Testing Sensitivity of A-Type Residual Current Devices to Earth Fault Currents with Harmonics
View through CrossRef
In many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in low-voltage power systems is commonly performed with the use of residual current devices (RCDs). In the presence of harmonics, the RCDs may have a tripping current significantly different from that provided for the nominal sinusoidal waveform. Thus, in some cases, protection against electric shock may not be effective. The aim of this paper is to present the result of a wide-range laboratory test of the sensitivity of A-type RCDs in the presence of harmonics. This test has shown that the behavior of RCDs in the presence of harmonics can be varied, including the cases in which the RCD does not react to the distorted earth fault current, as well as cases in which the sensitivity of the RCD is increased. The properties of the main elements of RCDs, including the current sensor, for high-frequency current components are discussed as well.
Title: Testing Sensitivity of A-Type Residual Current Devices to Earth Fault Currents with Harmonics
Description:
In many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed.
Such equipment is used both in industrial and domestic installations.
A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics.
Nowadays, protection against electric shock in low-voltage power systems is commonly performed with the use of residual current devices (RCDs).
In the presence of harmonics, the RCDs may have a tripping current significantly different from that provided for the nominal sinusoidal waveform.
Thus, in some cases, protection against electric shock may not be effective.
The aim of this paper is to present the result of a wide-range laboratory test of the sensitivity of A-type RCDs in the presence of harmonics.
This test has shown that the behavior of RCDs in the presence of harmonics can be varied, including the cases in which the RCD does not react to the distorted earth fault current, as well as cases in which the sensitivity of the RCD is increased.
The properties of the main elements of RCDs, including the current sensor, for high-frequency current components are discussed as well.
Related Results
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems.
Concerning fault detection, interv...
Deformational Processes Accommodating Slip on an Active Low-Angle Normal Fault, Suckling-Dayman Metamorphic Core Complex, Papua New Guinea
Deformational Processes Accommodating Slip on an Active Low-Angle Normal Fault, Suckling-Dayman Metamorphic Core Complex, Papua New Guinea
<p><b>Detachment faults that can be shown to have slipped at dips <30° in highly extended continental crust are referred to as “Low-Angle Normal Faults” (LANFs). The...
Theia can arrive late and be oxidized, but not if it is large compared to proto-Earth
Theia can arrive late and be oxidized, but not if it is large compared to proto-Earth
The Moon-forming impact was the most significant event during the accretion of Earth substantially establishing the physical and chemical states of the Earth-Moon system. In the ca...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Late Quaternary Activity: Kouma Fault
Late Quaternary Activity: Kouma Fault
The Kouma Fault, located at the northern foot of the Mangshan Mountain in Luoyang City, Henan Province, China, is an active fault newly discovered in the field seismic geological s...
Low-temperature thermochronology of fault zones
Low-temperature thermochronology of fault zones
<p>Thermal signatures as well as timing of fault motions can be constrained by thermochronological analyses of fault-zone rocks (e.g., Tagami, 2012, 2019).&#1...
Interference Testing in Reservoirs With Conductive Faults or Fractures
Interference Testing in Reservoirs With Conductive Faults or Fractures
Abstract
This paper addresses interference testing in reservoirs with conductive faults. Both cases of interference tests where the active and observation wells a...
Current active fault distribution and slip rate along the middle section of the Jiali-Chayu fault from Sentinel-1 InSAR observations (2017–2022)
Current active fault distribution and slip rate along the middle section of the Jiali-Chayu fault from Sentinel-1 InSAR observations (2017–2022)
AbstractThe Jiali-Chayu fault, situated on the eastern side of the eastern Himalayan syntaxis, is the southeastern margin of the large strike-slip fault zone of the Jiali Fault. Th...