Javascript must be enabled to continue!
Cooling Machines and Coefficient of Performance Calculations in Refrigeration Systems
View through CrossRef
A cooling machine is an energy conversion machine that is used to transfer heat from a high temperature hot reservoir to a higher temperature hot reservoir by adding work from outside. In clear terms, a cooling machine is equipment used in the process of cooling a material (fluid) so that it reaches the desired temperature and humidity, by absorbing heat from the material (fluid) that will be conditioned, or in other words absorbing heat (heat) from a cold reservoir. and given to the hot reservoir. The method used in this experiment is a quantitative method where we collect data and then process the data to get the Coefficient of Performance (COP) value. the average temperature in the 5th minute was 24.7 ˚C, in the 10th minute it was 22.34 ˚C, in the 15th minute it was 21.66 ˚C, in the 20th minute it was 21.42 ˚C, at the 25th minute it was 21.32 ˚C, and at the 30th minute it was 21.2 ˚C. COPmax data above the 5th minute to the 10th minute there is a temperature decrease of 5.74%, where the temperature decrease is the highest temperature speed decrease compared to other minutes because the series of tools working in the first 5 minutes has a temperature decrease speed of the minute temperature. 5th minute of 24.7 ˚C towards the 10th minute average temperature of 22.34 ˚C. Meanwhile, the decrease in temperature from the 10th minute to the 15th minute was 2.95%. From the 15th minute to the 20th minute temperature, there was a decrease of 2.82%. For the temperature from the 20th minute to the 25th minute, the temperature decreased by 2.77%. Then from the 25th minute to the 30th minute, the temperature decreased by 2.71%. COPactual data calculations also showed a decrease where in the 5th minute it was 0.75%, in the 10th minute 0.33%, in the 15th minute 0.09%, in the 20th minute 0.03%, while in the 25th and 30th minutes the temperature starts constant with a decrease of 0.01%
University of Pembangunan Nasional Veteran Jawa Timur
Title: Cooling Machines and Coefficient of Performance Calculations in Refrigeration Systems
Description:
A cooling machine is an energy conversion machine that is used to transfer heat from a high temperature hot reservoir to a higher temperature hot reservoir by adding work from outside.
In clear terms, a cooling machine is equipment used in the process of cooling a material (fluid) so that it reaches the desired temperature and humidity, by absorbing heat from the material (fluid) that will be conditioned, or in other words absorbing heat (heat) from a cold reservoir.
and given to the hot reservoir.
The method used in this experiment is a quantitative method where we collect data and then process the data to get the Coefficient of Performance (COP) value.
the average temperature in the 5th minute was 24.
7 ˚C, in the 10th minute it was 22.
34 ˚C, in the 15th minute it was 21.
66 ˚C, in the 20th minute it was 21.
42 ˚C, at the 25th minute it was 21.
32 ˚C, and at the 30th minute it was 21.
2 ˚C.
COPmax data above the 5th minute to the 10th minute there is a temperature decrease of 5.
74%, where the temperature decrease is the highest temperature speed decrease compared to other minutes because the series of tools working in the first 5 minutes has a temperature decrease speed of the minute temperature.
5th minute of 24.
7 ˚C towards the 10th minute average temperature of 22.
34 ˚C.
Meanwhile, the decrease in temperature from the 10th minute to the 15th minute was 2.
95%.
From the 15th minute to the 20th minute temperature, there was a decrease of 2.
82%.
For the temperature from the 20th minute to the 25th minute, the temperature decreased by 2.
77%.
Then from the 25th minute to the 30th minute, the temperature decreased by 2.
71%.
COPactual data calculations also showed a decrease where in the 5th minute it was 0.
75%, in the 10th minute 0.
33%, in the 15th minute 0.
09%, in the 20th minute 0.
03%, while in the 25th and 30th minutes the temperature starts constant with a decrease of 0.
01%.
Related Results
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract
In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...
Modern refrigeration solutions for maritime sector and marine refrigeration transport
Modern refrigeration solutions for maritime sector and marine refrigeration transport
New coming environmental regulations from International Maritime Organization put each involved actor from ship manager, ship owner to cargo owner into a hard situation for a short...
PERHITUNGAN BEBAN PENDINGINAN PADA SISTEM REFRIGERASI AIR BLAST FREEZER
PERHITUNGAN BEBAN PENDINGINAN PADA SISTEM REFRIGERASI AIR BLAST FREEZER
Refrigeration is an attempt to maintain the temperature level of a material or room at a level lower than the temperature of the surrounding environment by absorbing heat from the ...
Co-benefits of efficient and climate friendly cooling in China
Co-benefits of efficient and climate friendly cooling in China
The cooling sector plays a pivotal role in the global economy but significantly contributes to global warming. In 2022, cooling-related emissions accounted for 13% of global greenh...
Refrigeration
Refrigeration
Abstract
This chapter focuses primarily on refrigeration applications, which cover such diverse uses as food processing and storage, supermarket display cases, skating ri...
Erratum in: "Lyudmila D. Akimova (11.08.1929–12.09.2022)"
Erratum in: "Lyudmila D. Akimova (11.08.1929–12.09.2022)"
There was a mistake in the obituary "Lyudmila D. Akimova (11.08.192912.09.2022)" published in 'Refrigeration Technology'2022;111(2) doi: 10.17816/RF112047. Previously published tex...
ANALISA KOEFISIEN UJUK KERJA MESIN PENDINGIN (CHILLER) UNIT 1 PADA POWER HOUSE
ANALISA KOEFISIEN UJUK KERJA MESIN PENDINGIN (CHILLER) UNIT 1 PADA POWER HOUSE
Each refrigerant has different characteristic properties which affect the refrigeration effect and the resulting coefficient of performance (COP). A refrigeration machine that work...
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Modern gas turbine units (GTUs) operate at extremely high temperatures, with mainstream gas temperatures reaching 1700–1750 °C in transport and military applications, while heat-re...