Timing techniques with picosecond-order accuracy for novel gaseous detectors
View through CrossRef
Abstract
A simulation model is developed to train Artificial Neural Networks (ANN), for precise timing of PICOSEC Micromegas detector signals. The aim is to develop fast, online timing algorithms as well as minimising the information to be saved during data acquisition. PICOSEC waveforms were collected and digitised by a fast oscilloscope during a femtosecond-laser test beam run. A data set comprising waveforms collected with attenuated laser beam intensity, eradicating the emission of more than one photoelectron per light pulse from the PICOSEC photocathode, was utilised by a simulation algorithm to generate waveforms to train an ANN. A second data set of multi-photoelectron waveforms was used to evaluate the ANN performance in determining the PICOSEC signal arrival time, relative to a fast photodiode time-reference. The ANN timing performance is the same as the results of a full offline signal processing, achieving a timing precision of 18.3 ± 0.6 ps.
Title: Timing techniques with picosecond-order accuracy for novel gaseous detectors
Description:
Abstract
A simulation model is developed to train Artificial Neural Networks (ANN), for precise timing of PICOSEC Micromegas detector signals.
The aim is to develop fast, online timing algorithms as well as minimising the information to be saved during data acquisition.
PICOSEC waveforms were collected and digitised by a fast oscilloscope during a femtosecond-laser test beam run.
A data set comprising waveforms collected with attenuated laser beam intensity, eradicating the emission of more than one photoelectron per light pulse from the PICOSEC photocathode, was utilised by a simulation algorithm to generate waveforms to train an ANN.
A second data set of multi-photoelectron waveforms was used to evaluate the ANN performance in determining the PICOSEC signal arrival time, relative to a fast photodiode time-reference.
The ANN timing performance is the same as the results of a full offline signal processing, achieving a timing precision of 18.
3 ± 0.
6 ps.
Related Results
Histological investigation of picosecond laser-toning and fractional laser therapy
Histological investigation of picosecond laser-toning and fractional laser therapy
Background and Aims: Rejuvenation therapy using picosecond pulse laser and picosecond pulsed fractional therapy with a fractional lens have been performed with clinical effects eva...
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Abstract
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast
gaseous detector concept that achieves picosecond-level timing. It
couple...
Research of the navigation accuracy for the X-ray pulsar navigation system
Research of the navigation accuracy for the X-ray pulsar navigation system
In order to improve the navigation accuracy of the X-ray pulsar navigation system, in this paper we propose a constant fraction timing method based on the low-pass filter to measur...
Abstract 1656: Quantifying task performance with photon-processing detectors
Abstract 1656: Quantifying task performance with photon-processing detectors
Abstract
Purpose. To estimate task performance (e.g., the ability to correctly detect a small lesion in a normal tissue) when the imaging system uses a new class of ...
Circadian meal timing is heritable and associated with insulin sensitivity
Circadian meal timing is heritable and associated with insulin sensitivity
Abstract
Background
Although the contribution of the circadian clock to metabolic regulation is widely recognized, the role of ...
Effects of the Multilayer Structure on the Responsivity of Pyroelectric Thin Film Detectors
Effects of the Multilayer Structure on the Responsivity of Pyroelectric Thin Film Detectors
AbstractPyroelectric thin film detectors have advantages of wavelength independent sensitivity, room temperature operation and direct incorporation with integrated circuit amplifie...
Diurnal variations of total mercury, reactive mercury, and dissolved gaseous mercury concentrations and water/air mercury flux in warm and cold seasons from freshwaters of southwestern China
Diurnal variations of total mercury, reactive mercury, and dissolved gaseous mercury concentrations and water/air mercury flux in warm and cold seasons from freshwaters of southwestern China
Abstract
Diurnal variations of water total Hg, reactive Hg, and dissolved gaseous Hg concentrations and mercury flux were moni...
Energy Calibration of Scintillator Detectors in Different Neutron Diagnostic System on Tokamak
Energy Calibration of Scintillator Detectors in Different Neutron Diagnostic System on Tokamak
The purpose of tokamak plasma diagnostics is to provide the necessary parameters for device protection, operation, and maintenance. It can also supply parameters for fusion physics...