Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Replacement of Sealed Nickel-Cadmium Batteries on EA-6B Aircraft with Valve Regulated Lead-Acid Batteries

View through CrossRef
<div class="htmlview paragraph">This paper will summarize the details of replacing the EA-6B Sealed Nickel-Cadmium (SNC) batteries in an effort to reduce battery maintenance and battery maintenance costs. A flight evaluation program is presently underway at two locations to validate the proposed change from SNC batteries to Valve Regulated Lead-Acid (VRLA) batteries. The EA-6B aircraft currently uses two 26-volt SNC batteries, military part number (MIL PN) D8565/1-1, and one 24-volt SNC battery, part number MS17334-2. The SNC batteries are scheduled for maintenance every 112 days, which requires removal and replacement of the batteries at the O-level and battery maintenance at the I-level (battery shop). A load check is required every 28 days on the aircraft in accordance with the Maintenance Requirement Card (MRC).</div> <div class="htmlview paragraph">Under the sponsorship of the Aging Aircraft IPT (AAIPT), Naval Air Systems Command (NAVAIR 4.4.5.2) and the Crane Division, Naval Surface Warfare Center (NSWC Crane) have identified VRLA batteries as possible replacements for the SNC batteries. The proposed replacement battery, MIL PN D8565/1-2 is a direct form, fit, and function replacement for the D8565/1-1 SNC battery. The proposed replacement battery, MIL PN D8565/17-1, is a direct form, fit, and function replacement for the MS17334-2 SNC battery. It is presently planned that the VRLA batteries will have a one-year inspection period and a replacement cycle of three years. Flight testing of the VRLA battery, MIL PN D8565/1-2, began in early February 2006 and flight testing of VRLA battery, MIL PN D8565/17-1, commenced in early July 2006.</div>
Title: Replacement of Sealed Nickel-Cadmium Batteries on EA-6B Aircraft with Valve Regulated Lead-Acid Batteries
Description:
<div class="htmlview paragraph">This paper will summarize the details of replacing the EA-6B Sealed Nickel-Cadmium (SNC) batteries in an effort to reduce battery maintenance and battery maintenance costs.
A flight evaluation program is presently underway at two locations to validate the proposed change from SNC batteries to Valve Regulated Lead-Acid (VRLA) batteries.
The EA-6B aircraft currently uses two 26-volt SNC batteries, military part number (MIL PN) D8565/1-1, and one 24-volt SNC battery, part number MS17334-2.
The SNC batteries are scheduled for maintenance every 112 days, which requires removal and replacement of the batteries at the O-level and battery maintenance at the I-level (battery shop).
A load check is required every 28 days on the aircraft in accordance with the Maintenance Requirement Card (MRC).
</div> <div class="htmlview paragraph">Under the sponsorship of the Aging Aircraft IPT (AAIPT), Naval Air Systems Command (NAVAIR 4.
4.
5.
2) and the Crane Division, Naval Surface Warfare Center (NSWC Crane) have identified VRLA batteries as possible replacements for the SNC batteries.
The proposed replacement battery, MIL PN D8565/1-2 is a direct form, fit, and function replacement for the D8565/1-1 SNC battery.
The proposed replacement battery, MIL PN D8565/17-1, is a direct form, fit, and function replacement for the MS17334-2 SNC battery.
It is presently planned that the VRLA batteries will have a one-year inspection period and a replacement cycle of three years.
Flight testing of the VRLA battery, MIL PN D8565/1-2, began in early February 2006 and flight testing of VRLA battery, MIL PN D8565/17-1, commenced in early July 2006.
</div>.

Related Results

An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
American Institute of Mining, Metallurgical, and Petroleum Engineers, Inc. Abstract A surface-controlled subsurface safety valve...
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Objective: To compare the heart valve circumference before and after 10% formalin fixation. Materials and Methods: The study analyzed 63 Thai human cadaveric hearts. Each heart val...
Kolaviron, A Flavonoid From Garcinia Kola Seeds, Ameliorates Experimental Colitis In Rats Exposed To Cadmium
Kolaviron, A Flavonoid From Garcinia Kola Seeds, Ameliorates Experimental Colitis In Rats Exposed To Cadmium
Cadmium has been shown to potentiate experimental ulcers in laboratory animals. Its ability to predispose humans to ulcerative colitis has also been postulated. Polyphenols and fla...
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
The Critical Role of Presettable and Expandable Artificial Surgical Valves in the Lifetime Management of Valvular Heart Disease
With the trend of younger patients undergoing surgical valve replacement and increased life expectancy, how to account for subsequent therapies during the initial valve replacement...
Electrochemistry of Cadmium
Electrochemistry of Cadmium
Abstract The sections in this article are Double‐layer Properties of Cadmium Electrodes Electroche...
Reciprocating compressor valve damage estimation under varying speeds through the acoustic emission technique
Reciprocating compressor valve damage estimation under varying speeds through the acoustic emission technique
Purpose The purpose of this paper is to examine the effect of reciprocating compressor speeds and valve conditions on the roor-mean-square (RMS) value of burst acoustic emission (A...
Cadmium Contamination, Bioavailability, Uptake Mechanism and Remediation Strategies in Soil-Plant-Environment System: a Critical Review
Cadmium Contamination, Bioavailability, Uptake Mechanism and Remediation Strategies in Soil-Plant-Environment System: a Critical Review
Background: Cadmium contamination is becoming an important issue globally due to its high toxicity and carcinogenicity, leading to detrimental effects on both environmental and hum...

Back to Top