Effective Volt/var Control for Low Voltage Grids with Bulk Loads

View through CrossRef
This paper investigates the voltage and reactive power control problem in low voltage grids with connected prosumers and bulk loads. The X(U) local control, which maintains the voltage at the feeders’ ends within a predefined band, and its combination with Q-Autarkic customer plants are the most effective and reliable strategies in grids with high prosumer share. However, these strategies may need adaptations to guarantee voltage limit compliance when bulk loads, such as electric vehicle parking garages and community-owned photovoltaic systems, are connected to the low voltage feeders. This paper extends the X(U) local control concept to involve bulk loads in Volt/var control and investigates the resulting load flows in different real low voltage grids. The results show that the extended control arrangement reliably removes all voltage limit violations by deteriorating the effectiveness of the original X(U) local control arrangement: reactive power flows and equipment loading within the low voltage grids are increased.
Title: Effective Volt/var Control for Low Voltage Grids with Bulk Loads
Description:
This paper investigates the voltage and reactive power control problem in low voltage grids with connected prosumers and bulk loads.
The X(U) local control, which maintains the voltage at the feeders’ ends within a predefined band, and its combination with Q-Autarkic customer plants are the most effective and reliable strategies in grids with high prosumer share.
However, these strategies may need adaptations to guarantee voltage limit compliance when bulk loads, such as electric vehicle parking garages and community-owned photovoltaic systems, are connected to the low voltage feeders.
This paper extends the X(U) local control concept to involve bulk loads in Volt/var control and investigates the resulting load flows in different real low voltage grids.
The results show that the extended control arrangement reliably removes all voltage limit violations by deteriorating the effectiveness of the original X(U) local control arrangement: reactive power flows and equipment loading within the low voltage grids are increased.

Related Results

Comparison of Local Volt/var Control Strategies for PV Hosting Capacity Enhancement of Low Voltage Feeders
Comparison of Local Volt/var Control Strategies for PV Hosting Capacity Enhancement of Low Voltage Feeders
The PV hosting capacity of low voltage feeders is restricted by voltage and current limits, and in many cases, voltage limit violations are the limiting factor for photovoltaic int...
Karakterisasi Tiga Jenis Simplisia Jahe yang Tumbuh di Jawa Barat
Karakterisasi Tiga Jenis Simplisia Jahe yang Tumbuh di Jawa Barat
Abstract. Emprit ginger (Zingiber officinale var. Amarum), elephant ginger (Zingiber officinale var. Rosc), and red ginger (Zingiber officinale var. sunti Valeton) are notable biop...
Changes in soil quality on horse paddock trails and the influence of paddock grids
Changes in soil quality on horse paddock trails and the influence of paddock grids
AbstractPaddock trails offer horses the possibility to follow their natural urge to move and to behave interactively in a group association. To create appropriate conditions all ye...
Miscellaneous taxonomic and nomenclatural notes on Microlicia D.Don (Melastomataceae)
Miscellaneous taxonomic and nomenclatural notes on Microlicia D.Don (Melastomataceae)
Continuing the taxonomic and nomenclatural studies of the genus Microlicia, we propose 44 synonyms for 15 Brazilian species. Of these synonyms, 27 are species and 17 are varieties ...
Pengaruh Rangkaian Seri Dan Paralel Terhadap Tegangan Pada Piezoelektrik
Pengaruh Rangkaian Seri Dan Paralel Terhadap Tegangan Pada Piezoelektrik
Abstrak Background: Piezoelektrik didefinisikan sebagai kemampuan yang dimiliki oleh kristal pada bahan-bahan tertentu yang menghasilkan energi listrik jika diberi beban. Pen...
Arbetsförhållanden inom svensk grisproduktion - lantbruksföretagarnas perspektiv
Arbetsförhållanden inom svensk grisproduktion - lantbruksföretagarnas perspektiv
Svensk grisproduktion har genomgått stora förändringar och omstruktureringar under de senaste decennierna, vilket resulterat i allt färre företag. I dagsläget finns det drygt 1100 ...
SISTEM KENDALI PENGISIAN BATERAI PADA PLTS
SISTEM KENDALI PENGISIAN BATERAI PADA PLTS
Kebutuhan energi semakin meningkat energi surya merupakan energi terbarukan yang sangat penting untuk dikembangkan dan dimanfaatkan sebagai sumber energi alternatif untuk mengatasi...
Control and modulation of modular multilevel converters
Control and modulation of modular multilevel converters
The integration of renewable energy sources in the electrical grid is reducing our dependence on fossil fuels. However, to ensure feasibility and reliability of distributed energy ...

Back to Top