Islanding detection method of multi‐port photovoltaic DC micro grid based on harmonic impedance measurement
View through CrossRef
DC Grid does not transmit reactive power, nor does it offer frequency and phase issues. This results in malfunction of conventional islanding detection methods (IDMs) that rely on the above quantities. At present, the DC IDMs proposed in literatures are mostly active power injection methods based on DC/DC converters. However, in a multi‐photovoltaic (PV) DC system, the synchronization of the injection of converters is difficult to guarantee, which may lead to detection failure. This paper proposes an impedance measurement IDM for multi‐PV DC micro grid based on the analysis of high‐frequency impedance model of power electronic devices. The impedance of DC converters is constant at high frequency and the harmonic impedance of the system changes significantly after islanding, so that islanding operation can be accurately detected. The harmonic impedance change directly reflects the structural changes of the system, and its calculation requires less disturbance intensity, which avoids the requirement of synchronous injection. Therefore, the method uses a DC/DC converter for injection, without the need for additional injection equipment. The method has little influence on power quality and theoretically has no none detection zone. Simulation results show that the method can perform accurately islanding detection in multi‐PV DC micro grid.
Institution of Engineering and Technology (IET)
Title: Islanding detection method of multi‐port photovoltaic DC micro grid based on harmonic impedance measurement
Description:
DC Grid does not transmit reactive power, nor does it offer frequency and phase issues.
This results in malfunction of conventional islanding detection methods (IDMs) that rely on the above quantities.
At present, the DC IDMs proposed in literatures are mostly active power injection methods based on DC/DC converters.
However, in a multi‐photovoltaic (PV) DC system, the synchronization of the injection of converters is difficult to guarantee, which may lead to detection failure.
This paper proposes an impedance measurement IDM for multi‐PV DC micro grid based on the analysis of high‐frequency impedance model of power electronic devices.
The impedance of DC converters is constant at high frequency and the harmonic impedance of the system changes significantly after islanding, so that islanding operation can be accurately detected.
The harmonic impedance change directly reflects the structural changes of the system, and its calculation requires less disturbance intensity, which avoids the requirement of synchronous injection.
Therefore, the method uses a DC/DC converter for injection, without the need for additional injection equipment.
The method has little influence on power quality and theoretically has no none detection zone.
Simulation results show that the method can perform accurately islanding detection in multi‐PV DC micro grid.
Related Results
KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
KONTESTASI TASAWUF SUNNÎ DAN TASAWUF FALSAFÎ DI NUSANTARA
<p>This article scrutinizes the history of Islamic development in Nusantara between 15th to 18th centuries, which has been colored from theological mysticism thought. Uniquel...
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
Korelasi Kadar Karboksihemoglobin terhadap Tekanan Darah Penduduk di Sekitar Terminal Bus Tirtonadi Surakarta
<table width="645" border="1" cellspacing="0" cellpadding="0"><tbody><tr><td valign="top" width="408"><p> </p><p>Carbon monoxide is a gas ...
An Anti-Islanding Protection Method Based on Voltage-Synchronous Impedance Angle Measurements
An Anti-Islanding Protection Method Based on Voltage-Synchronous Impedance Angle Measurements
Grid-tied distributed generators (DGs) need to be equipped with anti-islanding protection to avoid the impact of unplanned islanding, which would affect system stability, auto-recl...
Islanding detection method for multi‐terminal renewable power DC distribution system
Islanding detection method for multi‐terminal renewable power DC distribution system
Abstract
Most of the traditional islanding detection methods are designed for renewable sources in AC systems and cannot be directly applied in multi‐terminal DC ...
Efeitos do Pilates solo e exercício resistido sobre a obesidade central e o índice de massa corpórea em idosos
Efeitos do Pilates solo e exercício resistido sobre a obesidade central e o índice de massa corpórea em idosos
<!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:TrackMoves /> <w:TrackFormatting /> &l...
Hungarian neutral vowels: A microcomparison
Hungarian neutral vowels: A microcomparison
<!--[if gte mso 9]><xml> <o:OfficeDocumentSettings> <o:AllowPNG /> </o:OfficeDocumentSettings> </xml><![endif]--> <!--[if gte mso 9]>...
A Hybrid Active Frequency Drift and Pearson Correlation Method for Islanding Detection in Grid-Connected Photovoltaic Systems
A Hybrid Active Frequency Drift and Pearson Correlation Method for Islanding Detection in Grid-Connected Photovoltaic Systems
Abstract
Islanding detection remains a critical technical challenge in grid-connected photovoltaic (PV) systems, as delayed or missed detection can compromise both ...
Comparative Study of the Structural Resistance of Sawah rice and Gogo rice
Comparative Study of the Structural Resistance of Sawah rice and Gogo rice
<!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:TrackMoves /> <w:TrackFormatting /> &l...