Back to Top