Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Thermal Performance of Load Bearing Cold-formed Steel Walls under Fire Conditions using Numerical Studies

View through CrossRef
Cold-formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.
Title: Thermal Performance of Load Bearing Cold-formed Steel Walls under Fire Conditions using Numerical Studies
Description:
Cold-formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings.
A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls.
Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions.
However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions.
Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions.
Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature.
The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall.
This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results.
It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards.
Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.
Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them.
Effects of realistic design fire conditions are also presented in this paper.

Related Results

Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Identification of Structural and Non-Structural Defects of Load-Bearing Wall Systems in Low Rise Buildings
Identification of Structural and Non-Structural Defects of Load-Bearing Wall Systems in Low Rise Buildings
Malaysia is one of the developed countries that has grown rapidly in various sectors including the construction sector. However, there are some defects in non-structural and struct...
A Detailed Study of the Mineralogy and Petrology of the Kipawa Rare Earth Elements Deposit (Canada)
A Detailed Study of the Mineralogy and Petrology of the Kipawa Rare Earth Elements Deposit (Canada)
Abstract The Kipawa Syenite Complex is composed of peralkaline leucosyenites, mesosyenites, mafic syenites, amphibole syenites, fenites, peralkaline granite, and ...
Thermo-mechanical behavior of energy micropiles
Thermo-mechanical behavior of energy micropiles
Since the first application of piles as energy geostructure in Austria in the 1980s [1], the use of geostructures has steadily increased worldwide. Energy geostructures are complex...
Research on Rolling-Sliding Integrated Auxiliary Bearing and its Application in High Temperature Reactor
Research on Rolling-Sliding Integrated Auxiliary Bearing and its Application in High Temperature Reactor
The active magnetic bearings (AMB), with the advantages of no friction, no abrasion, no lubrication and active control, is used in the primary helium circulator for high-temperatur...
Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...
Solar-Powered Wireless Load Cell Application in Kuwait's Field
Solar-Powered Wireless Load Cell Application in Kuwait's Field
Abstract Artificial-lift systems account for a major portion of Kuwait's heavy-oil production infrastructure. Among these, the sucker rod pump remains the most ec...

Back to Top