Javascript must be enabled to continue!
Shallow-angle needle guide for ultrasound-guided internal jugular venous catheterization: A randomized controlled crossover simulation study (CONSORT) v1
View through CrossRef
Background:Needle guides for ultrasound-guided internal jugular venous catheterization facilitate successful cannulation. The ability of a needle guide to prevent a posterior vein wall injury which may secondarily induce lethal complications, is unknown. Previous studies showed that a shallow angle of approach may reduce the incidence of posterior wall injuries. We developed a novel needle guide with a shallow angle of approach for ultrasound-guided venous catheterization and examined whether this needle guide reduces the incidence of posterior wall injuries compared to a conventional needle guide and free-hand placement in a simulated vein. Methods: This study was a randomized crossover-controlled trial. The primary outcome was the rate of posterior vein wall injuries. Participants had a didactic lecture about three ultrasound-guided techniques using the short-axis out-of-plane approach, including free-hand (P-free), a commercial needle guide (P-com), and a novel needle guide (P-sha). The view inside a simulated vein was recorded during venipuncture. Results: Thirty-five residents participated in this study. Posterior vein wall injuries occurred in 66% using P-free, 60% using P-com, and 0% using P-sha (p< 0.01). There was no significant difference in the incidence of posterior vein wall injuries between P-free and P-com. Conclusions: Use of a shallow angle of approach needle guide resulted in a lower rate of posterior vein injuries during venipuncture of a simulated vein compared with other techniques using a steeper angle techniques.
Title: Shallow-angle needle guide for ultrasound-guided internal jugular venous catheterization: A randomized controlled crossover simulation study (CONSORT) v1
Description:
Background:Needle guides for ultrasound-guided internal jugular venous catheterization facilitate successful cannulation.
The ability of a needle guide to prevent a posterior vein wall injury which may secondarily induce lethal complications, is unknown.
Previous studies showed that a shallow angle of approach may reduce the incidence of posterior wall injuries.
We developed a novel needle guide with a shallow angle of approach for ultrasound-guided venous catheterization and examined whether this needle guide reduces the incidence of posterior wall injuries compared to a conventional needle guide and free-hand placement in a simulated vein.
Methods: This study was a randomized crossover-controlled trial.
The primary outcome was the rate of posterior vein wall injuries.
Participants had a didactic lecture about three ultrasound-guided techniques using the short-axis out-of-plane approach, including free-hand (P-free), a commercial needle guide (P-com), and a novel needle guide (P-sha).
The view inside a simulated vein was recorded during venipuncture.
Results: Thirty-five residents participated in this study.
Posterior vein wall injuries occurred in 66% using P-free, 60% using P-com, and 0% using P-sha (p< 0.
01).
There was no significant difference in the incidence of posterior vein wall injuries between P-free and P-com.
Conclusions: Use of a shallow angle of approach needle guide resulted in a lower rate of posterior vein injuries during venipuncture of a simulated vein compared with other techniques using a steeper angle techniques.
Related Results
Crossover Phenomena in Motor Evoked Potentials During Intraoperative Neurophysiological Monitoring of Cranial Surgeries
Crossover Phenomena in Motor Evoked Potentials During Intraoperative Neurophysiological Monitoring of Cranial Surgeries
Purpose:
Transcranial motor evoked potentials (TcMEPs) are used to assess the corticospinal tract during surgery. Transcranial motor evoked potentials are elicited by p...
Arrhythmia Induced by Right Internal Jugular Vein Catheterization:A Case Report
Arrhythmia Induced by Right Internal Jugular Vein Catheterization:A Case Report
Abstract
Background
Central venous catheterization is crucial for managing critically ill patients, with common sites being the internal jugular, subclavian, and femoral ve...
Concordance with CONSORT-AI guidelines in reporting of randomised controlled trials investigating artificial intelligence in oncology: a systematic review
Concordance with CONSORT-AI guidelines in reporting of randomised controlled trials investigating artificial intelligence in oncology: a systematic review
Background
The advent of artificial intelligence (AI) tools in oncology to support clinical decision-making, reduce physician workload and automate workflow ineff...
Jugular foramen anatomy in lateral skull base paraganglioma surgery
Jugular foramen anatomy in lateral skull base paraganglioma surgery
In this article we present the surgical approaches to the temporal bone paraganglioma based on the anatomical studies. Objective. To detalize the anatomy of the jugular foramen acc...
Long-Axis In-Plane Approach Versus Short-Axis Out-of-Plane Approach for Ultrasound-Guided Central Venous Catheterization in Pediatric Patients: A Randomized Controlled Trial*
Long-Axis In-Plane Approach Versus Short-Axis Out-of-Plane Approach for Ultrasound-Guided Central Venous Catheterization in Pediatric Patients: A Randomized Controlled Trial*
Objectives:
The aim of this study was to compare the occurrence of posterior wall puncture between the long-axis in-plane and the short-axis out-of-plane approaches in ...
Improvement of central vein ultrasound-guided puncture success using a homemade needle guide—a simulation study
Improvement of central vein ultrasound-guided puncture success using a homemade needle guide—a simulation study
Abstract
Background
Out-of-plane (OOP) approach is frequently used for ultrasound-guided insertion of central venous cath...
R1. Improvement of central vein ultrasound guided puncture success using a homemade needle guide. A simulation study
R1. Improvement of central vein ultrasound guided puncture success using a homemade needle guide. A simulation study
Abstract
Background: Out-of-plane (OOP) approach is frequently used for ultrasound-guided insertion of central venous catheter (CVC) owing to its simplicity but does not av...
Needle consideration in umbilical two-port laparoscopic percutaneous extraperitoneal closure for patent processus vaginalis of children: hook-needle or forcep-needle
Needle consideration in umbilical two-port laparoscopic percutaneous extraperitoneal closure for patent processus vaginalis of children: hook-needle or forcep-needle
Abstract
Background
Although umbilical two-port laparoscopic percutaneous extraperitoneal closure for the treatment of processus vaginalis patency o...

