Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Repeatability of pentacam AXL in determining axial length and ocular indices in people with irregular cornea

View through CrossRef
Aims/Purpose: To determine the repeatability of Pentacam AXL in determining ocular axial length and some corneal indices in people with irregular corneas.Methods: Ocular biometry using Pentacam AXL underwent in this study. The Pentacam AXL measurements were done 3 times 10‐minutes apart. To evaluate the repeatability, the intraclass correlation coefficient (ICC), were calculated.Results: In this study, 141 eyes of 141 individuals with irregular cornea aged 60 to 91 years (64 ± 15.7) were included. The ICC of axial length, flat keratometry, steep keratometry, anterior chamber depth, central corneal thickness and corneal diameter measurements were 0.957, 0.981, 0.989, 0.980, 0.923 and 0.981 respectively. In cases with long axial length (>24.5mm) the ICC of axial length, flat keratometry, steep keratometry, anterior chamber depth, central corneal thickness and corneal diameter measurements were 0.427, 0.946, 0.993, 0.988, 0.861 and 0.989 respectively.Conclusions: The results of this study showed that generally Pentacam AXL has a high repeatability in measuring the axial length and some corneal indices of the eye in irregular corneas. However, it should be note that Pentacam AXL has no repeatability in irregular corneas with long axial length.
Title: Repeatability of pentacam AXL in determining axial length and ocular indices in people with irregular cornea
Description:
Aims/Purpose: To determine the repeatability of Pentacam AXL in determining ocular axial length and some corneal indices in people with irregular corneas.
Methods: Ocular biometry using Pentacam AXL underwent in this study.
The Pentacam AXL measurements were done 3 times 10‐minutes apart.
To evaluate the repeatability, the intraclass correlation coefficient (ICC), were calculated.
Results: In this study, 141 eyes of 141 individuals with irregular cornea aged 60 to 91 years (64 ± 15.
7) were included.
The ICC of axial length, flat keratometry, steep keratometry, anterior chamber depth, central corneal thickness and corneal diameter measurements were 0.
957, 0.
981, 0.
989, 0.
980, 0.
923 and 0.
981 respectively.
In cases with long axial length (>24.
5mm) the ICC of axial length, flat keratometry, steep keratometry, anterior chamber depth, central corneal thickness and corneal diameter measurements were 0.
427, 0.
946, 0.
993, 0.
988, 0.
861 and 0.
989 respectively.
Conclusions: The results of this study showed that generally Pentacam AXL has a high repeatability in measuring the axial length and some corneal indices of the eye in irregular corneas.
However, it should be note that Pentacam AXL has no repeatability in irregular corneas with long axial length.

Related Results

Abstract 406: Mechanism of AXL regulation in chemotherapy resistance
Abstract 406: Mechanism of AXL regulation in chemotherapy resistance
Abstract Constitutive activation of receptor tyrosine kinase AXL is an important phenomenon in chemotherapy resistance and is highly expressed in several malignancie...
Axl, A Receptor Tyrosine Kinase, Mediates Flow-Induced Vascular Remodeling
Axl, A Receptor Tyrosine Kinase, Mediates Flow-Induced Vascular Remodeling
Intima-media thickening (IMT) in response to hemodynamic stress is a physiological process that requires coordinated signaling among endothelial, inflammatory, and vascular smooth ...
Abstract 1572: Overexpression of Axl delays metastatic outgrowth of prostate cancer bone marrow disseminated tumor cells
Abstract 1572: Overexpression of Axl delays metastatic outgrowth of prostate cancer bone marrow disseminated tumor cells
Abstract The presence of detectable metastases in the bone marrow of prostate cancer patients represents lethal, incurable disease. These metastases that may emerge ...
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Purpose: To compare toric IOL (Intra Ocular Lenses) suggestions for power, toric, and IOL alignment between the IOLMaster 700 and Pentacam AXL (Axial Length). Methods: This single-...
Structural analysis of tilvestamab in complex with AXL
Structural analysis of tilvestamab in complex with AXL
Abstract AXL is a receptor tyrosine kinase with a significant role in various biological processes and important medical implications, particularly in cancer. AXL trans...
OptimEYEzing Emergency Skills: A Novel Model for Ocular Procedural Education for Emergency Medicine Residents
OptimEYEzing Emergency Skills: A Novel Model for Ocular Procedural Education for Emergency Medicine Residents
Audience: This model for ocular procedural education is designed to instruct emergency medicine residents of all levels of training. Introduction: Ocular complaints are a common pr...

Back to Top