Javascript must be enabled to continue!
ELECTRICAL CHARACTERISTICS OF RAA AND LAA IN 48 H AF CANINE WITH MEA CHIP TECHNIQUE
View through CrossRef
Objectives
To explore electrical characteristics of RAA and LAA in 48 h AF canine with MEA chip technique.
Methods
Twelve adult healthy mongrel canine were randomly divided into two groups:pacing group and control group. The morphology, duration, voltage, discharge frequency and conduction of field potential were recorded.
Results
In AF group, the rhythm of LAA and RAA tissue field potential were irregular, LAA increased in the percent of 15.67%, RAA decreased in the percent of 34.62% than the control group. The voltage of LAA and RAA decreased than the control group, the duration of field potential of LAA and RAA shorted than control group. Electricity impulse represents anisotropic alteration.
Conclusions
MEA is sensitive, long time and stable and local tissue action potential multiple-channel recording mapping system in animal heart slices. The discharge frequency of left atrial appendage increased after 48 h AF, frequency irregularity, the voltage of field potential decreased in atrial appendage, field potential duration increased.
Title: ELECTRICAL CHARACTERISTICS OF RAA AND LAA IN 48 H AF CANINE WITH MEA CHIP TECHNIQUE
Description:
Objectives
To explore electrical characteristics of RAA and LAA in 48 h AF canine with MEA chip technique.
Methods
Twelve adult healthy mongrel canine were randomly divided into two groups:pacing group and control group.
The morphology, duration, voltage, discharge frequency and conduction of field potential were recorded.
Results
In AF group, the rhythm of LAA and RAA tissue field potential were irregular, LAA increased in the percent of 15.
67%, RAA decreased in the percent of 34.
62% than the control group.
The voltage of LAA and RAA decreased than the control group, the duration of field potential of LAA and RAA shorted than control group.
Electricity impulse represents anisotropic alteration.
Conclusions
MEA is sensitive, long time and stable and local tissue action potential multiple-channel recording mapping system in animal heart slices.
The discharge frequency of left atrial appendage increased after 48 h AF, frequency irregularity, the voltage of field potential decreased in atrial appendage, field potential duration increased.
Related Results
Abstract 15625: Left Atrial Appendage Volumetric and Functional Assessment Using Cardiac CT-Derived Three-Dimensional Models
Abstract 15625: Left Atrial Appendage Volumetric and Functional Assessment Using Cardiac CT-Derived Three-Dimensional Models
Introduction:
The left atrial appendage (LAA) is the most common site of thrombus formation in atrial fibrillation (AF) patients who develop strokes, yet its dynamic vo...
Adrenalectomy Performed with the Da Vinci Single-Port Robotic System: A Systematic Review and Pooled Analysis
Adrenalectomy Performed with the Da Vinci Single-Port Robotic System: A Systematic Review and Pooled Analysis
Introduction: The Da Vinci Single-Port (DV-SP) system emerged in 2018 but there is limited evidence on its use and perioperative outcomes for robot-assisted adrenalectomy (RAA). Me...
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract
Despite being the most common subtype of human peripheral T-cell lymphoma (PTCL), PTCL-not otherwise specified (PTCL-NOS) remains a poorly understood diagno...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Surgical repair of tetralogy of Fallot using autologous right atrial appendages: short- to mid-term results
Surgical repair of tetralogy of Fallot using autologous right atrial appendages: short- to mid-term results
Abstract
OBJECTIVES
The prevention of pulmonary insufficiency (PI) is a crucial part of the tetralogy of Fallot ...
Clinical features of retinal amyloid angiopathy with transthyretin Gly83Arg variant
Clinical features of retinal amyloid angiopathy with transthyretin Gly83Arg variant
AIM: To report on the clinical features of patients with retinal amyloid angiopathy (RAA) who were identified to be caused by the transthyretin (TTR) Gly83Arg variant.
METHODS: Cas...
Enhanced CO2 Capture from Flue Gas Using Monoethanolamine and Silica Nanoparticles
Enhanced CO2 Capture from Flue Gas Using Monoethanolamine and Silica Nanoparticles
Abstract
Carbon neutrality is crucial in the fight against climate change, as it refers to a state in which CO2 emissions balance with measures of removal and offset...
Differential densities of cholinergic nerves in canine supraventricular regions of hearts
Differential densities of cholinergic nerves in canine supraventricular regions of hearts
Objective
Cholinergic nerve plays an important role in the induction and maintenance of atrial fibrillation (AF). Cholinergic innervation at supraventricular tiss...

