Javascript must be enabled to continue!
Thermal Performance of Load Bearing Cold-formed Steel Walls under Fire Conditions using Numerical Studies
View through CrossRef
Cold-formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.
Title: Thermal Performance of Load Bearing Cold-formed Steel Walls under Fire Conditions using Numerical Studies
Description:
Cold-formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings.
A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls.
Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions.
However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions.
Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions.
Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature.
The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall.
This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results.
It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards.
Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.
Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them.
Effects of realistic design fire conditions are also presented in this paper.
Related Results
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
In-Situ Determination of Buildings’ Thermo- Physical Characteristics
In-Situ Determination of Buildings’ Thermo- Physical Characteristics
Ever since the introduction of energy conversion systems in the built environment, buildings have become responsible for a considerable share of global energy consumption. Many cou...
Smart Bearing Sensor
Smart Bearing Sensor
The recent increase in vessel shaftline bearing incidents indicates that a static shaft alignment design may not be suitable for all operational shaftline loading conditions. Hull ...
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
Aportaciones al estudio del comportamiento a flexión de estructuras de acero inoxidable
L'acer inoxidable està essent utilitzat de manera creixent en els últims anys als sectors de la indústria i de l'arquitectura gràcies a la seva resistència a la corrosió, facilitat...
Theoretical and experimental study on cold-formed elements for steel framing in seismic areas
Theoretical and experimental study on cold-formed elements for steel framing in seismic areas
(English) This Thesis presents a theoretical and experimental study on cold-formed elements for seismic-resistant steel framing systems. The focus is on evaluating the feasibility ...
Cold Formed Steel for Residential Construction – Design Philosophy and Durability Assessment
Cold Formed Steel for Residential Construction – Design Philosophy and Durability Assessment
According to a recent estimate by UN Habitat, approximately 3 billion individuals will require suitable housing by the year 2030. This staggering demand translates to the need for ...
Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
Seismic performance cold-Formed steel framed shear walls using in-Frame corrugated steel sheathing
To meet the increasing demand for high strength and non-combustible shear wall systems in mid-rise cold-formed steel (CFS) constructions, this paper investigates the seismic perfor...