Additive Manufacturing of a Removable Partial Prosthesis in Titanium Using Binder Jetting Technology: A Brief Research Report

View through CrossRef
Objective: The purpose of this study was to measure the surface roughness and compare the fit of a cobalt-chromium selective laser-melted removable partial denture framework and a titanium binder jetting removable partial denture framework.Materials and methods: A design for a removable partial prosthesis framework was made using 3Shape software, and thereafter, one framework was additively manufactured in cobalt-chromium with selective laser melting and one in titanium using binder jetting technology. The weight of the frameworks was measured, and the surface parameters Sa, Sds, and Sdr were measured by white light interferometry. The fit of the frameworks was analyzed using visual inspection and the pressing test.Results: The weight of the frameworks in their post-printed state was 15.66 g and 7.43 g for cobalt-chromium and titanium, respectively. After finishing and polishing, the cobalt-chromium framework’s outer surface showed a high shine and smooth surface, with lower values in the Sa and Sdr parameters. The visual inspection showed gaps in the titanium framework, and the pressing test detected movement greater than 0.5 mm for the same material.Conclusion: The Ti framework showed higher surface roughness and was left with a lackluster finish after polishing. Also, the fit of the Ti framework was not clinically acceptable. The additive manufacturing binder jetting technology for titanium needs improvement or an adjustment of the settings to be used for clinically removable partial dentures. The cobalt-chromium framework manufactured by selective laser melting showed an acceptable clinical fit and surface roughness.
Title: Additive Manufacturing of a Removable Partial Prosthesis in Titanium Using Binder Jetting Technology: A Brief Research Report
Description:
Objective: The purpose of this study was to measure the surface roughness and compare the fit of a cobalt-chromium selective laser-melted removable partial denture framework and a titanium binder jetting removable partial denture framework.
Materials and methods: A design for a removable partial prosthesis framework was made using 3Shape software, and thereafter, one framework was additively manufactured in cobalt-chromium with selective laser melting and one in titanium using binder jetting technology.
The weight of the frameworks was measured, and the surface parameters Sa, Sds, and Sdr were measured by white light interferometry.
The fit of the frameworks was analyzed using visual inspection and the pressing test.
Results: The weight of the frameworks in their post-printed state was 15.
66 g and 7.
43 g for cobalt-chromium and titanium, respectively.
After finishing and polishing, the cobalt-chromium framework’s outer surface showed a high shine and smooth surface, with lower values in the Sa and Sdr parameters.
The visual inspection showed gaps in the titanium framework, and the pressing test detected movement greater than 0.
5 mm for the same material.
Conclusion: The Ti framework showed higher surface roughness and was left with a lackluster finish after polishing.
Also, the fit of the Ti framework was not clinically acceptable.
The additive manufacturing binder jetting technology for titanium needs improvement or an adjustment of the settings to be used for clinically removable partial dentures.
The cobalt-chromium framework manufactured by selective laser melting showed an acceptable clinical fit and surface roughness.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
THE STUDY OF BIOCHEMICAL INDIXES OF ORAL FLUID IN ORTHODONTIC TREATMENT
THE STUDY OF BIOCHEMICAL INDIXES OF ORAL FLUID IN ORTHODONTIC TREATMENT
The work is devoted to the study of the reactivity of the biochemical composition of saliva in children with SCI, which was used for the treatment of non-removable and removable OA...
Numerical Research on the Effects of Process Parameters on Microdroplet Jetting Characteristics by Piezoelectric Printhead
Numerical Research on the Effects of Process Parameters on Microdroplet Jetting Characteristics by Piezoelectric Printhead
The precision and consistency of the microdroplet jetting procedure are crucial for the casting sand mold’s performance during binder injection. The generation and jetting of micro...
A Review on Binder Jet Additive Manufacturing of 316L Stainless Steel
A Review on Binder Jet Additive Manufacturing of 316L Stainless Steel
Binder jet additive manufacturing enables the production of complex components for numerous applications. Binder jetting is the only powder bed additive manufacturing process that ...
Optimizing Binder Selection for Reduced Contamination in Binder Jetting of Nickel Titanium Alloys
Optimizing Binder Selection for Reduced Contamination in Binder Jetting of Nickel Titanium Alloys
The fabrication of Nickel Titanium (NiTi) alloys through additive manufacturing (AM), particularly binder jetting, presents unique challenges due to residual contamination from bin...
A Sustainable Drive in Well Intervention Operations with Case Studies
A Sustainable Drive in Well Intervention Operations with Case Studies
Abstract Clean out using coiled tubing is the second largest application of coiled tubing after nitrogen kick-off. The advancements in coiled tubing metallurgies to ...
REHABILITATING LONG EDENTULOUS SPAN WITH HYBRID PROSTHESIS - A CASE REPORT
REHABILITATING LONG EDENTULOUS SPAN WITH HYBRID PROSTHESIS - A CASE REPORT
Hybrid prosthesis is a fixed-removable type of prosthesis with semi-precision attachment. Hybrid prosthesis fulfils the objectives of the rehabilitation such as retention, stabilit...