Field comparison of three nitrous oxide samplers
View through CrossRef
Objective: The primary objective of this study was to determine the agreement between a Miran SapphIRe infrared ambient analyzer, conventional passive dosimeter badges (badges), and thermal desorption tubes (TD tubes) during nitrous oxide (N2O) sampling in Indian Health Service (IHS) dental clinics. Agreement of ± 15% between TD Tubes and the reference Miran SapphIRe could suggest the TD tubes as an alternative for future passive N2O sampling.
Methods: Passive samples and direct-reading measurements were taken in the breathing zone of six dentists at five IHS dental clinics where N2O was used as the dental procedure anesthetic. Twenty-four sample sets were collected, each consisting of one TWA Miran SapphIRe measurement, two badges, and three TD tubes. A repeated measures Analysis of Variance (ANOVA) test was performed to identify statistically significant differences between the three sampling devices. The Bland-Altman method was used to investigate the specific level of agreement.
Results: All devices had significantly different N2O concentrations (p<.05). When plotted, badge reported an upper Limit of Agreement (LOA) 13 and lower LOA 0.2 the TD tube reported upper LOA 2.5 and lower LOA 0.2.
Conclusion: Neither of the passive samplers met the pre-defined Level of Agreement (± 15%) acceptable to IHS. However, TD tubes may be a good alternative to the conventional passive dosimeter badge, as they displayed closer agreement to the Miran SapphIRe.
F1000 Research Ltd
Title: Field comparison of three nitrous oxide samplers
Description:
Objective: The primary objective of this study was to determine the agreement between a Miran SapphIRe infrared ambient analyzer, conventional passive dosimeter badges (badges), and thermal desorption tubes (TD tubes) during nitrous oxide (N2O) sampling in Indian Health Service (IHS) dental clinics.
Agreement of ± 15% between TD Tubes and the reference Miran SapphIRe could suggest the TD tubes as an alternative for future passive N2O sampling.
Methods: Passive samples and direct-reading measurements were taken in the breathing zone of six dentists at five IHS dental clinics where N2O was used as the dental procedure anesthetic.
Twenty-four sample sets were collected, each consisting of one TWA Miran SapphIRe measurement, two badges, and three TD tubes.
A repeated measures Analysis of Variance (ANOVA) test was performed to identify statistically significant differences between the three sampling devices.
The Bland-Altman method was used to investigate the specific level of agreement.
Results: All devices had significantly different N2O concentrations (p<.
05).
When plotted, badge reported an upper Limit of Agreement (LOA) 13 and lower LOA 0.
2 the TD tube reported upper LOA 2.
5 and lower LOA 0.
2.
Conclusion: Neither of the passive samplers met the pre-defined Level of Agreement (± 15%) acceptable to IHS.
However, TD tubes may be a good alternative to the conventional passive dosimeter badge, as they displayed closer agreement to the Miran SapphIRe.
Related Results
Postoperative Pulmonary Complications in the ENIGMA II Trial: A Post Hoc Analysis
Postoperative Pulmonary Complications in the ENIGMA II Trial: A Post Hoc Analysis
Background
Nitrous oxide promotes absorption atelectasis in poorly ventilated lung segments at high inspired concentrations. The Evaluation of Nitrous oxide In the Gas ...
Nitrous oxide in the North Atlantic Ocean
Nitrous oxide in the North Atlantic Ocean
Abstract. In order to investigate the role of the North Atlantic Ocean as a source of atmospheric nitrous oxide and to decipher the major formation pathways of nitrous oxide, measu...
A high capacity, automatic and small-volume water sampler
A high capacity, automatic and small-volume water sampler
<p>Field deployable and portable automatic water samplers are common tools in hydrology. They allow the unattended collection of water samples at predetermined times ...
Sevoflurane concentration for cannulation in developmental disabilities
Sevoflurane concentration for cannulation in developmental disabilities
Abstract
Objective: The goal of this study was to compare the end-tidal sevoflurane concentration and time for intravenous cannulation at induction of anesthesia using sevo...
Diffusion of Xenon and Nitrous Oxide into the Bowel
Diffusion of Xenon and Nitrous Oxide into the Bowel
Background
Nitrous oxide diffuses easily from blood into air filled spaces. Xenon is also a relatively insoluble gas, like nitrous oxide. Therefore, the authors measure...
Comparison of bioaerosol collection methods in the detection of airborne influenza virus
Comparison of bioaerosol collection methods in the detection of airborne influenza virus
<p>Detection of airborne influenza virus is needed in order to determine exposure and prevent and control infections. Few researchers have successfully detected airborne infl...
Lachgas: om te lachen?
Lachgas: om te lachen?
Nitrous oxide: no laughing matter In this case study, the authors discuss the dangers and medical relevance of the increasing recreational use of nitrous oxide. Nitrous oxide is a ...
Nitrous oxide in the North Atlantic Ocean
Nitrous oxide in the North Atlantic Ocean
Abstract. In order to get a comprehensive picture of the distribution of nitrous oxide (N2O) in the North Atlantic Ocean, measurements of dissolved nitrous oxide were made during t...