Javascript must be enabled to continue!
SU‐E‐T‐686: A New Plan Quality Index for Dose‐Painting Radiotherapy
View through CrossRef
Purpose: In dose‐painting by numbers, conventional plan quality indices such as homogeneity index (HI) and dose‐standard‐deviation (STD) have limitations in application. This study aims to introduce new indices for evaluating treatment plans of this radiotherapy technique. Methods: Deviation‐from‐prescription‐index (DFPI) was formulated as the volume‐weighted average of the deviation between prescription dose and planned dose. Two sub‐indices, index‐of‐hotness (IOH) and index‐of‐coldness (IOC) were also defined specifically for selected voxels of which planned dose was higher and lower than the prescribed dose, respectively. The new indices were first tested for 9 IMRT/VMAT plans having 3 different dose prescription levels. For comparison purpose, 4 conventional indices (three types of HI and STD) and difference between V98 and V110 [V110 + (100− V98)] were calculated in each prescription region, and then averaged. Using the Spearman rank correlation test, the relationship was investigated between the DFPI‐based ranks and the composite ranks based on all of 5 conventional indices. The new indices were also evaluated in 9 theoretically‐generated plans having a continuously varying function of dose prescription where the conventional indices are not applicable. Results: The plan quality ranks according to DFPI were found to be highly correlated with that from the composite of conventional indices (correlation coefficient = 0.95, where 1 means perfect correlation). It was also demonstrated that the new indices are applicable to dose painted plans in a continuously varying dose prescription. Conclusion: It was shown that the new plan quality indices formulated with voxel‐based prescription dose can be appropriately used for dose‐painting radiotherapy. The indices allow for a single‐value evaluation regardless of the number of prescribed dose levels, which cannot be achieved using the conventional indices.
Title: SU‐E‐T‐686: A New Plan Quality Index for Dose‐Painting Radiotherapy
Description:
Purpose: In dose‐painting by numbers, conventional plan quality indices such as homogeneity index (HI) and dose‐standard‐deviation (STD) have limitations in application.
This study aims to introduce new indices for evaluating treatment plans of this radiotherapy technique.
Methods: Deviation‐from‐prescription‐index (DFPI) was formulated as the volume‐weighted average of the deviation between prescription dose and planned dose.
Two sub‐indices, index‐of‐hotness (IOH) and index‐of‐coldness (IOC) were also defined specifically for selected voxels of which planned dose was higher and lower than the prescribed dose, respectively.
The new indices were first tested for 9 IMRT/VMAT plans having 3 different dose prescription levels.
For comparison purpose, 4 conventional indices (three types of HI and STD) and difference between V98 and V110 [V110 + (100− V98)] were calculated in each prescription region, and then averaged.
Using the Spearman rank correlation test, the relationship was investigated between the DFPI‐based ranks and the composite ranks based on all of 5 conventional indices.
The new indices were also evaluated in 9 theoretically‐generated plans having a continuously varying function of dose prescription where the conventional indices are not applicable.
Results: The plan quality ranks according to DFPI were found to be highly correlated with that from the composite of conventional indices (correlation coefficient = 0.
95, where 1 means perfect correlation).
It was also demonstrated that the new indices are applicable to dose painted plans in a continuously varying dose prescription.
Conclusion: It was shown that the new plan quality indices formulated with voxel‐based prescription dose can be appropriately used for dose‐painting radiotherapy.
The indices allow for a single‐value evaluation regardless of the number of prescribed dose levels, which cannot be achieved using the conventional indices.
Related Results
Clinical and 18F-FDG PET/CT Imaging Characteristics of Post-radiotherapy Sacral Insufficiency Fractures in Cervical Cancer Patients
Clinical and 18F-FDG PET/CT Imaging Characteristics of Post-radiotherapy Sacral Insufficiency Fractures in Cervical Cancer Patients
Introduction:
Sacral Insufficiency Fractures (SIFs) are a common yet frequently misdiagnosed late complication following pelvic radiotherapy for cervical
cancer...
Dosimetric comparisons of intensity‐modulated radiation therapy and three‐dimensional conformal radiation therapy for left‐sided breast cancer after radical surgery
Dosimetric comparisons of intensity‐modulated radiation therapy and three‐dimensional conformal radiation therapy for left‐sided breast cancer after radical surgery
AbstractObjectivePostoperative radiotherapy for breast cancer is an effective way to control tumor recurrence; however, there are advantages and disadvantages to different radiothe...
Hemostatic radiotherapy in cervical cancer: experience at the Dalal Jamm hospital radiotherapy department
Hemostatic radiotherapy in cervical cancer: experience at the Dalal Jamm hospital radiotherapy department
Introduction: Radiotherapy is crucial in controlling life-threatening bleeding associated with advanced cervical cancer. The objective was to describe our experience in managing se...
Current Developments in Radiotherapy Quality Control Methods
Current Developments in Radiotherapy Quality Control Methods
Quality control is of critical importance to ensure the accurate and reliable implementation of treatment in radiotherapy. Radiotherapy is a primary method of treating diseases suc...
Radiotherapy refusal in breast cancer with breast-conserving surgery
Radiotherapy refusal in breast cancer with breast-conserving surgery
Abstract
Background
Although radiotherapy after breast-conserving surgery has been the standard treatment for breast cancer, some people still refus...
Common oral conditions associated with post-radiotherapy patients in Africa
Common oral conditions associated with post-radiotherapy patients in Africa
Radiotherapy involves the use of high-energy radiation to shrink and or kill cancer cells, thus preventing the cells from growing, dividing, and spreading. Oral conditions associat...
P-598 Dose accuracy of the follitropin-alfa, follitropin-alfa/lutropin-alfa and choriogonadotropin-alfa pen injectors used for fertility treatment
P-598 Dose accuracy of the follitropin-alfa, follitropin-alfa/lutropin-alfa and choriogonadotropin-alfa pen injectors used for fertility treatment
Abstract
Study question
Do the Merck family of fertility pen injectors (follitropin-alfa, follitropin-alfa/lutropin-alfa, chorio...
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
AbstractPurposeRadiochromic films are versatile 2D dosimeters with high‐resolution and near tissue equivalence. To assure high precision and accuracy, a time‐consuming calibration ...

