Javascript must be enabled to continue!
Measurement and Removal of Asbestos in Residential Dwellings to be Demolished - Urban Transformation Experience in Izmir-Turkey
View through CrossRef
Abstract
Asbestos has been used extensively in the construction industry for its superior insulation properties before its health hazards were discovered and eventually getting banned. It would not be wrong to assume all residential buildings built before the 2000s in Turkey contain asbestos. Therefore, it is important to raise awareness of the potential danger of asbestos exposure during demolition work and to identify asbestos-containing materials and ensure their safe removal and disposal. This study summarizes the efforts being made in the “Asbestos Free Demolition” EU project, which is executed to determine the residential dwellings containing asbestos in Izmir. The project included field study to determine asbestos presence in the buildings that were damaged during the 2020 earthquake. 505 bulk samples were taken from 50 buildings that would go through the demolition process. 11 buildings were found to contain asbestos. This rate corresponds to 22%. In addition to asbestos removal processes in these buildings containing asbestos, air measurements were taken from each building. The detected asbestos type was 60% chrysotile (white asbestos). The concentration of asbestos in the air is ignorable also personal exposure did not exceed the permissible exposure limit (PEL) for 0.1 fiber/cm3. Results demonstrate the findings of asbestos-containing materials and suggestions before demolition work. Also, it is expected that the database created for this study could be useful in other studies involving Turkey, where accurate statistical data related with asbestos measurements is still difficult to obtain.
Springer Science and Business Media LLC
Title: Measurement and Removal of Asbestos in Residential Dwellings to be Demolished - Urban Transformation Experience in Izmir-Turkey
Description:
Abstract
Asbestos has been used extensively in the construction industry for its superior insulation properties before its health hazards were discovered and eventually getting banned.
It would not be wrong to assume all residential buildings built before the 2000s in Turkey contain asbestos.
Therefore, it is important to raise awareness of the potential danger of asbestos exposure during demolition work and to identify asbestos-containing materials and ensure their safe removal and disposal.
This study summarizes the efforts being made in the “Asbestos Free Demolition” EU project, which is executed to determine the residential dwellings containing asbestos in Izmir.
The project included field study to determine asbestos presence in the buildings that were damaged during the 2020 earthquake.
505 bulk samples were taken from 50 buildings that would go through the demolition process.
11 buildings were found to contain asbestos.
This rate corresponds to 22%.
In addition to asbestos removal processes in these buildings containing asbestos, air measurements were taken from each building.
The detected asbestos type was 60% chrysotile (white asbestos).
The concentration of asbestos in the air is ignorable also personal exposure did not exceed the permissible exposure limit (PEL) for 0.
1 fiber/cm3.
Results demonstrate the findings of asbestos-containing materials and suggestions before demolition work.
Also, it is expected that the database created for this study could be useful in other studies involving Turkey, where accurate statistical data related with asbestos measurements is still difficult to obtain.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Current Perspectives on Cystic Echinococcosis: A Systematic Review
Current Perspectives on Cystic Echinococcosis: A Systematic Review
Abstract
Introduction: Hydatidosis, a zoonotic disease caused by the larval stage of Echinococcus granulosus, is a significant public health concern with notable economic impact. I...
De gevel – een intermediair element tussen buiten en binnen
De gevel – een intermediair element tussen buiten en binnen
This study is based on the fact that all people have a basic need for protection from other people (and animals) as well as from the elements (the exterior climate). People need a ...
Potentially toxic elements (PTEs) associated with asbestos chrysotile, tremolite and actinolite in the Calabria region (Italy)
Potentially toxic elements (PTEs) associated with asbestos chrysotile, tremolite and actinolite in the Calabria region (Italy)
Potentially toxic elements (PTEs) host in asbestos elongate mineral particles is one of the factors which have been invoked to explain their toxicity/pathogenicity effects.This stu...
DISP-05. Exposure to asbestos in buildings: A silent risk of brain tumors during maintenance and occupancy
DISP-05. Exposure to asbestos in buildings: A silent risk of brain tumors during maintenance and occupancy
Abstract
BACKGROUND
Asbestos is recognized as a proven human carcinogen. Many buildings constructed before 2000 continue ...
Chest Wall Hydatid Cysts: A Systematic Review
Chest Wall Hydatid Cysts: A Systematic Review
Abstract
Introduction
Given the rarity of chest wall hydatid disease, information on this condition is primarily drawn from case reports. Hence, this study systematically reviews t...