Noise Level and Perception of the Closing Click After Heart Valve Replacement with St. Jude Medical and Björk Shiley Monostrut Prostheses

View through CrossRef
Abstract: The metallic click generated by the closure of mechanical heart valve prostheses may severely bother patients, but generated sound energy and the extent of complaints after implantation are not known. In 62 patients, after valve Replacement with St. Jude Medical (SJM) (n = 35) and Björk Shiley Monostrut (BSM) (n = 27) prostheses, sound energy was recorded with a calibrated noise level analyzer at 5, 10, and 100 cm distance from patients and correlated with their complaints. At a distance of 100 cm, the BSM valves produced a significantly higher sound pressure level, 30.5 ± 5 db(A), compared to the SJM valves, 24.1 ±4 db(A) (p = 0.0001). There was no significant difference at shorter distances. After splitting into frequency bands the highest sound pressure levels were observed in the high frequency ranges (8 to 16 kHz) representing the metallic click. BSM valves produced higher sound levels in all frequency ranges at 1 m distance. Seventy‐three percent of all patients were aware of the noise generated by the valve; 20% had disturbed sleep; and 26% preferred a less noisy valve type. Twelve of 27 patients with BSM valves wanted less noisy valves, whereas only 4 of 35 patients with SJM valves wished to have a less noisy valve type (Chi‐square p = 0.003). In patients who could hear their valve measured, sound level was higher than in patients who could not. In 9 of 27 patients with BSM (33%), versus 3 of 35 with SJM prostheses (9%), the clicking caused sleep disturbances. In 85% of BSM, versus 63% SJM, patients could hear their valve (p = 0.05). Since higher sound pressure levels generated by the closing click resulted in an increased rate of complaints, noise level should be regarded as a criterion when a mechanical heart valve prosthesis is selected.
Title: Noise Level and Perception of the Closing Click After Heart Valve Replacement with St. Jude Medical and Björk Shiley Monostrut Prostheses
Description:
Abstract: The metallic click generated by the closure of mechanical heart valve prostheses may severely bother patients, but generated sound energy and the extent of complaints after implantation are not known.
In 62 patients, after valve Replacement with St.
Jude Medical (SJM) (n = 35) and Björk Shiley Monostrut (BSM) (n = 27) prostheses, sound energy was recorded with a calibrated noise level analyzer at 5, 10, and 100 cm distance from patients and correlated with their complaints.
At a distance of 100 cm, the BSM valves produced a significantly higher sound pressure level, 30.
5 ± 5 db(A), compared to the SJM valves, 24.
1 ±4 db(A) (p = 0.
0001).
There was no significant difference at shorter distances.
After splitting into frequency bands the highest sound pressure levels were observed in the high frequency ranges (8 to 16 kHz) representing the metallic click.
BSM valves produced higher sound levels in all frequency ranges at 1 m distance.
Seventy‐three percent of all patients were aware of the noise generated by the valve; 20% had disturbed sleep; and 26% preferred a less noisy valve type.
Twelve of 27 patients with BSM valves wanted less noisy valves, whereas only 4 of 35 patients with SJM valves wished to have a less noisy valve type (Chi‐square p = 0.
003).
In patients who could hear their valve measured, sound level was higher than in patients who could not.
In 9 of 27 patients with BSM (33%), versus 3 of 35 with SJM prostheses (9%), the clicking caused sleep disturbances.
In 85% of BSM, versus 63% SJM, patients could hear their valve (p = 0.
05).
Since higher sound pressure levels generated by the closing click resulted in an increased rate of complaints, noise level should be regarded as a criterion when a mechanical heart valve prosthesis is selected.

Related Results

Doppler Echocardiographic Assessment of the Bjork‐Shiley Monostrut Valve Prosthesis in the Aortic Position
Doppler Echocardiographic Assessment of the Bjork‐Shiley Monostrut Valve Prosthesis in the Aortic Position
In order to determine the standard Doppler hemodynamic characteristics of the Bjork‐Shiley monostrut aortic prosthesis and the value of the continuity equation to calculate the pro...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Comparison of Heart Valve Circumference Examined Before and After 10% Formalin Fixation
Objective: To compare the heart valve circumference before and after 10% formalin fixation. Materials and Methods: The study analyzed 63 Thai human cadaveric hearts. Each heart val...
FACTORS THAT INFLUENCE THE USAGE OF PROSTHESES AMONG PERSONS WITH LOWER LIMB AMPUTATION IN THE KUMASI METROPOLIS
FACTORS THAT INFLUENCE THE USAGE OF PROSTHESES AMONG PERSONS WITH LOWER LIMB AMPUTATION IN THE KUMASI METROPOLIS
There has been numerous technological advancements in dealing with major etiologies of lower limb amputation but lower limb amputation has been on the rise. According to Amoah et a...
Environmental History of Oceanic Noise Pollution
Environmental History of Oceanic Noise Pollution
The concept of “ocean noise” precedes the concept of “ocean noise pollution” by about half a century. Those seeking a body of scholarly literature on ocean noise as an environmenta...
Outcome of heart valve prosthesis in Bangladesh: A retrospective study
Outcome of heart valve prosthesis in Bangladesh: A retrospective study
Background: Prosthetic heart valve for middle aged patients requiring valve replacement remains controversialBecause of the co-morbidities and limited life expectancy, bioprosthesi...
Small Aortic Annulus: Aortic Allografts vs Perceval S
Small Aortic Annulus: Aortic Allografts vs Perceval S
Цель. Оценить и сравнить гемодинамические показатели и изменение качества жизни после имплантации протезов Perceval S и аортальных аллографтов, а также частоту и спектр осложнений ...

Back to Top