Javascript must be enabled to continue!
Respiratory rate detection by a time-based measurement system
View through CrossRef
This paper proposes a system that converts a time-modulated signal from a resistive sensor into a digital signal with the goal to estimate the respiratory rate of a subject. To detect breathing, a known method based on a nasal thermistor, which detects temperature changes near the nostrils, is used. In this work, the thermistor mounted in a Wheatstone bridge, forms a RC circuit which is connected directly to a microcontroller, without using any analog circuit or analog-digital converter. Thus, whenever the subject breathes, it causes a fractional change in resistance x (Δ R/R0) on the thermistor, and this produces a time-modulated signal that is directly digitized with the microcontroller. Measurements were made on 23 volunteers, obtaining changes of x > 0.01. The temperature resolution was 0.2 °C, and the time response was 0.8 s, mainly limited by the thermistor properties; these features were enough to obtain a well-defined waveform of the breathing, from which was easy to estimate the respiratory rate by a compact, low cost and low power consumption system. Unlike interface circuits based on the voltage or current amplitude, with this kind of interface, the self-heating of the sensor is avoided since the thermistor does not require any voltage or bias current.
Title: Respiratory rate detection by a time-based measurement system
Description:
This paper proposes a system that converts a time-modulated signal from a resistive sensor into a digital signal with the goal to estimate the respiratory rate of a subject.
To detect breathing, a known method based on a nasal thermistor, which detects temperature changes near the nostrils, is used.
In this work, the thermistor mounted in a Wheatstone bridge, forms a RC circuit which is connected directly to a microcontroller, without using any analog circuit or analog-digital converter.
Thus, whenever the subject breathes, it causes a fractional change in resistance x (Δ R/R0) on the thermistor, and this produces a time-modulated signal that is directly digitized with the microcontroller.
Measurements were made on 23 volunteers, obtaining changes of x > 0.
01.
The temperature resolution was 0.
2 °C, and the time response was 0.
8 s, mainly limited by the thermistor properties; these features were enough to obtain a well-defined waveform of the breathing, from which was easy to estimate the respiratory rate by a compact, low cost and low power consumption system.
Unlike interface circuits based on the voltage or current amplitude, with this kind of interface, the self-heating of the sensor is avoided since the thermistor does not require any voltage or bias current.
Related Results
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
BACKGROUND
Suicide is a complex, serious and multifaceted public health issue that poses significant challenges to societies worldwide. In fact, it represen...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
With the advantages of high precision and great environmental adaptability, laser heterodyne interferometry has been successfullyused in some areas, such as measuring distance and ...
Pilarowski–Bjornsson Syndrome with Congenital Heart Defect: A Case Report and Literature Review
Pilarowski–Bjornsson Syndrome with Congenital Heart Defect: A Case Report and Literature Review
Abstract
Introduction
Pilarowski–Bjornsson syndrome (PILBOS) is a rare autosomal dominant neurodevelopmental disorder caused by heterozygous variants in chromodomain helicase DNA-b...
Screening Sleep Disordered Breathing with Noncontact Measurement in a Clinical Site
Screening Sleep Disordered Breathing with Noncontact Measurement in a Clinical Site
[abstFig src='/00290002/06.jpg' width='300' text='Respiratory rate from simulator and Kinect' ]<span class=”bold”>Background and purpose:</span>It has been considered t...
Dynamic calibration method for track geometry measurement system-a case study in China
Dynamic calibration method for track geometry measurement system-a case study in China
Abstract
With the rapid development of railway construction, the mileage of railway detection has increased dramatically, and railway companies have higher requireme...
Respiratory detection using non-contact sensors
Respiratory detection using non-contact sensors
Abstract
Current respiratory detection study are mainly based on contact respiratory detection technology which has the limitation that human body should wear corres...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...