Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Diffusion of Xenon and Nitrous Oxide into the Bowel

View through CrossRef
Background Nitrous oxide diffuses easily from blood into air filled spaces. Xenon is also a relatively insoluble gas, like nitrous oxide. Therefore, the authors measured xenon diffusion into obstructed bowel segments during xenon anesthesia and compared this with nitrous oxide and nitrogen diffusion. Methods Twenty-one pentobarbital-anesthetized pigs were randomly assigned to three groups to receive either xenon-oxygen, nitrous oxide-oxygen, or nitrogen-oxygen (75%-25%), respectively. In each animal four bowel segments of 15-cm length were isolated. A pressure-measuring catheter was inserted into the lumen, and 30 ml of room air was injected into the segments. Anesthesia with the selected gas mixture was performed for 4 h. Pressure in the segments was measured continuously. The volume of gaseous bowel content was measured on completion of the study. Results The median volume of bowel gas in animals breathing nitrous oxide was 88.0 ml as compared with 39.0 ml with xenon anesthesia and 21.5 ml in the nitrogen-oxygen group. After 4 h of anesthesia, the intraluminal pressures in the nitrous oxide group were found to be significantly greater than in the control group and in the xenon group. Conclusions The amount of diffused gas was significantly lower during xenon anesthesia than with nitrous oxide anesthesia but greater than with controls. Blood solubility can therefore be regarded as an important factor influencing gas diffusion into air filled cavities.
Title: Diffusion of Xenon and Nitrous Oxide into the Bowel
Description:
Background Nitrous oxide diffuses easily from blood into air filled spaces.
Xenon is also a relatively insoluble gas, like nitrous oxide.
Therefore, the authors measured xenon diffusion into obstructed bowel segments during xenon anesthesia and compared this with nitrous oxide and nitrogen diffusion.
Methods Twenty-one pentobarbital-anesthetized pigs were randomly assigned to three groups to receive either xenon-oxygen, nitrous oxide-oxygen, or nitrogen-oxygen (75%-25%), respectively.
In each animal four bowel segments of 15-cm length were isolated.
A pressure-measuring catheter was inserted into the lumen, and 30 ml of room air was injected into the segments.
Anesthesia with the selected gas mixture was performed for 4 h.
Pressure in the segments was measured continuously.
The volume of gaseous bowel content was measured on completion of the study.
Results The median volume of bowel gas in animals breathing nitrous oxide was 88.
0 ml as compared with 39.
0 ml with xenon anesthesia and 21.
5 ml in the nitrogen-oxygen group.
After 4 h of anesthesia, the intraluminal pressures in the nitrous oxide group were found to be significantly greater than in the control group and in the xenon group.
Conclusions The amount of diffused gas was significantly lower during xenon anesthesia than with nitrous oxide anesthesia but greater than with controls.
Blood solubility can therefore be regarded as an important factor influencing gas diffusion into air filled cavities.

Related Results

Molecular dynamics study of diffusion of xenon in water at different temperatures
Molecular dynamics study of diffusion of xenon in water at different temperatures
Molecular Dynamics simulation was performed using 2 xenon atoms as solute and 300 water molecules as solvent. We have studied the structural properties as well as transport propert...
Nitrous oxide in the North Atlantic Ocean
Nitrous oxide in the North Atlantic Ocean
Abstract. In order to investigate the role of the North Atlantic Ocean as a source of atmospheric nitrous oxide and to decipher the major formation pathways of nitrous oxide, measu...
Postoperative Pulmonary Complications in the ENIGMA II Trial: A Post Hoc Analysis
Postoperative Pulmonary Complications in the ENIGMA II Trial: A Post Hoc Analysis
Background Nitrous oxide promotes absorption atelectasis in poorly ventilated lung segments at high inspired concentrations. The Evaluation of Nitrous oxide In the Gas ...
Physician and miracle worker. The cult of Saint Sampson the Xenodochos and his images in eastern Orthodox medieval painting
Physician and miracle worker. The cult of Saint Sampson the Xenodochos and his images in eastern Orthodox medieval painting
Saint Sampson, whose feast is celebrated on June 27, was depicted among holy physicians. However, his images were not frequent. He was usually accompanied with Saint Mokios (...
Sevoflurane concentration for cannulation in developmental disabilities
Sevoflurane concentration for cannulation in developmental disabilities
Abstract Objective: The goal of this study was to compare the end-tidal sevoflurane concentration and time for intravenous cannulation at induction of anesthesia using sevo...
Diffusion and Ion Conduction in Cation-Conducting Oxide Glasses
Diffusion and Ion Conduction in Cation-Conducting Oxide Glasses
In this Chapter we review knowledge about diffusion and cation conduction in oxide glasses. We first remind the reader in Section 1 of major aspects of the glassy state and recall ...
Xenon Neuroprotection in Experimental Stroke
Xenon Neuroprotection in Experimental Stroke
Background Xenon has been proven to be neuroprotective in experimental brain injury. The authors hypothesized that xenon would improve outcome from focal cerebral ische...

Back to Top