Adrenalectomy Performed with the Da Vinci Single-Port Robotic System: A Systematic Review and Pooled Analysis

View through CrossRef
Introduction: The Da Vinci Single-Port (DV-SP) system emerged in 2018 but there is limited evidence on its use and perioperative outcomes for robot-assisted adrenalectomy (RAA). Methods: A systematic search was performed through PubMed, Scopus, Ovid, and WoS in December 2024. A PICO framework was used. Population: adult patients with adrenal masses; Intervention: DV-SP RAA; Outcomes: feasibility, reproducibility and safety of DV-SP RAA. A total of five retrospective studies involving 342 patients were included. The quantitative analysis was conducted using a random-effect model or a fixed-effect model as appropriate. A risk of bias assessment for non-randomized comparative studies and case series was performed. Results: The pooled mean operative time was 92.5 min (95% confidence interval [CI] 71.2, 113.9, p I2 = 0%, four studies), and the mean estimated blood loss (EBL) was 26.5 mL (95%CI −8.1, 61.2, I2 = 98.2%, three studies). Most of the procedures were completed with a single incision, though some required additional port placement, with a proportion of 9% (95%CI 0, 29, I2 = 71.7%, five studies). Perioperative complications were rare (0%, 95% CI 0, 4, I2 = 0%, five studies). Two studies comparing DV-SP and DV multi-port (MP) found no significant differences in complications. One study compared DV-SP RAA to DV Si or Xi single-access procedures. DV-SP showed improved operative techniques and better cosmetic outcomes. Limitations of this study are small sample size and potential selection bias due to smaller masses in the DV-SP RAA group. Conclusions: DV-SP RAA is a promising approach, offering reduced operative time, low EBL, and excellent cosmetic results. This study shows that DV-SP RAA seems reproducible, feasible, and safe. Limitation of the included studies are small sample size and selection bias, which limits the generalizability of the results. Randomized comparative studies between DV-SP and MP RAA are needed to further validate these findings.
Title: Adrenalectomy Performed with the Da Vinci Single-Port Robotic System: A Systematic Review and Pooled Analysis
Description:
Introduction: The Da Vinci Single-Port (DV-SP) system emerged in 2018 but there is limited evidence on its use and perioperative outcomes for robot-assisted adrenalectomy (RAA).
Methods: A systematic search was performed through PubMed, Scopus, Ovid, and WoS in December 2024.
A PICO framework was used.
Population: adult patients with adrenal masses; Intervention: DV-SP RAA; Outcomes: feasibility, reproducibility and safety of DV-SP RAA.
A total of five retrospective studies involving 342 patients were included.
The quantitative analysis was conducted using a random-effect model or a fixed-effect model as appropriate.
A risk of bias assessment for non-randomized comparative studies and case series was performed.
Results: The pooled mean operative time was 92.
5 min (95% confidence interval [CI] 71.
2, 113.
9, p I2 = 0%, four studies), and the mean estimated blood loss (EBL) was 26.
5 mL (95%CI −8.
1, 61.
2, I2 = 98.
2%, three studies).
Most of the procedures were completed with a single incision, though some required additional port placement, with a proportion of 9% (95%CI 0, 29, I2 = 71.
7%, five studies).
Perioperative complications were rare (0%, 95% CI 0, 4, I2 = 0%, five studies).
Two studies comparing DV-SP and DV multi-port (MP) found no significant differences in complications.
One study compared DV-SP RAA to DV Si or Xi single-access procedures.
DV-SP showed improved operative techniques and better cosmetic outcomes.
Limitations of this study are small sample size and potential selection bias due to smaller masses in the DV-SP RAA group.
Conclusions: DV-SP RAA is a promising approach, offering reduced operative time, low EBL, and excellent cosmetic results.
This study shows that DV-SP RAA seems reproducible, feasible, and safe.
Limitation of the included studies are small sample size and selection bias, which limits the generalizability of the results.
Randomized comparative studies between DV-SP and MP RAA are needed to further validate these findings.

Related Results

Endoscopic and Robotic Assisted Transvaginal Hysterectomy: A Feasibility Study
Endoscopic and Robotic Assisted Transvaginal Hysterectomy: A Feasibility Study
Purpose: To perform a feasibility study of the novel approach “transvaginal natural orifice transluminal endoscopic surgery” (vNOTES) with Da-Vinci robotic assistance. The primary ...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Robotic Surgery
Robotic Surgery
Robots have revolutionized industrial production, from automobiles to pharmaceutical manufacturing, and offer an exciting, novel approach to surgical diseases. Robots employed in s...
Robotic Surgery
Robotic Surgery
Robots have revolutionized industrial production, from automobiles to pharmaceutical manufacturing, and offer an exciting, novel approach to surgical diseases. Robots employed in s...
Study of Port Tariff Structure and Port Pricing Approach
Study of Port Tariff Structure and Port Pricing Approach
In order to support National Logistics System continuity there are at least three (3) main components that should synergize well, namely the sea side (sea transport), the land side...
Robotic-Assisted Retroperitoneoscopic Adrenalectomy: Making a Good Procedure Even Better
Robotic-Assisted Retroperitoneoscopic Adrenalectomy: Making a Good Procedure Even Better
Posterior retroperitoneoscopic adrenalectomy (PRA) is a minimally invasive procedure offering several advantages over a transabdominal laparoscopic operation. The three-dimensional...
SAT-469 Update on the Use of Robotic Surgery and Artificial Intelligence for Adrenal Tumors
SAT-469 Update on the Use of Robotic Surgery and Artificial Intelligence for Adrenal Tumors
Abstract Disclosure: H.M. Heshmati: None. N. Zameni: None. Background: Robotic surgery is quickly replacing traditional surgery performed by hum...

Back to Top