Thermal Performance Comparison between Single and Double Storey Terrace Houses in Melaka, Malaysia
View through CrossRef
Over the past decade many studies were conducted to investigate the thermal performance of terraced houses in Malaysia. It was found that this housing typology failed to address the need for thermal comfort and alternatives to the narrow frontage with deep plan have been proposed with simulated good thermal performance. Although this is good progress for new generation of terraced houses, millions of units of terraced houses are still in use and new units with the outdated existing plans continued to get built due to consistently very high demand due to progressive urbanisation and rapid economic developments. Therefore, it is imperative that the thermal comfort issue for existing terraced houses is dealt with and through this paper a comparison between single and double storey terraced houses is made through analysis of indoor environmental monitoring (ambient temperature, relative humidity and air velocity) of two (2) selected case studies in Merlimau, Melaka. Contrary to popular belief, it is found that there is no statistical difference between both sets of indoor temperature and relative humidity between the case studies. This finding is indicative of the consistent and stable temporal temperature highs and lows in a 24 hour cycle despite the difference in indoor volume and distance between the ground floor and the roof cavity. Much of the reason is due to the materiality of the terraced houses construction and unsealed and uninsulated building envelope. Therefore, further research into improving the thermal performance of existing terraced houses of any typology have to be conducted to allow thermal comfort and to reduce reliance on high energy consuming air-conditioning.
Trans Tech Publications, Ltd.
Title: Thermal Performance Comparison between Single and Double Storey Terrace Houses in Melaka, Malaysia
Description:
Over the past decade many studies were conducted to investigate the thermal performance of terraced houses in Malaysia.
It was found that this housing typology failed to address the need for thermal comfort and alternatives to the narrow frontage with deep plan have been proposed with simulated good thermal performance.
Although this is good progress for new generation of terraced houses, millions of units of terraced houses are still in use and new units with the outdated existing plans continued to get built due to consistently very high demand due to progressive urbanisation and rapid economic developments.
Therefore, it is imperative that the thermal comfort issue for existing terraced houses is dealt with and through this paper a comparison between single and double storey terraced houses is made through analysis of indoor environmental monitoring (ambient temperature, relative humidity and air velocity) of two (2) selected case studies in Merlimau, Melaka.
Contrary to popular belief, it is found that there is no statistical difference between both sets of indoor temperature and relative humidity between the case studies.
This finding is indicative of the consistent and stable temporal temperature highs and lows in a 24 hour cycle despite the difference in indoor volume and distance between the ground floor and the roof cavity.
Much of the reason is due to the materiality of the terraced houses construction and unsealed and uninsulated building envelope.
Therefore, further research into improving the thermal performance of existing terraced houses of any typology have to be conducted to allow thermal comfort and to reduce reliance on high energy consuming air-conditioning.
Related Results
Optimum Location of Soft Storey in Multi-Storeyed Building
Optimum Location of Soft Storey in Multi-Storeyed Building
The present study is focus on 11-storey reinforced concrete buildings to optimize the location of soft storey under seismic zone-v. The plan of building 40m x 40m is considered. In...
Effect of Aspect Ratio on High Rise Structures with Diagrid
Effect of Aspect Ratio on High Rise Structures with Diagrid
Urbanization and population explosion in the present times has led to increase in demand for land and residencies but the availability of land is scare i.e reason a trend has evolv...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
GEOPOLITIK MELAKA DAN PILIHAN POLITIK PENGUNDI DALAM PILIHAN RAYA DUN MELAKA 2021
GEOPOLITIK MELAKA DAN PILIHAN POLITIK PENGUNDI DALAM PILIHAN RAYA DUN MELAKA 2021
Politik Negeri Melaka terkenal sebagai kubu kuat BN sejak sebelum merdeka hingga PRU 2013. Namun pada PRU 2018, Melaka jatuh kepada parti pembangkang iaitu PH. 22 bulan selepas PH ...
A Comparison of Rusunawa A4 IPB Building Storey Shear using Seismic Code of SNI 1726-2002 and SNI 1726-2012
A Comparison of Rusunawa A4 IPB Building Storey Shear using Seismic Code of SNI 1726-2002 and SNI 1726-2012
Indonesia is a high-risk earthquake country. It passed by Pacific Ring of Fire and surrounded by Eurasian, Pacific, Philippines and Indo-Australian plates. Indonesia government has...
Eco-Compensation Mechanism Construction of Chongyi Hakka Terrace Ecosystem
Eco-Compensation Mechanism Construction of Chongyi Hakka Terrace Ecosystem
Chongyi Hakka Terrace is located in Chongyi County in the south of Jiangxi Province, which is the largest Hakka Terrace in China. As a special agricultural ecosystem, it provides m...
Woodcarving Motifs at Melaka Traditional Houses: Kampung Morten
Woodcarving Motifs at Melaka Traditional Houses: Kampung Morten
Woodcarving is an important component for the traditional Malay houses. Malay traditional houses becomes a symbol of ancient craftmanship skills which having beautiful architecture...