Spectral contaminant identifier for off-axis integrated cavity output spectroscopy measurements of liquid water isotopes
View through CrossRef
Developments in cavity-enhanced absorption spectrometry have made it possible to measure water isotopes using faster, more cost-effective field-deployable instrumentation. Several groups have attempted to extend this technology to measure water extracted from plants and found that other extracted organics absorb light at frequencies similar to that absorbed by the water isotopomers, leading to δ2H and δ18O measurement errors (Δδ2H and Δδ18O). In this note, the off-axis integrated cavity output spectroscopy (ICOS) spectra of stable isotopes in liquid water is analyzed to determine the presence of interfering absorbers that lead to erroneous isotope measurements. The baseline offset of the spectra is used to calculate a broadband spectral metric, mBB, and the mean subtracted fit residuals in two regions of interest are used to determine a narrowband metric, mNB. These metrics are used to correct for Δδ2H and Δδ18O. The method was tested on 14 instruments and Δδ18O was found to scale linearly with contaminant concentration for both narrowband (e.g., methanol) and broadband (e.g., ethanol) absorbers, while Δδ2H scaled linearly with narrowband and as a polynomial with broadband absorbers. Additionally, the isotope errors scaled logarithmically with mNB. Using the isotope error versus mNB and mBB curves, Δδ2H and Δδ18O resulting from methanol contamination were corrected to a maximum mean absolute error of 0.93 ‰ and 0.25 ‰ respectively, while Δδ2H and Δδ18O from ethanol contamination were corrected to a maximum mean absolute error of 1.22 ‰ and 0.22 ‰. Large variation between instruments indicates that the sensitivities must be calibrated for each individual isotope analyzer. These results suggest that the properly calibrated interference metrics can be used to correct for polluted samples and extend off-axis ICOS measurements of liquid water to include plant waters, soil extracts, wastewater, and alcoholic beverages. The general technique may also be extended to other laser-based analyzers including methane and carbon dioxide isotope sensors.
Title: Spectral contaminant identifier for off-axis integrated cavity output spectroscopy measurements of liquid water isotopes
Description:
Developments in cavity-enhanced absorption spectrometry have made it possible to measure water isotopes using faster, more cost-effective field-deployable instrumentation.
Several groups have attempted to extend this technology to measure water extracted from plants and found that other extracted organics absorb light at frequencies similar to that absorbed by the water isotopomers, leading to δ2H and δ18O measurement errors (Δδ2H and Δδ18O).
In this note, the off-axis integrated cavity output spectroscopy (ICOS) spectra of stable isotopes in liquid water is analyzed to determine the presence of interfering absorbers that lead to erroneous isotope measurements.
The baseline offset of the spectra is used to calculate a broadband spectral metric, mBB, and the mean subtracted fit residuals in two regions of interest are used to determine a narrowband metric, mNB.
These metrics are used to correct for Δδ2H and Δδ18O.
The method was tested on 14 instruments and Δδ18O was found to scale linearly with contaminant concentration for both narrowband (e.
g.
, methanol) and broadband (e.
g.
, ethanol) absorbers, while Δδ2H scaled linearly with narrowband and as a polynomial with broadband absorbers.
Additionally, the isotope errors scaled logarithmically with mNB.
Using the isotope error versus mNB and mBB curves, Δδ2H and Δδ18O resulting from methanol contamination were corrected to a maximum mean absolute error of 0.
93 ‰ and 0.
25 ‰ respectively, while Δδ2H and Δδ18O from ethanol contamination were corrected to a maximum mean absolute error of 1.
22 ‰ and 0.
22 ‰.
Large variation between instruments indicates that the sensitivities must be calibrated for each individual isotope analyzer.
These results suggest that the properly calibrated interference metrics can be used to correct for polluted samples and extend off-axis ICOS measurements of liquid water to include plant waters, soil extracts, wastewater, and alcoholic beverages.
The general technique may also be extended to other laser-based analyzers including methane and carbon dioxide isotope sensors.
Related Results
Hydraulic Pump Contaminant Wear
Hydraulic Pump Contaminant Wear
The contaminant wear of any pump depends on the operational and the contaminant severity as well as the inherent contaminant sensitivity of the pump. In order to evaluate the conta...
Spatiotemporal variations of isotopes in snow and snowmelt in the subarctic setting at Pallas catchment, Finland
Spatiotemporal variations of isotopes in snow and snowmelt in the subarctic setting at Pallas catchment, Finland
<p>Due to the rise in global temperature, changes in precipitation patterns are predicted particularly in Arctic regions. Such changes in patterns and modifications i...
Self-reliance and independently developed high-finesse spherical ultrastable optical reference cavity
Self-reliance and independently developed high-finesse spherical ultrastable optical reference cavity
Ultra-stable reference cavity with high finesse is a crucial component in a narrow-linewidth laser system which is widely used in time and frequency metrology, the test of Lorentz ...
Integrated hydrological modelling for sustainable water allocation planning : Mkomazi Basin, South Africa case study
Integrated hydrological modelling for sustainable water allocation planning : Mkomazi Basin, South Africa case study
Allocation of freshwater resources between societal needs and natural ecological systems is of great concern for water managers. This development has challenged decision-makers reg...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Fiber-cavity enhanced and high-fidelity optical memory in cold atom ensemble
Fiber-cavity enhanced and high-fidelity optical memory in cold atom ensemble
Entanglement between a photon and an atomic memory is an important tool for quantum repeater research. By using the Duan-Lukin-Cirac-Zoller (DLCZ) process in the atomic ensemble, q...
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Use of Formation Water and Associated Gases and their Simultaneous Utilization for Obtaining Microelement Concentrates Fresh Water and Drinking Water
Abstract Purpose: The invention relates to the oil industry, inorganic chemistry, in particular, to the methods of complex processing of formation water, using flare gas of oil and...
Design and analysis of high-spectral resolution lidar discriminator
Design and analysis of high-spectral resolution lidar discriminator
An accurate aerosol optical property can be obtained by a high spectral resolution lidar (HSRL) technique, which employs a narrow spectral filter to suppress Mie scattering in the ...